  1. Thread: McQuay WMC 400

    by toptech
    Replies
    2
    Views
    492

    Just found out it flooded and Everything got...

    Just found out it flooded and
    Everything got wet, I'm assuming
    Water ingress is the culprit.
    PC?? Hmm, I think more old think pad has a VGA connection. I'll try that tomorrow..
  2. Thread: McQuay WMC 400

    by toptech
    Replies
    2
    Views
    492

    McQuay WMC 400

    The Super VGA screen is black.
    Dim yellow light is on.
    Powered down chiller and back on.
    Screen is still dark.
    Any guidance would be appreciated.
  3. Thread: CVHE Dry Run

    by toptech
    Replies
    21
    Views
    6,776

    Beuller?

    Beuller?
  4. Replies
    5
    Views
    1,738

    the M.U.A. is not delivering enough C.F.M. for...

    the M.U.A. is not delivering enough C.F.M. for your common areas.
    Have a reputable HVAC company access why.
    Good Luck
  5. Thread: CVHE Dry Run

    by toptech
    Replies
    21
    Views
    6,776

    So, the CH530 will ignore pressure and temp...

    So, the CH530 will ignore pressure and temp signal at start up?
  6. Replies
    13
    Views
    3,915

    iVE GOT A BALANCER SCHEDULED TO COME OUT FOR A...

    iVE GOT A BALANCER SCHEDULED TO COME OUT FOR A TEST AIR RUN.
    During the teardown re assembly I shifted the rear motor bearing bracket to correct spacing at diffuser walls. In addition, the impeller...
  7. turns out it does both If you choose 1 wire...

    turns out it does both
    If you choose 1 wire humidifier during setup, Rc will power ACC- and when humidty is below setpoint ACC- close to ACC+ to output 24VAC
  8. ok, so I found out that ACC+ and ACC- are DRY...

    ok, so I found out that ACC+ and ACC- are DRY contacts on the Ecobee smart stat.
    Problem solved
  9. Ecobee smart thermostat(lastest version) humidifier question

    So i put a new fancy furnace in my house.(Rheem variable speed ,2 stage)
    now i installed a fancy thermostat and i cant get my humidifier to work.
    The Ecobee has 2 terminals ACC + and ACC-
    When I...
  10. Replies
    41
    Views
    3,666

    So everything I've read requires your exhaust air...

    So everything I've read requires your exhaust air to be vented directly outdoors with no chance of it getting recirculated back into your salon.
    for example, does your current multi port fan exhaust...
  11. Replies
    41
    Views
    3,666

    just re read your post, i see you listed your...

    just re read your post, i see you listed your stations
    im doing a little research to see if i can put you in a better mood.
    I hate it when inspectors gum up the works with no knowledge or...
  12. Replies
    41
    Views
    3,666

    i dont agree, from your posts here I think your...

    i dont agree, from your posts here I think your plan and execution of opening your own nail salon has been spot on. You seem very reasonable and on point. I agree with Poodle Head that your inspector...
  13. Replies
    0
    Views
    1,008

    Chicago Loop Chiller Mechanic

    Looking for a Quality Air cooled chiller mechanic.
    Must(not a plus!) Be willing to see the entire picture, every things that effect's chiller operation. Weather it's poor water flow, poor B.A.S....
  14. Replies
    1
    Views
    785

    Subject beat to death? York YCAS

    I guess this might be a little different.
    Every one knows about the loading and unloading issues with the DXS 24,45 compressors
    has Anyone had succes curing the loaded start issue by installing the...
  15. Replies
    1,048
    Views
    67,834

    I think vac gauges are like religion and politics...

    I think vac gauges are like religion and politics sometimes.
    All I can is I keep it clean with isopropyl and it hasn't let me down. I actually have 2 of these. I'm open to a better verified mouse...
  16. Replies
    1,048
    Views
    67,834

    For the record , I was testing my rig only for...

