Search:

Type: Posts; User: pacnw

Page 1 of 20 1 2 3 4

Search: Search took 0.18 seconds.

  1. Thread: Heat Pump/Aux

    by pacnw
    Replies
    14
    Views
    322

    The new ones are easy to set up!!!!

    The new ones are easy to set up!!!!
  2. Thread: Heat Pump/Aux

    by pacnw
    Replies
    14
    Views
    322

    That makes no sense!!!! 25° is 25°. The only...

    That makes no sense!!!!

    25° is 25°. The only difference may be moisture in the air, but that can change throughout the day as well.

    As I mentioned in my reply to kdean1, the info you need CAN...
  3. Thread: Heat Pump/Aux

    by pacnw
    Replies
    14
    Views
    322

    This is a dual fuel stat. Not sure what you...

    This is a dual fuel stat.

    Not sure what you are looking at, but the paperwork that comes with these, and available online, is about worthless.

    The set up info is all contained in the stat. On...
  4. Thread: Heat Pump/Aux

    by pacnw
    Replies
    14
    Views
    322

    First, with a heat pump you find your comfortable...

    First, with a heat pump you find your comfortable temp and leave it there, no setback or changes.

    When you use a setback, you lose money.

    If you have the install manual it tells you how to do...
  5. Replies
    3
    Views
    169

    Pictures? If this has a filter, then it SHOULD...

    Pictures?

    If this has a filter, then it SHOULD be a return and the air SHOULD be sucked into it and NOT blowing out.
    With that said, I would NOT put a return in a closet, especially if it can be...
  6. Thread: Communist CA

    by pacnw
    Replies
    9
    Views
    191

    Can't see much when you head is up your a$$!!!!...

    Can't see much when you head is up your
    a$$!!!!

    Besides, the politicians won't be affected.
  7. Y &G may not have been shorted. Many times,...

    Y &G may not have been shorted. Many times, depending on the wiring schematic, Y is a dummy terminal.
    They are "connected" in the stat.

    NEST is junk to start with. If it's doing funky things,...
  8. Thread: Communist CA

    by pacnw
    Replies
    9
    Views
    191

    They are fricking morons!!!!!!! They have not...

    They are fricking morons!!!!!!!

    They have not got enough power for what they have now, what makes them think they can "make" more?
  9. Maybe the smoke was the oil burning off.

    Maybe the smoke was the oil burning off.
  10. Replies
    23
    Views
    942

    Do you have any paperwork that shows the model...

    Do you have any paperwork that shows the model number?

    Do NOT do any of those other dangerous and unprofessional suggestions!!!!!

    Without doing other things, changing the stat to 1 stage is not...
  11. I'm guessing the air filter is just in the photo,...

    I'm guessing the air filter is just in the photo, upper right corner.

    Still very questionable install on at least these 2 issues.
  12. https://hvac-talk.com/vbb/showthread.php?2213525-H...

    https://hvac-talk.com/vbb/showthread.php?2213525-How-Increase-fan-speed-in-air-handler-furnace

    Sound familiar. :whistle:
  13. These MUST be wired in a specific pattern and...

    These MUST be wired in a specific pattern and MUST be used in specific numbers!!!!!

    Carrier kind of screwed the end user with this control set up.
  14. I have a suspicion that some "genius" had to...

    I have a suspicion that some "genius" had to clean that out and cut it not knowing the original design of the pipe in pie set up.

    Then it got repiped as we see it using that sanitary tee, cpvc...
  15. Thread: Change fan speed

    by pacnw
    Replies
    8
    Views
    272

    120,000 btu, 96% efficient furnace for a 1700sq'...

    120,000 btu, 96% efficient furnace for a 1700sq' house!!!!!

    No wonder it short cycles.

    There was no load calc done, unless you live in Antarctica and leave the windows and doors open.
  16. Replies
    3
    Views
    169

    If air comes out, it is a supply. There should...

    If air comes out, it is a supply.

    There should NOT be a return in the closet.

    There could be a supply in the closet and sound like there is from your description.

    If it is too hot or cold...
  17. Read the instruction. If you can't answer your...

    Read the instruction.

    If you can't answer your own question then you are in over your head.

    As suggested call Honeywell for an explanation or a professional to properly install and set up a...
  18. Thread: Change fan speed

    by pacnw
    Replies
    8
    Views
    272

    The a/c coil is 5 tons!!!!!! Seems quite...

    The a/c coil is 5 tons!!!!!!

    Seems quite oversized for the highlighted portion of your post.

    Post the furnace model number, it's located either on a sticker on the right outside of the furnace...
  19. Why would you use that tee?

    Why would you use that tee?
  20. Replies
    4
    Views
    214

    Sounds like the need to call a professional.

    Sounds like the need to call a professional.
  21. Thread: Change fan speed

    by pacnw
    Replies
    8
    Views
    272

    You don't. Also, the model number you provided...

    You don't.

    Also, the model number you provided is for the a/c indoor coil, not the furnace.
  22. Replies
    13
    Views
    391

    I'm going through the same thing. It's tough,...

    I'm going through the same thing.

    It's tough, for sure!!!
  23. Might be a good read, I did not read it all. ...

