Search:

Type: Posts; User: Pnasty

Page 1 of 17 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    24
    Views
    353

    I didn’t mean to imply to charge the unit with...

    I didn’t mean to imply to charge the unit with the 290, I was thinking a hose-less charging.
  2. Replies
    6
    Views
    186

    Do you not have patience for someone who is...

    Do you not have patience for someone who is speaking English as a second language? Download the Copeland app and you won’t need to rely on other humans for answers.
  3. Replies
    24
    Views
    353

    My vote is 290 and an open flame.

    My vote is 290 and an open flame.
  4. If those drawings are anyway close to accurate, I...

    If those drawings are anyway close to accurate, I count 6 tees piped improperly. I can’t really make out the the piping arrangement at the “manifolds”. My brain is shot spent to much time working...
  5. Thread: Moircraft

    by Pnasty
    Replies
    5
    Views
    196

    There’s only one way that goes in, you should...

    There’s only one way that goes in, you should prolly hire a pro to put it in for you.
  6. Replies
    3
    Views
    349

    You need to have the rundawg library card.

    You need to have the rundawg library card.
  7. The Canadian electrical code book should be able...

    The Canadian electrical code book should be able to tell you. Local municipalities may have stricter guidelines.
  8. Replies
    3
    Views
    219

    You posted to the homeowner section. Click the...

    You posted to the homeowner section. Click the black triangle in the bottom left of your post and request it moved to the appropriate section. Your profile states you are a homeowner. If this is...
  9. Put your hand on the liquid line, does it feel...

    Put your hand on the liquid line, does it feel cooler or warmer than ambient. Then figure out if your temperature sensor is accurate.
  10. Is the unit calling for blower or cooling or...

    Is the unit calling for blower or cooling or heating? You said you turned the unit on but what does the thermostat want to do?
  11. Thread: Poor Goodman..

    by Pnasty
    Replies
    10
    Views
    674

    It’s a millennial thing not to put diffusers on...

    It’s a millennial thing not to put diffusers on ductwork.
  12. Replies
    9
    Views
    676

    What you can’t see is the condenser is folded...

    What you can’t see is the condenser is folded inwards. It is now a split coil. This guy hires an HVAC sub to accomplish this new pad.
  13. Replies
    5
    Views
    229

    This has homeowner written all over it.

    This has homeowner written all over it.
  14. Replies
    8
    Views
    447

    Cool story bro

    Cool story bro
  15. Condensate pimp will save you head aches. It will...

    Condensate pimp will save you head aches. It will not be any louder than the air handler.
  16. It could be undersized or it could be low on...

    It could be undersized or it could be low on refrigerant. If it’s never reaching a 5° set point, and 12-15° is adequate for your operation why not turn the thermostat up? Maybe you have a defrost...
  17. Replies
    1
    Views
    145

    I’m not an engineer and not that familiar with...

    I’m not an engineer and not that familiar with construction practices, but I don’t think you can compromise a joist with that large of a hole without severe repercussions.

    What does that duct...
  18. Replies
    2
    Views
    330

    To add on; the back plate must be changed. You...

    To add on; the back plate must be changed. You may not have problems right away but you will have problems down the road. I’ve seen a couple of restaurants, that have 4-6 of the same model...
  19. Poll: The problem was he used a map gas torch. There’s...

    The problem was he used a map gas torch. There’s no way you can braze with that on anything larger than 1/4-3/8”. I used it being lazy a couple weeks ago on 3/8” and regretted being lazy.
  20. Replies
    10
    Views
    263

    They are super fun in the middle of summer, unit...

    They are super fun in the middle of summer, unit low on charge, dirty filter and ices an 1” thick back to the compressor.
  21. Replies
    11
    Views
    267

    Pushing a contactor is like flipping a light...

    Pushing a contactor is like flipping a light switch with when the light bulb isn’t there, It doesn’t tell you anything.
  22. Replies
    7
    Views
    224

    You just admitted that you were DIY. You probably...

    You just admitted that you were DIY. You probably screwed something up, which happens sometimes. You dug your own drawer now you have to sleep in it. You are not going to get much sympathy on this...
  23. Replies
    8
    Views
    426

    Stop. Home inspectors are notoriously bad at...

    Stop. Home inspectors are notoriously bad at pointing out problems with HVAC. My in-laws bought their first house and the previous owners’ dog had urinated on their condenser for 15 years and Mr...
  24. The sight glass is not necessary on most...

    The sight glass is not necessary on most residential systems. But if it is cracked something made it crack. Since they didn’t remove the SG I’m assuming the lineset was not changed, would you be...
  25. Thread: What?

    by Pnasty
    Replies
    36
    Views
    1,196

    If the language barrier frustrates you then don’t...

    If the language barrier frustrates you then don’t respond. What you say makes sense in reality but we are on the internet.
  26. Replies
    47
    Views
    1,401

    To make it simple, I would say you both need...

    To make it simple, I would say you both need documentation. The fitting should have some sort of listing to legitimate. If there is no documentation the Fire guy wins. Still the fire guy needs a...
  27. Replies
    12
    Views
    479

    So what is the problem with the OPs install? Is...

