  1. Replies
    17
    Views
    1,018

    Not sure on specifics other than that they where...

    Not sure on specifics other than that they where charcoal filters.
  2. Replies
    18
    Views
    1,485

    835990 So something like this would have been...

    835990

    So something like this would have been better?
  3. Replies
    17
    Views
    1,018

    The only thing that I've seen filter well enough...

    The only thing that I've seen filter well enough to get the smell out is charcoal filters. We were at a large waste water treatment facility doing their lab and office space and their OA units had...
  4. Replies
    8
    Views
    642

    I know you mentioned single-zoned equipment, but...

    I know you mentioned single-zoned equipment, but I am starting to do it more and more with VAV's that serve small side-offices that are rarely used. They will have a min. CFM when occupied and will...
  5. I would tell him that the connection point is not...

    I would tell him that the connection point is not even rated for 600 volts. I would tell him that it is on the mfg. for not having the comm. connection it the 'right place'. That's just plain silly.
  6. Thread: Schneider

    by xarralu
    Replies
    23
    Views
    1,754

    Completely agree, somewhere you have to draw the...

    Completely agree, somewhere you have to draw the line.
  7. Damn, that thing is slick.

    Damn, that thing is slick.
  8. Replies
    9
    Views
    1,409

    Yes you can, but there is only one specific model...

    Yes you can, but there is only one specific model (FC-20) that can do this. It does not have an IP port so that is the only way to download the program to it.
  9. Replies
    18
    Views
    1,952

    Does the http://www.hvacrcontrol.com/ router...

    Does the http://www.hvacrcontrol.com/ router thing do this? I know it has modbus capabilities and Lin seems to add features within a week if need be.
  10. Replies
    13
    Views
    1,594

    Sounds like it. I am just trying to stay as...

    Sounds like it.

    I am just trying to stay as close to a 'one-to-one' connection as possible without having to have a JACE or some other widget in the middle.

    I was hoping for a BACnet option...
  11. Replies
    13
    Views
    1,594

    Thanks for all of the info guys. The mech tech...

    Thanks for all of the info guys. The mech tech that was out said the LON card was the only thing available, but after talking to him for a few he didn't sound to confident about other options. So it...
  12. Replies
    13
    Views
    1,594

    Thanks for the info Balibe. It is a CVHE chiller...

    Thanks for the info Balibe. It is a CVHE chiller and it doesn't have the UCP2. It has this

    826911
  13. Replies
    13
    Views
    1,594

    Trane Comm 4 to BACnet Gateway

    Does anyone know of a gateway for Trance comm 4 other than a JACE?

    I've searched through here and the only thing I found that was close is what Balibe posted about back in 1/2021 from...
  14. Replies
    20
    Views
    2,278

    Nice find Amigo. Like fcsm, I have looked as well...

    Nice find Amigo. Like fcsm, I have looked as well and didn't find anything. Have you used these or is this something just came across Amigo?
  15. I have it to where if it gets above 90 degrees...

    I have it to where if it gets above 90 degrees right now and the humidity is below 50% RH. I have 5 float sensors going up the side of a 35 gallon plastic barrel that both units drip into. As long as...
  16. Very true if you use city or well water. A little...

    Very true if you use city or well water. A little off topic, but it might possibly apply to the OP and just a story anyways.

    Years ago Poodle Head Mikey was in on a discussion about using water on...
  17. Thread: IoT gauges

    by xarralu
    Replies
    22
    Views
    21,915

    I have wanted to add superheat and subcool...

    I have wanted to add superheat and subcool readings for my units at the house. I already monitor compressor amps, fan status, and shut down on over amping. I was going to add transducers to monitor...
  18. It is probably the service is starting before the...

    It is probably the service is starting before the IP connection has settled down. Change the service to delayed start and that'll probably fix it.

    824989
  19. Thread: Visio Stencils

    by xarralu
    Replies
    5
    Views
    2,975

    This is a link Orion242 put up years ago, still...

    This is a link Orion242 put up years ago, still works.

    https://www.dropbox.com/s/56v1yyw0s85yosr/Visio.zip?dl=0
  20. Replies
    25
    Views
    3,141

    This is my biggest gripe about Easy IO. If you go...

    This is my biggest gripe about Easy IO. If you go to connect to one that you haven't ever connected to, it is a crap shoot if you have the right kits that are needed.
  21. Replies
    226
    Views
    40,854

    Just bought one just now, I'll dive into ASAP.

    Just bought one just now, I'll dive into ASAP.
  22. I think I know where you are coming from. I did...

    I think I know where you are coming from. I did air balance for a long time, and was sick of the construction sites and traveling. If I had heard one more GC tell me not to mess up his ceiling tiles...
  23. I had this happen in a LX6 lighting panel, tech...

    I had this happen in a LX6 lighting panel, tech support case came back with this that worked for me:

    The values used will depend on how many equipment files assigned to the controller but for a...
  24. Replies
    59
    Views
    7,617

    Can you enlighten us on this as far as where you...

    Can you enlighten us on this as far as where you say the consumer market? Where are you getting this from? So you're telling me every vav will have its own webserver we have to log into just to check...
  25. Replies
    20
    Views
    2,701

    Just to throw this out there, you can lock...

    Just to throw this out there, you can lock outputs in software on these modules and they will stay put during a program download-great for critical applications.
  26. Replies
    10
    Views
    1,327

    I just got back and look what kind of $h!t show...