    Might be a good read, I did not read it all.

    https://hvac-talk.com/vbb/showthread.php?1654511-Carrier-58MVC-Inducer-Faults-and-occasional-Limit-Fault
  24. Not sure if it's automatic or it has to be...

    Not sure if it's automatic or it has to be registered.
    If you did not register it and nobody else did, it may revert to a lesser time period on all but the heat exchanger.
  25. Full model and serial number, please. Helps...

    Full model and serial number, please.

    Helps us, or your tech, to find out things.
  26. The the OP, You stated you were given a quote...

    The the OP,

    You stated you were given a quote for the repair andaccepted the repair quote.

    Buyer's remorse?

    If you thought it was wrong, don't accept and call someone else. Price shop.
  27. Do you think they care? It's thousands cheaper...

    Do you think they care?
    It's thousands cheaper what could go wrong?
  28. All the other posts are probably correct to look...

    All the other posts are probably correct to look into first.

    Could be, again not likely with what you described, the unit is locked out below 30° via a setting in the controls.
  29. At least I know how to do it, unlike your...

    At least I know how to do it, unlike your bonehead contractors.

    At least I can read and understand the rules when signing up for a site/service. Hell, for people like you the site even puts it in...
  30. It won't void any warranty. It's secret on...

    It won't void any warranty.

    It's secret on this site due to the no DIY rules. Also, as I stated, if your tech(s) can't think of this on their own they may not be capable of doing it correctly.
  31. While it is not a Trane, so far as I know, fix,...

    While it is not a Trane, so far as I know, fix, it is in no way a hillbilly fix.
  32. Replies
    8
    Views
    296

    It is less about the set temperature and more...

    It is less about the set temperature and more about the supply air temp.

    Too low of supply temp is what causes the condensation and allows it to remain.

    If the location does not experience...
  33. Thread: Cad Ohms

    by pacnw
    Replies
    25
    Views
    653

    If you don't install a back up heat source in the...

    If you don't install a back up heat source in the furnace air handler portion(electric strip heat or fuel) than if you allow the heat pump to operate below the point it needs to go into defrost the...
  34. Replies
    6
    Views
    391

    "Fresh" air is probably the incorrect term to...

    "Fresh" air is probably the incorrect term to use. Depending on the home design, it is probably ventilation air or better yet, make up air.

    Before the need to worry about how much energy was used...
  35. While this may be harsh, if they don't know what...

    While this may be harsh, if they don't know what BaldLoonie is suggesting then it is probably best they not do it.

    I think I know what he is suggesting and I have an idea what I would do, but I...
  36. Replies
    1
    Views
    215

    Best to call a professional to sort it out. ...

    Best to call a professional to sort it out.

    While there is a usually a color to terminal wiring used, it can be whatever someone wants. different color wire, all the same color, splices, etc.
    ...
  37. Replies
    5
    Views
    419

    :ditto:

    :ditto:
  38. Replies
    16
    Views
    561

    Highly doubt a crack in the hx. Most likely...

    Highly doubt a crack in the hx.

    Most likely the secondary issue.

    Could be other issues with the furnace, like vstech stated.
  39. From what I see, that appears to be correct,...

    From what I see, that appears to be correct, continuous fan is NOT adjustable.
  40. Thread: Ac freezing

    by pacnw
    Replies
    7
    Views
    305

    Yes there is.

    Yes there is.
  41. Replies
    9
    Views
    405

    You wrote that you installed it. Did you or did a...

    You wrote that you installed it. Did you or did a company do this?

    What is code 33?

    While you may work on dishwashers, this is not a dishwasher and incorrectly "playing" with something can have...
  42. Replies
    14
    Views
    583

    Have they checked into this?

    Have they checked into this?
  43. Replies
    6
    Views
    326

    Provide numbers that would help us help you....

    Provide numbers that would help us help you.
    Indoor temp
    Outdoor temp
    Airflow
    Metering devices(you say no indoor expansion valve, so piston inside?)
    Mode of operation numbers were taken in...
  44. Replies
    10
    Views
    453

    If it is failing the tech has to base that on...

    If it is failing the tech has to base that on something. That documentation should be good enough for warranty and the claim against the power company.

    Do you know that the power company will do...
  45. Replies
    14
    Views
    583

    Did it start after the Ecobee was installed? If...

    Did it start after the Ecobee was installed? If so, I would start there.

    Provide model number of the Coleman furnace.
  46. Replies
    6
    Views
    704

    New inducer, new control board and new pressure...

    New inducer, new control board and new pressure switches has remedied every one we have experienced issues with, and those we did without issues.
  47. Replies
    12
    Views
    354

    I would NOT use "CIRC" on the Honeywell stats,...

    I would NOT use "CIRC" on the Honeywell stats, personally. I think they are the dumbest setting. Either you want the fan on or off, but why start and stop the motor every hour? It's like the cars...
  48. How are the zones controlled?

    How are the zones controlled?
  49. I'm thinking maybe 2 fan speeds energized at the...

    I'm thinking maybe 2 fan speeds energized at the same time, heat and cooling?
  50. Replies
    8
    Views
    289

    What troubleshooting have you done? Nothing...

    What troubleshooting have you done?

    Nothing posted would indicate you are an hvac tech.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4