    So what is the problem with the OPs install? Is it low because it was missing the field charge. Did you recover the charge and leak check with nitrogen?
  28. Replies
    70
    Views
    13,388

    Normally when I put leak stop in a system I’m to...

    Normally when I put leak stop in a system I’m to lazy to spend the tome looking. Then again digging up posts from 7 years ago will certainly help out the OP.



    Normal I pretend those are the...
  29. Replies
    14
    Views
    392

    If that’s the case, insist on having OEM...

    If that’s the case, insist on having OEM installed. That’s my new advice
  30. Replies
    14
    Views
    392

    Some people stock generic parts on their trucks. ...

    Some people stock generic parts on their trucks. Some techs are under educated. Some techs are lazy. Some techs are in it for a quick buck. Anyone of these can describe your tech. 5 years ago I...
  31. Replies
    2
    Views
    184

    Stop. You don’t know what you are doing. Call a...

    Stop. You don’t know what you are doing. Call a professional. You are not going to receive help on this forum.

    This work is not a hobby, stop treating my trade as if it was. This is how I and...
  32. Thread: 410A CYLINDERS

    by Pnasty
    Replies
    53
    Views
    1,650

    It doesn’t bother me. I’ve been checking the...

    It doesn’t bother me. I’ve been checking the label on the tank anyways, despite the color. I had a tank of 22 and 134a thank turned stainless steel color from not being used Fast enough. Also last...
  33. Replies
    3
    Views
    178

    Based on that very vague info it seems to be...

    Based on that very vague info it seems to be undersized. You’ll save money in the long run by having a properly sized system and duct work installed. My guess is the house was built without AC. The...
  34. What’s your required superheat and sub cooling. ...

    What’s your required superheat and sub cooling. If a coils not clean it’s dirty.
  35. There could be any sort of reason the flow is...

    There could be any sort of reason the flow is different. There could be a restriction a that’s bumped out of the way with reverse flow but restricts again when normal flow is resumed. As has been...
  36. Replies
    9
    Views
    980

    I’m very impressed if that was installed with the...

    I’m very impressed if that was installed with the unit there already.
  37. Replies
    8
    Views
    248

    Not if the blower is running and there is no...

    Not if the blower is running and there is no trap, it will most certainly get stuck in the pan.
  38. That’s a nice $90 switch

    That’s a nice $90 switch
  39. Replies
    12
    Views
    332

    To add 1” wall thickness. I would personally put...

    To add 1” wall thickness. I would personally put the filter drier at the evaporator as well. That way you drop the risk it plugging up and freezing the entire liquid line.
  40. And this is why proper piping techniques are...

    And this is why proper piping techniques are important. It doesn’t matter the material, proper preparation is key for the joint and for the system attached to the piping.
  41. Are you replacing the unit yourself? How do you...

    Are you replacing the unit yourself? How do you know you need a 2.5 ton? There are calculations that tell you how big of a system and then there’s calculations to figure out how much supply air each...
  42. Replies
    27
    Views
    1,015

    This always catches my eye when the HF ads come...

    This always catches my eye when the HF ads come around. i dont do any SM work. But I had to make a evaporator shroud for a reach in cooler and did pretty damn good for only using a 12” bar fold. ...
  43. Replies
    3
    Views
    251

    Time for a phone call or online request for...

    Time for a phone call or online request for service. I would not want you to fry that new thermostat or worse.
  44. Replies
    5
    Views
    342

    My wife won’t even notice. It’s all a selfish...

    My wife won’t even notice. It’s all a selfish fulfillment on my part. I cannot wait for my little one to get older and have him follow me around he’s already obsessed with my work van.
  45. Replies
    5
    Views
    342

    Yes it did, nestled in the tool box drawer with...

    Yes it did, nestled in the tool box drawer with all the other drivers. Thanks for asking.
  46. Replies
    5
    Views
    342

    I felt very accomplished

    I found a misplaced flat head screw driver in my nightstand. I went to bring it to it’s home and instead spent 90 minutes going around the house looking for the little annoying things that never get...
  47. Replies
    6
    Views
    407

    Depending on where you are located if you are...

    Depending on where you are located if you are servicing rental properties you need to be licensed, your state and municipality will have that info. Get your 608 EPA certification. Find a local trade...
  48. Replies
    11
    Views
    2,211

    Is that drive pulley even doing anything besides...

    Is that drive pulley even doing anything besides keeping the belt riding non the shaft?
  49. Replies
    13
    Views
    422

    It’s for when the pool satisfies finally in...

    It’s for when the pool satisfies finally in November and the house hasn’t reached it walk in cooler temp of 37°.
  50. Thread: Blocking vents

    by Pnasty
    Replies
    10
    Views
    372

    Hopefully you are talking about the fan motor in...

    Hopefully you are talking about the fan motor in the condensing unit out side is going to be replaced. At 12 years old I would NOT replace a compressor, the thing that pumps the refrigerant.
Results 1 to 50 of 823
Page 1 of 17 1 2 3 4
Contracting Business