    Checking compressor superheat and evaporator...

    Checking compressor superheat and evaporator superheat are two different things
  2. Replies
    15
    Views
    135

    I've got one of those by Russell 3...

    I've got one of those by Russell 3 semi-hermetics.
    Came out of a Denny's.
  3. Replies
    15
    Views
    135

    It most likely has a receiver so typically we...

    It most likely has a receiver so typically we aren't concerned about sub cooling.
  4. Replies
    17
    Views
    290

    BIG time ! Actually you did pretty good if you...

    BIG time !
    Actually you did pretty good if you got $ 1.30 with the end sheets.
    Here's the current scrap pricing.
    Clean Alum/Copper is at $ 1.50
  5. Replies
    17
    Views
    290

    Those clean coils as in end sheet removed ?

    Those clean coils as in end sheet removed ?
  6. That is correct but we still don't have a answer...

    That is correct but we still don't have a answer to your original question.
    Why do we call a single phase condensing unit connected to two opposite phases of a three phase system single phase ?
  7. Because the phases are out of phase from one...

    Because the phases are out of phase from one another. Be it two opposite phases from 3 phases or 1 phase split from single phase .
  8. Maybe this will help

    Maybe this will help
  9. Terry that's a interesting question. If I'm...

    Terry that's a interesting question.
    If I'm understanding correctly your question is this.
    How does a residential 208/230 volt residential condensing unit work off of opposite phases on three phase...
  10. Yep

    Yep
  11. Yeah I should have clarified that the single...

    Yeah I should have clarified that the single phase could be coming from a 3 phase system and a transformer is used to get the single phase in residential.
  12. .

    .
  13. YES

    YES
  14. Replies
    29
    Views
    764

    But I thought it was a additional expense ?

    But I thought it was a additional expense ?
  15. Replies
    16
    Views
    422

    Yeah I'm a ragy guy as well although I've got the...

    Yeah I'm a ragy guy as well although I've got the others.
    One thing I don't like about wet rags is it takes more heat to do the weld.
  16. Replies
    29
    Views
    764

    By law it's your freon/refrigerant if they remove...

    By law it's your freon/refrigerant if they remove it.
  17. Replies
    29
    Views
    764

    Thank you that makes more sense. Your prior post...

    Thank you that makes more sense.
    Your prior post said 10lbs not 10 dollars.
  18. Replies
    29
    Views
    764

    Here's where it's confusing. If you need 7 lbs....

    Here's where it's confusing.
    If you need 7 lbs. per the contractor.
    Home warranty covers 10 lbs.
    How does that make you pay anything out of pocket ?
  19. Replies
    29
    Views
    764

    Clear as mud 😜

    Clear as mud 😜
  20. Replies
    29
    Views
    764

    Wait are you saying your warranty company will...

    Wait are you saying your warranty company will pay for 10lbs ?
    That's not what's been stated here.
  21. Replies
    29
    Views
    764

    Are you saying they sell it to the homeowner on...

    Are you saying they sell it to the homeowner on the side ?
    As in sorry that's not covered ?
  22. Replies
    29
    Views
    764

    I think home warranty would say go for it !...

    I think home warranty would say go for it !
    Thanks for saving us money 😉
  23. Replies
    80
    Views
    3,184

    Why did I think you were joking ? I've got a...

    Why did I think you were joking ? I've got a 220volt plasma cutter I use for heavy metal but never considered using it for something like this.
    Can a little knowledge be dangerous 🙄
  24. Replies
    80
    Views
    3,184

    How about those new blower housing's doesn't the...

    How about those new blower housing's doesn't the plastic stink profusely from the sparks ? 😜
  25. Replies
    47
    Views
    805

    And that's why I hate Dork 🤣

    And that's why I hate Dork 🤣
  26. Replies
    80
    Views
    3,184

    I do wrap some of my driver shafts with...

    I do wrap some of my driver shafts with electrical tape to help prevent accidental arcing in tight quarters.
    As for knockouts yes Trane does seem to use heavier gauge metal on their cabinets.
    Take...
  27. Replies
    47
    Views
    805

    But he stated they even used a OEM motor.

    But he stated they even used a OEM motor.
  28. Replies
    47
    Views
    805

    I would wire it exactly as the diagram shows.

    I would wire it exactly as the diagram shows.
  29. Replies
    47
    Views
    805

    Good Band-Aid but the problem should be...

    Good Band-Aid but the problem should be corrected.
    They are good for wind conditions.
  30. Would that be the centrifugal switches ?

    Would that be the centrifugal switches ?
  31. Replies
    47
    Views
    805

    Those two fans have to start simultaneously or...

    Those two fans have to start simultaneously or you'll have the issue you're having.
    If one fan starts first before the other it will pull air in reverse through the second one causing it to start...
  32. Replies
    47
    Views
    805

    I would not leave it that way. You want to use...

    I would not leave it that way.
    You want to use the independent outdoor fan relay/contactor.
    It is a separate power circuit.
  33. Replies
    47
    Views
    805

    Ohhh wait that's 14824031

    Ohhh wait that's 14824031
  34. Replies
    47
    Views
    805

    .

    .
  35. Replies
    47
    Views
    805

    It providing one lag of the power to each cap....

    It providing one lag of the power to each cap.
    With that one lag of power being #117 ( Yellow )
    Black would be your common lag.
  36. Replies
    47
    Views
    805

    Commercial split or package ? Model number ?

    Commercial split or package ?
    Model number ?
  37. Replies
    47
    Views
    805

    How many fans are on this ?

    How many fans are on this ?
  38. You might be lucky they didn't tell you the...

    You might be lucky they didn't tell you the condenser needs replaced.
    That happens a lot believe it or not.
  39. Replies
    52
    Views
    998

    Don't worry he'll find it eventually.

    Don't worry he'll find it eventually.
  40. Replies
    10
    Views
    287

    Trust me I'm right at your heels ! Ironically...

    Trust me I'm right at your heels !
    Ironically your avatar looks so young 🤔
  41. Replies
    10
    Views
    287

    Well make up your mind already 😆

    Well make up your mind already 😆
  42. If we only had a compressor model number:gah:

    If we only had a compressor model number:gah:
  43. Replies
    10
    Views
    287

    Ball park would be to use RLA's for both units...

    Ball park would be to use RLA's for both units and convert to kilowatts.
    Find your local energy company rate per kilowatt.
  44. Yep he should have higher then normal head...

    Yep he should have higher then normal head pressure.
    But it might be one piece in the puzzle why it isn't.
    I'm not sure how the circuits in those coils are divided up.
    I'll assume top half bottom...
  45. It's a triple coil that's probably never been...

    It's a triple coil that's probably never been split and cleaned.
  46. Did you check the TD across the condenser ?

    Did you check the TD across the condenser ?
  47. Low sub-cooling would be low charge in the...

    Low sub-cooling would be low charge in the condenser.
  48. What's the possibly your reversing valve is...

    What's the possibly your reversing valve is bypassing some low side pressure ?
  49. Why is the discharge pressure so low for that...

    Why is the discharge pressure so low for that ambient ?
  50. Yep that's what I'm seeing, well close enough

    Yep that's what I'm seeing, well close enough