    For the record , I was testing my rig only for that particular photo.
    Look close at the photo for the actual evac location8006111
  17. Replies
    1,048
    Views
    67,834

    Man, I bet your a blast at parties! My hose set...

    Man, I bet your a blast at parties!
    My hose set up is gorgeous! The vac location is fine when you valve it off for a rise test.
    It's not like I said your ghetto vinyl hoses loooked like you...
  18. Replies
    1,048
    Views
    67,834

    800609

    800609
  19. Replies
    8
    Views
    3,059

    i cant believe i just hijacked a thread!...

    i cant believe i just hijacked a thread! apologies, alcohol was involved...
  20. Replies
    8
    Views
    3,059

    so CH17 depicts an external flow switch. thats...

    so CH17 depicts an external flow switch. thats all i got
  21. Replies
    8
    Views
    3,059

    of course the unit diagrams are gone

    of course the unit diagrams are gone
  22. Replies
    8
    Views
    3,059

    i cant find the thermal dispersion flow sensor...

    i cant find the thermal dispersion flow sensor wiring in the wiring manual.
    im pretty sure its only on the unit diagram. can anyone provide the wiring diagram that depicts the switch?
    i have the...
  23. Replies
    11
    Views
    1,349

    some pics AC

    some pics AC
  24. Replies
    11
    Views
    1,349

    it a cover for the compressor contactor and the...

    it a cover for the compressor contactor and the SPM module
  25. Replies
    11
    Views
    1,349

    they staposedly(GTS) put them in to prevent...

    they staposedly(GTS) put them in to prevent extended periods of reverse rotation at shutdown and some other reason that escapes me. Most scrolls have an internal. These Danfoss did not back 2007 ....
  26. Replies
    2
    Views
    738

    To all network service tool users

    I installed a new aquasnap chiller a few weeks ago.
    Version 8 software
    upon commissioning, i disabled all compressors to bring online 1 at a time.
    unit was stuck in control mode 4 emergency....
  27. Replies
    4
    Views
    1,083

    interesting give us an update when ya sort it out

    interesting
    give us an update when ya sort it out
  28. Replies
    11
    Views
    1,349

    ive attached a photo. look at the discharge line...

    ive attached a photo. look at the discharge line on the compressor on far right.
    whats a cct scroll? i dont get out much
  29. Thread: Rtaa retrofit

    by toptech
    Replies
    40
    Views
    13,082

    Ive got a RTAA 070 that is slated for me to retro...

    Ive got a RTAA 070 that is slated for me to retro this year. I will be using 407c, new oil, driers etc.
    i'll then spend a day for testing operation and tweaking the superheat setpoint to match up...
  30. Replies
    11
    Views
    1,349

    Carrier AQUASNAP

    model 30RBA 1005 0 3
    serial 1207Q83256

    Callled out for motor temp fault on circuit A
    Found Danfoss A1 siezed up, explains the motor temp fault.
    I noticed both A1 and A2 compressors have been...
  31. Replies
    18
    Views
    2,145

    Ya know, more than 25 years in this field and...

    Ya know, more than 25 years in this field and Trane can make you feel like a first year rookie when ever it feels like!
    So much logic packed into these units, It can really get overwhelming at...
  32. Replies
    18
    Views
    2,145

    Multiple issues solved 1st Supply fan fail alarm...

    Multiple issues solved
    1st Supply fan fail alarm
    This alarm was caused when the unit shut down and tried to restart the following morning.
    Upon start up, the drive was following a minimum speed...
  33. Replies
    18
    Views
    2,145

    Thanks for replies. I'm heading back there late...

    Thanks for replies. I'm heading back there late morning today.
    The transducer is looking for .25VDC to prove flow I believe in addition to the +.15 the fan proving switch requires to close. Ramp...
  34. Replies
    18
    Views
    2,145

    Suffering a beat down via reliatel

    Model TED600B
    2012
    Varitrac with digital CCP
    Supply fan fail alarm
    Pressure sensor fail alarm
    Unit operates normal for a few weeks and will then throw one or both of these codes.
    Replaced so...
  35. Replies
    21
    Views
    10,305

    Saw this today on a 70 ton RTAA. circuit 2...

