Search:

Type: Posts; User: R600a

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    3
    Views
    51

    That's a mess. I have a friend who has one like...

    That's a mess. I have a friend who has one like that. It is disabled until they feel safe enough to let is come in the house and replace it.

    Sent from the Okie state usin Tapatalk
  2. Replies
    3
    Views
    51

    I am surprised you can hear anything over the...

    I am surprised you can hear anything over the blower.

    Sent from the Okie state usin Tapatalk
  3. Replies
    5
    Views
    1,406

    I sent the boss's son back to make the decision...

    I sent the boss's son back to make the decision on this and he decided it needed a new vent pipe and inducer motor. Well I don't agree with him it's not my license on the line. So I pulled out the...
  4. Thats interesting. Sent from the Okie state...

    Thats interesting.

    Sent from the Okie state usin Tapatalk
  5. Replies
    17
    Views
    281

    Oh man why did you have to start this thread...

    Oh man why did you have to start this thread don't you know it's going to cost me a lot of money now I've got to buy one too. [emoji1787]

    Sent from the Okie state usin Tapatalk
  6. Replies
    16
    Views
    465

    It sounds like you are describing a poorly...

    It sounds like you are describing a poorly supported coil. It may need support under the coil box like unistrut or some 2x4s. some overall pictures that show the entire setup might be helpful.
    ...
  7. Replies
    21
    Views
    492

    That relief pipe sure looks like a coper 90 on...

    That relief pipe sure looks like a coper 90 on CPVC glued with PVC glue. That is 3 layers of incompatibility.

    Sent from the Okie state usin Tapatalk
  8. Replies
    6
    Views
    212

    I heard that the best refrigeration guy in town...

    I heard that the best refrigeration guy in town went to school there.

    Sent from the Okie state usin Tapatalk
  9. Replies
    15
    Views
    321

    I have a new old stock mercury thermostat you can...

    I have a new old stock mercury thermostat you can upgrade to.

    Sent from the Okie state usin Tapatalk
  10. Replies
    6
    Views
    212

    It's good to know there's more than one of us on...

    It's good to know there's more than one of us on here. [emoji16]
    If you're 405 area code I'm just half hour north of the border so I'm pretty sure you got a lot more of the storm. We don't really...
  11. Replies
    6
    Views
    212

    Are you a fellow Okie? Sent from the Okie...

    Are you a fellow Okie?

    Sent from the Okie state usin Tapatalk
  12. Replies
    30
    Views
    940

    The 4 inch conduit gets to be a real pain....

    The 4 inch conduit gets to be a real pain. [emoji16]

    Sent from the Okie state usin Tapatalk
  13. Replies
    30
    Views
    940

    Oh wow. I didn't know that. Sent from the Okie...

    Oh wow. I didn't know that.

    Sent from the Okie state usin Tapatalk
  14. Replies
    30
    Views
    940

    Lets run some #10 THHN thermostat wire. [emoji16]...

    Lets run some #10 THHN thermostat wire. [emoji16] Ok maybe not.

    Sent from the Okie state usin Tapatalk
  15. Thread: Invalid file?

    by R600a
    Replies
    6
    Views
    170

    Interesting. I wish I understood computer stuff a...

    Interesting. I wish I understood computer stuff a bit better. My aunt has a master's degree in computer science and I can usually figure out how to post on a forum. [emoji1787]
    Sorry to interrupt i...
  16. Thread: Invalid file?

    by R600a
    Replies
    6
    Views
    170

    @Robb M. What language is that? [emoji16] Edit:...

    @Robb M. What language is that? [emoji16]
    Edit: Poof! It evaporated! [emoji1787]
    I didn't think that was intended for posting.
    Sent from the Okie state usin Tapatalk
  17. Replies
    30
    Views
    940

    Is that even legal? And if it is is it smart. I...

    Is that even legal? And if it is is it smart.
    I would much rather repair damaged stat wire than chase my tail over induced voltage faults or replace low voltage components that get cooked by 240v....
  18. Replies
    30
    Views
    940

    They have steel blades for that. Sent from the...

    They have steel blades for that.

    Sent from the Okie state usin Tapatalk
  19. Also lazy yellow flame sounds like lack of oxygen...

    Also lazy yellow flame sounds like lack of oxygen so with as little information as I have it could be that your home is getting low on oxygen if this is a ventless or a malfunctioning vented heater....
  20. Sounds like it probably just needs cleaned. most...

    Sounds like it probably just needs cleaned. most techs and companies don't like to mess with them because they consider them cheap junk which is basically what they are. Myself I do service them....
  21. That made it all made sense to me. Constant...

    That made it all made sense to me. Constant crankcase heat it is i guess.

    Sent from the Okie state usin Tapatalk
  22. Replies
    12
    Views
    432

    I would look at other chemicals in your house...

    I would look at other chemicals in your house like pest control chemicals and cleaners because R600 and gas are some of the least toxic chemicals in your home. One common pest control spray in my...
  23. Replies
    11
    Views
    307

    Hmm i guess it is either mint chip or mold chip....

    Hmm i guess it is either mint chip or mold chip.

    Sent from the Okie state usin Tapatalk
  24. Replies
    11
    Views
    307

    Maybe moldy ice cream. [emoji16][emoji510] ...

