Search:

Type: Posts; User: beenthere

Search: Search took 0.14 seconds.

  1. Replies
    11
    Views
    1,206

    When you had to add some last year, was it...

    When you had to add some last year, was it running in a vacuum.

    Those readings indicate some non condensibles.

    I'd also clean the coils while I was at it.

    So recover, new filter, deep vac...
  2. Replies
    11
    Views
    1,206

    In order to get a good answer that info is...

    In order to get a good answer that info is needed.

    indoor wb, and db
    outdoor db
    suction line pressure and temp
    liquid line pressure and temp
    metering device
    coil delta
    brand, model.
  3. Replies
    11
    Views
    1,206

    Without outdoor ambient that doesn't tell us...

    Without outdoor ambient that doesn't tell us anything.
    Same with suction, need to know indoor bd, and wb.

    But at 270 head, it better be real hot outside.

    Have you serviced it lately, like...
Results 1 to 3 of 3

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.