    Saw this today on a 70 ton RTAA.
    circuit 2 started up, 50F loop temp, R22. suction pressure went as high as 122 psi. oil temp at 188F. i thought it was the cotton blanket on the inner V coils....
  36. Replies
    14
    Views
    11,727

    Just had a 3 yrs old CGAM130 loose circuit 2...

    Just had a 3 yrs old CGAM130 loose circuit 2 compressors A and B. Any service bulletins on this model?
    2012 install and serial
  37. Replies
    34
    Views
    12,142

    Worst auto correct ever

    Worst auto correct ever
  38. Replies
    34
    Views
    12,142

    Gotta say, I'm sold on the danfoss FC HVAC drive....

    Gotta say, I'm sold on the danfoss FC HVAC drive. The most user user friendly keypad in the history of keypads.
    Plus factory start up gets your customet a 6yr parts andabortion warranty.
  39. Replies
    4
    Views
    1,324

    "Trailing edge" meaning if I remove the steel...

    "Trailing edge" meaning if I remove the steel volute ring on each side of housing there will be hole in the lower end of each blade?
  40. Replies
    4
    Views
    1,324

    Mother of pearl now what!

    It's been a week already:/
    I have a Mcquay air handler
    RDS 806BY
    3MK 00099 03
    Bearing failed on backward incline fan
    While changing the bearing I noticed the wheel balance is off. As I rotate...
  41. Replies
    2
    Views
    1,822

    TESTO 550 BT ICEBERG!

    604471

    This happened while charging an AEC
    Screw chiller.
    2 months old
  42. Replies
    23
    Views
    4,237

    i cut and pasted this from who seems like a smart...

    i cut and pasted this from who seems like a smart guy

    Guys, here's the issue from a VFD mfr's perspective.

    When you UL list a VFD, you are allowed to list it for TWO motor power ratings, based...
  43. Replies
    23
    Views
    4,237

    It always helps to RTFM TAG States rating @ 50C ...

    It always helps to RTFM
    TAG States rating @ 50C = 52.4amps
    Rating @ 40C = 74 amps
    Since this drive is installed in the return airstream it will work just fine.
    Thanks to all
  44. Replies
    23
    Views
    4,237

    Ya it does, i attached a pic of the Tag. im not...

    Ya it does, i attached a pic of the Tag.
    im not sure of this TR1 6027 you mentioned.
  45. Replies
    23
    Views
    4,237

    Man, i could see if i was installing a FORD, but...

    Man, i could see if i was installing a FORD, but this is a Cadillac unit. I just found out a tech came out to repair burnt wires at the motor about a month ago... i put an email into trane expressing...
  46. Replies
    23
    Views
    4,237

    14th digit specs the motor at 30HP in the IOM...

    14th digit specs the motor at 30HP in the IOM
    doesn't spec drive size, 17th digit specs VAV discharge temp control w/ VFD and Bypass
  47. Replies
    23
    Views
    4,237

    SFHLF75FPL00C8AD7D01ADC00000000RT0M8000

    SFHLF75FPL00C8AD7D01ADC00000000RT0M8000
  48. Replies
    23
    Views
    4,237

    Tr-150p18kt2e20h2

    Tr-150p18kt2e20h2
  49. Replies
    23
    Views
    4,237

    [QUOTE=jayguy;19660711]are you going to need all...

    [QUOTE=jayguy;19660711]are you going to need all 30 hp? maybe you will only need 20 hp and all will be ok.[/QUOTE

    Not sure, ill have to assume the design engineers spec'd the 30 for a reason. I...
  50. Replies
    23
    Views
    4,237

    I'm going with factory mistake. This drive can do...

    I'm going with factory mistake. This drive can do no more that 52 amps