    Maybe moldy ice cream. [emoji16][emoji510]

    Sent from the Okie state usin Tapatalk
  25. Replies
    14
    Views
    334

    And set it up to run on the cold end of the range...

    And set it up to run on the cold end of the range to produce more condensate to wash contaminants away.

    Sent from the Okie state usin Tapatalk
  26. Thanks i am reading that now. Sent from the...

    Thanks i am reading that now.

    Sent from the Okie state usin Tapatalk
  27. Replies
    10
    Views
    303

    Same here and we get insane rain sometimes. ...

    Same here and we get insane rain sometimes.

    Sent from the Okie state usin Tapatalk
  28. Replies
    10
    Views
    303

    Oh okay. I've never seen that before the one on...

    Oh okay. I've never seen that before the one on the fresh air pipe is important though. Without looking at the installation location I don't know why there would be a 90 on it but it would probably...
  29. I am wondering what causes there to be a pressure...

    I am wondering what causes there to be a pressure differential that allows the refrigerant to migrate into the oil when the oil is warmer than the evaporator? I'm starting to understand that it...
  30. I feel like there is something I don't know about...

    I feel like there is something I don't know about here. What causes the pressure differential between the oil and the refrigerant?

    Sent from the Okie state usin Tapatalk
  31. Replies
    10
    Views
    303

    I have not seen a problem with that and the 90...

    I have not seen a problem with that and the 90 on the end of the fresh air pipe is usually important.

    Sent from the Okie state usin Tapatalk
  32. Replies
    30
    Views
    940

    It doesn't go straight into the control...

    It doesn't go straight into the control compartment but I have connected conduit to a train for the thermostat wire. Then I run the thermostat wire looped back through into the control compartment...
  33. Replies
    12
    Views
    432

    If you are having symptoms that you believe to be...

    If you are having symptoms that you believe to be related to r600a refrigerant you should be much more worried about natural gas or propane leaks if you have such in your house because refrigerators...
  34. Replies
    30
    Views
    940

    It may be tough but it doesn't have fittings for...

    It may be tough but it doesn't have fittings for connecting to the condenser.

    Sent from the Okie state usin Tapatalk
  35. I am not familiar with that controller but if i...

    I am not familiar with that controller but if i am not mistaken all current fujitsu units come with a wifi module built in so you should be able to use the Fujitsu FGLair app without any added...
  36. I have often wondered about putting a temperature...

    I have often wondered about putting a temperature switch on the CCH to only run it below 80 or something like that.

    Sent from the Okie state usin Tapatalk
  37. Me too but sadly manufacturers don't care if it...

    Me too but sadly manufacturers don't care if it makes it out of warranty.

    Sent from the Okie state usin Tapatalk
  38. I believe a crank case heater reduces the seer...

    I believe a crank case heater reduces the seer rating.

    Sent from the Okie state usin Tapatalk
  39. Crank case heater. They warm the oil to drive...

    Crank case heater.
    They warm the oil to drive out the refrigerant.

    Sent from the Okie state usin Tapatalk
  40. Replies
    30
    Views
    940

    No i have a cheap digital pen soldering iron and...

    No i have a cheap digital pen soldering iron and an extension cord and of course good old lead solder.
    ...
  41. Replies
    30
    Views
    940

    I do that any chance I get. Also if i repair a...

    I do that any chance I get. Also if i repair a thermostat wire I solder and heat shrink it and run conduit to make my repair permanent.

    Sent from the Okie state usin Tapatalk
  42. Those adaptive defrost boards can be finicky. If...

    Those adaptive defrost boards can be finicky.
    If the air duct got clogged from icing up when the door got left open a crack or something then you will have to defrost it manually.

    Sent from the...
  43. Is air actually getting to the fridge section?...

    Is air actually getting to the fridge section?
    It sounds like a defrost problem to me. Is the defrost timer mechanical or a board?

    Sent from the Okie state usin Tapatalk
  44. Payne for one. Sent from the Okie state usin...

    Payne for one.

    Sent from the Okie state usin Tapatalk
  45. Just buy one of the brands that has them. We sell...

    Just buy one of the brands that has them. We sell Armstrong and they have high and low pressure switches. We sold champion and they had high pressure switches.

    Sent from the Okie state usin...
  46. Just use condensate pump tablets. But if the...

    Just use condensate pump tablets.
    But if the tubing is accessible just replace it. The pumps i have been using have a roll included in the box.

    Sent from the Okie state usin Tapatalk
  47. I also use it for checking the pan temp when i am...

    I also use it for checking the pan temp when i am making burgers. It is repeatable so even if it isn't accurate it still puts a number on the temp that either did or didn't work well for me.

    Sent...
  48. I carry a flute and a harbor freight infrared...

    I carry a flute and a harbor freight infrared thermometer and they are within two degrees of each other so the harbor freight one is up to 22 off when the fluke is only 20 off. Infrared...
  49. I think it means talk to text fails again....

    I think it means talk to text fails again. [emoji16]

    Sent from the Okie state usin Tapatalk
  50. In my opinion if it's 10 past years old for the...

    In my opinion if it's 10 past years old for the price of a new pump and hose I'd replace them both. At the same time in a basement there's probably not much risk of water damage and with your tub...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4