  1. Replies
    13
    Views
    812

    there are fan coil unit thermostats that will do...

    there are fan coil unit thermostats that will do the trick.
    http://www.viconics.com/DATA/TEXTEDOC/028-0183-R3-LIT-VT7300-PIR-E03.pdf
  2. cmnet_alert_text.properties # To use this...

    cmnet_alert_text.properties


    # To use this file, assign the alert_auto event template to one or more alarms and specify
    # those alarm's IDs and the alarm text you want to use in the following...
  3. Thread: Carrier Doas

    by PAB
    Replies
    6
    Views
    561

    if its just a Carrier then no. If you happen to...

    if its just a Carrier then no.
    If you happen to have run across the chop-shop Carrier/iAire unit... yes... I don't have a lot to good to say about the second one at the moment... :censored:
  4. Replies
    8
    Views
    410

    If you modstat other modules on the same network,...

    If you modstat other modules on the same network, do they show arcnet errors?
    I am wondering if the terminal unit's power/transformer is right on the threshold of "brownout" voltage.
  5. Replies
    8
    Views
    410

    upper right menu button / drop down menu > manual...

    upper right menu button / drop down menu > manual command (or press Ctrl+M within the WebCTRL interface) > type "download m " without using the ".
    after the module has finished downloading and is...
  6. Replies
    4
    Views
    361

    If it is a reliatel unit, use a relay to bridge...

    If it is a reliatel unit, use a relay to bridge terminals 7 (24v+) and 12 (Hum) on "LTB"
    OR
    land a 4-20ma sensor/plc output on the RH- and RH+ terminals on "NLTB".


    whatever you do... don't...
  7. You have to use "port 2a" to connect ms/tp, as...

    You have to use "port 2a" to connect ms/tp, as the primary port does not have dip switches to bring it down from arc156.
    Verify the following :
    1. you are using port2a,
    2. that the EIA-485/232...
  8. Carrier released the following shortly after the...

    Carrier released the following shortly after the RTU-OPN debuted

    "BACnet Writes to System Points: When an i-Vu Open controller or a 3rd party system writes to any of
    the system points, BACnet...
  9. Thread: Need ALC Help!

    by PAB
    Replies
    19
    Views
    1,140

    out of curiosity what was your final formatting...

    out of curiosity what was your final formatting for the output?
    oh and thanks max... :whistle:
  10. Thread: Need ALC Help!

    by PAB
    Replies
    19
    Views
    1,140

    Well now I'm curious to see if this will work as...

    Well now I'm curious to see if this will work as I haven't tried this from 3rd party devices.
    try to write to
    Binary damper lock flag : bacnet://address/768:1/4141(6) "on/off"
    analog...
  11. Thread: Need ALC Help!

    by PAB
    Replies
    19
    Views
    1,140

    the bacnet property ID is listed in the ALC...

    the bacnet property ID is listed in the ALC literature if you know where to look. If you have access to the ALC front end/server you may be able to look it up.
    The damper is easily doable, but if i...
  12. Replies
    22
    Views
    1,298

    If you could get a vendor key or permission key...

    If you could get a vendor key or permission key from Leibert, you might be able to pull the programs out of the OEM LGR, and load them straight into WebCTRL...
  13. Thread: Dankin VRF

    by PAB
    Replies
    6
    Views
    528

    *69/74 should have read 71/74

    *69/74 should have read 71/74
  14. Thread: Dankin VRF

    by PAB
    Replies
    6
    Views
    528

    I just did a large integration with this system,...

    I just did a large integration with this system, and I believe I may be able to assist.
    There are several settings within the iTM I believe you should verify, as well as insuring you understand...
  15. Replies
    4
    Views
    440

    I'd love to read the rundown on different ways to...

    I'd love to read the rundown on different ways to address the legacy to bacnet translation points. I've had to do it with vav requests to a unit replacement that was delivered as a bacnet unit, and...
  16. Replies
    1
    Views
    460

    You could always set the initiate and terminate...

    You could always set the initiate and terminate temperatures to something really low if the unit seems to be ignoring the disable MWA/DWU settings. I believe the lowest are 50/53.
  17. Replies
    13
    Views
    1,696

    100%. In fact I did another one some time later...

    100%. In fact I did another one some time later in another region, and jokingly asked the carrier startup rep (different group this time) if he had his spare vav installed... he pulled it out of his...
  18. Replies
    13
    Views
    1,696

    I forgot to add, the reason I stated all the...

    I forgot to add, the reason I stated all the above is that 72 is suspicious on all carrier/alc devices as it is the default value for zs sensors when not connected, and could also be the median...
  19. Replies
    13
    Views
    1,696

    Are you sure this is the RTU OPN and not the VAV...

    Are you sure this is the RTU OPN and not the VAV RTU OPN? The VAV RTU OPN has to have a carrier vav controller connected to the comm bus under the vav rtu opn controller so that the unit can...
  20. Replies
    3
    Views
    2,413

    To lock the sensor buttons Simultaneously press...

    To lock the sensor buttons
    Simultaneously press and hold the 2 buttons (override and i ) for 5 seconds to lock the sensor's buttons.
    The display shows a lock icon to indicate the locked state....
  21. Thread: NO WORDS....

    by PAB
    Replies
    26
    Views
    6,771

    is that secondary drain tied into the open frame?

    is that secondary drain tied into the open frame?
  22. I was having a similar issue with a Samsung/Trane...

    I was having a similar issue with a Samsung/Trane bacnet gateway over IP into a secondary LGR. I enabled bacnet firewall on the main LGR and the thing stopped its lock/crash cycle. Although after I...
  23. Sureeeee blame the tab man. I can't tell you...

    Sureeeee blame the tab man.
    I can't tell you how many units I have encountered on which "startup has been completed" (paperwork and all); Yet upon arrival find evidence that there were zero startup...
  24. Replies
    83
    Views
    81,861

    Sticky: Poll: Test and Balance in GA

    Test and Balance in GA