    I just got back and look what kind of $h!t show this is. They had a meeting after we had talked last and it has come to this. So now it has 904,908, & 922 (the 908 and 922 temporarily with the Easy...
  27. Replies
    10
    Views
    1,327

    It is on the load side-per the cut sheet. Fail as...

    It is on the load side-per the cut sheet. Fail as in the status goes off/open on all three when the drive is steadily pulling 35 amps. Tomorrow, I will be putting them on the line side per the onsite...
  28. Replies
    10
    Views
    1,327

    I am beating this horse right now. Even with 3 in...

    I am beating this horse right now. Even with 3 in parallel it will still fail within a week.

    819012819013
  29. Replies
    27
    Views
    9,600

    Nice sheet metal work. One question, is that the...

    Nice sheet metal work. One question, is that the dryer vent blowing on the CU?
  30. Replies
    54
    Views
    5,517

    Installers, service, and everyone else involved...

    Installers, service, and everyone else involved are going to have to be more network savvy. I just don't see the enticement of it all.

    So, if you have an all IP based system you won't need a...
  31. Replies
    54
    Views
    5,517

    Just to update on ALC's IP unitary controllers....

    Just to update on ALC's IP unitary controllers. Realistically, we will probably see them in less than a years time.
  32. Thread: WebCRTL

    by xarralu
    Replies
    26
    Views
    1,760

    He would see the trends that are still in the...

    He would see the trends that are still in the module (like what he has in the screen shots), he just wouldn't get the historical trends. Also, he won't get alarms either.
  33. Thread: WebCRTL

    by xarralu
    Replies
    26
    Views
    1,760

    It is either that module is losing...

    It is either that module is losing power/communication or you don't have port UDP 47808 open at the server.
  34. Replies
    4
    Views
    2,297

    Try setting your IP network number to 0.

    Try setting your IP network number to 0.
  35. Thread: Moms house

    by xarralu
    Replies
    17
    Views
    9,152

    Nice work. I like how the old one says 'Server...

    Nice work. I like how the old one says 'Server Room'
  36. Replies
    19
    Views
    6,402

    Very nice! Nice to see a DP switch across the...

    Very nice! Nice to see a DP switch across the unit, I wish everyone did this.
  37. Thread: VRF systems

    by xarralu
    Replies
    15
    Views
    4,543

    Agreed. When does the cost of expensive repairs...

    Agreed. When does the cost of expensive repairs take away from what is being saved so much so that in the long run, WSHP are just as or are better on the bottom line?
  38. Replies
    22
    Views
    3,833

    I would bring in enough just to pressurize the...

    I would bring in enough just to pressurize the space/building. Along the lines of 71CHOPS is saying about humidity, if it gets high enough for long enough the building management/owners are going to...
  39. Replies
    96
    Views
    8,195

    https://images.app.goo.gl/M3PdDGWFfRmcy9ph6https:/...

    https://images.app.goo.gl/M3PdDGWFfRmcy9ph6https://images.app.goo.gl/M3PdDGWFfRmcy9ph6814999
  40. Replies
    24
    Views
    2,051

    I've been in controls service for over 10 years,...

    I've been in controls service for over 10 years, and I would add you have to be able to interpolate a lot of times what people are trying to convey to you. Also, don't talk down to them for obvious...
  41. Replies
    10
    Views
    877

    If you have all of the available sensors, I like...

    If you have all of the available sensors, I like to do comparative enthalpy. You need OA temp and humidity and indoor temp and humidity. Of course you should still have a low OAT limit lockout.
  42. Thread: NEWS

    by xarralu
    Replies
    27
    Views
    3,818

    Agreed, we don't mess with trying to service...

    Agreed, we don't mess with trying to service other lines.

    I can't really get them to understand we need to be more diversified. I get what they are saying, but I just want a product in our back...
  43. Thread: NEWS

    by xarralu
    Replies
    27
    Views
    3,818

    Exactly!!! I dabble in most things I can get my...

    Exactly!!! I dabble in most things I can get my hands on that is relatively easy to get to see if it worth it or not. I started using Easy IO where our main product can't do what Easy can. Really...
  44. Thread: NEWS

    by xarralu
    Replies
    27
    Views
    3,818

    Son of a... Schneider Electric bought up Can2Go...

    Son of a... Schneider Electric bought up Can2Go several years back, now this. I hope JCI doesn't do what SE did with Can2Go. The price doubled, we had to give our second born to sign up with SE and...
  45. Replies
    6
    Views
    2,939

    Probably, I am really only used to the Easy I/O...

    Probably, I am really only used to the Easy I/O stuff. I would have thought there would have been a 'toggle' for AX.
  46. Replies
    6
    Views
    2,939

    I think this is what I understand you are trying...

    I think this is what I understand you are trying to do. This will just toggle your output from false to true then back to false every time the one shot comes in.812668
  47. Replies
    5
    Views
    1,598

    Look into Easy IO. Just to start out you only...

    Look into Easy IO. Just to start out you only need one controller, and the software is free. It's very similar to Tridium so if you can understand how to program an Easy IO, Tridium will be a little...
  48. I've used Hmail server...

    I've used Hmail server https://www.hmailserver.com/ for shooting emails from the BMS to a radio system that can receive emails. My reason for using this is because this site does not have internet...
  49. Replies
    25
    Views
    3,677

    I get 160 hours off vacation,and 40 hours sick....

    I get 160 hours off vacation,and 40 hours sick. Total 5 weeks PTO, you get that at the 10 year mark.

    Only travel a handful of times a year and I'm on the service side so I maintain new and old,...
  50. Replies
    15
    Views
    2,227

    811713

    811713