    Nothing but heat pumps in Canada really?? I'd...

    Nothing but heat pumps in Canada really?? I'd worry more about the company doing the install more than the brand Lennox is good but getting parts can be a pain in RI anyway.
  2. If your right on the water get the Coastal...

    If your right on the water get the Coastal coating. The salt air just kills the outdoor units. I've seen it a lot here in the Ocean State. The coating will protect the unit and well worth the extra....
  3. Replies
    8
    Views
    315

    Sounds normal the guy doesnt know what hes...

    Sounds normal the guy doesnt know what hes talking about. Theres a lot of factors that determines the current draw. Refrigerant charge, condenser cleanliness, ambient temp on and on. Ne er e er heard...
  4. Replies
    3
    Views
    251

    Sounds like you may have bought a conventional...

    Sounds like you may have bought a conventional heating cooling thermostat you may have the additional wires because you have a heat pump do you know if you have a heat pump? If you do you'll have to...
  5. Good move calling the gas co. if you were...

    Good move calling the gas co. if you were concerned. Safety never takes a day off. Get them back there but I agree its probably just mineral oil from the manufacturer and they didnt let it run long...
  6. NP. That's a strange little unit. Good luck

    NP. That's a strange little unit. Good luck
  7. The find out the output rating just multiply the...

    The find out the output rating just multiply the input rating by the AFUE efficiency rating. Ex 100,000/in x .80= 80000 output. 100000 .90 = 90000 So if your upgrading to a 90% and you have an...
  8. Its definitely a hot gas bypass. AEVs are for...

    Its definitely a hot gas bypass. AEVs are for constant load equipment like water fountains, and still get fed by the liquid line. Part # for the HGBV is 52-6027-00. Used typically for low load...
  9. Looks like a hotgas bypass valve not a txv. There...

    Looks like a hotgas bypass valve not a txv. There piped and fed from a discharge tee to the inlet of the HGBV the outlet side of HGBV is fed into the evaporator coil. I'll be honest I've never seen...
  10. Dont put the bi-directional drier in backwards....

    Dont put the bi-directional drier in backwards. That would be hard to do now wouldn't it
  11. Replies
    28
    Views
    9,428

    Makes sense, I'll look at the dates from now on.....

    Makes sense, I'll look at the dates from now on.. Thanks for the tip
  12. What's he using round pipe or flex duct for the...

    What's he using round pipe or flex duct for the long runs. I feel for ya I did the same job air flow sucks on the ducted mini splits. Make sure the return duct is properly sized. You would have to...
  13. Replies
    18
    Views
    2,267

    Funny thing is itll probably run fine for years.

    Funny thing is itll probably run fine for years.
  14. Replies
    20
    Views
    2,970

    Oxygen acetylene rig you'll have no problems,...

    Oxygen acetylene rig you'll have no problems, that'll get that bad boy plenty hot.
  15. Replies
    28
    Views
    9,428

    New to the site. Why the hell is a post from 2011...

    New to the site. Why the hell is a post from 2011 still on here. I thought this was just happening. Sorry for the late post. Lol
  16. Oh God. Let's see just reset an oil safety...

    Oh God. Let's see just reset an oil safety compressor blew a head gasket dumping all refrigerant in a cloud of refrigerant and oil. The alarms all went off, fire dept to evacuate 18 story building...
  17. Replies
    182
    Views
    31,567

    Fiberglass duct board sucks use real ductwork.

    Fiberglass duct board sucks use real ductwork.
  18. Replies
    2
    Views
    475

    What was the original compressor doing? If it's...

    What was the original compressor doing? If it's not shorted, or an open winding or grounded. Was it overheating? Why was it changed. Just because of high resistance in the run winding. The varnish...
  19. 35' of 7" duct? That's the only ductwork? 7"...

    35' of 7" duct? That's the only ductwork? 7" round duct is good for 140cfm. I'd installed a small plenum usually you can get them from manufacturer. You can put around 4-5 6" ducts that's about...
  20. Replies
    18
    Views
    2,267

    Lol. Why didn't he mount the condensing unit on...

    Lol. Why didn't he mount the condensing unit on top of the ahu, to make it a package rooftop!! Nice job. Wow
  21. Replies
    28
    Views
    9,428

    I have worked on large air dryers for GE and Fram...

    I have worked on large air dryers for GE and Fram years ago. Have you checked to make sure the HG is feeding during low load conditions, have you adjusted it? What type of compressors are they semi...
  22. Replies
    28
    Views
    9,428

    I have worked on large air dryers for GE and Fram...

    I have worked on large air dryers for GE and Fram years ago. Have you checked to make sure the HG is feeding during low load conditions, have you adjusted it? What type of compressors are they semi...
  23. Replies
    34
    Views
    1,574

    Lol

    Lol
  24. Replies
    3
    Views
    325

    Not sure of license procedures in Idaho. You'd...

    Not sure of license procedures in Idaho. You'd have to be a licensed apprentice for 4 years in Rhode Island before you can get a Journeyman license. But yes get your license or certificate without...
  25. Replies
    4
    Views
    317

    Thats an AMANA furnace Goodman. Try to Google...

    Thats an AMANA furnace Goodman. Try to Google Amama GUI140D50A. Not sure if you'll get a manual thou. Good Luck
  26. Replies
    4
    Views
    317

    [QUOTE=CNSTech;25865009]Can anyone help with...

    [QUOTE=CNSTech;25865009]Can anyone help with locating a Goodman GUI140D50A spec/manual source?
    Many
  27. Replies
    3
    Views
    325

    I started at 16 also. I'm 58 now. So 42 years...

    I started at 16 also. I'm 58 now. So 42 years had my own business with 14 trucks. I would start by getting a position where you'll be exposed to commercial and industrial applications.