  1. Replies
    4
    Views
    151

    I had no issues with Analog, just binary that I...

    I had no issues with Analog, just binary that I remember (can't remember if they had any multi). If you go through a NAE to IP it translates the character set (no help to you and the BBC-SD) if I...
  2. Replies
    4
    Views
    151

    Do you have issues reading analog values? If this...

    Do you have issues reading analog values? If this issue is only with binary and multistate values it is more than likely due to the BBC-SD not being able to interpret the value text as it is a non...
  3. Negative, no experience with those units. Only...

    Negative, no experience with those units. Only Carrier integration I have done on air handling equipment was back over a decade ago, more recently it had been there air cooled chillers with the OEM...
  4. Code should write on status mismatch. That way if...

    Code should write on status mismatch. That way if someone cycles power to the drive or put it in off and back to auto the command will be sent. Writing Constantine will add unwanted traffic to the...
  5. Replies
    44
    Views
    1,577

    Schneider and Distech locally have gone 100٪ IP...

    Schneider and Distech locally have gone 100٪ IP on their unitary controllers locally. The installers are indicating termination time is increased as well as the additional cost of crimpers and test...
  6. Replies
    44
    Views
    1,577

    Would stick with ARCnet or MSTP@76.8+ for...

    Would stick with ARCnet or MSTP@76.8+ for terminal equipment.

    kontrol out
  7. Replies
    3
    Views
    222

    Per the standard device must support 9600 and...

    Per the standard device must support 9600 and 38400. I prefer 76900 but it's not supported either. :gah:

    kontrol out
  8. Replies
    9
    Views
    538

    I installed approx 100 Schnieder/Andover heatpump...

    I installed approx 100 Schnieder/Andover heatpump split systems and rooftop units. Requires 4 wireless routers to pick up all the controllers due to at the time each one only supported 32...
  9. Replies
    9
    Views
    538

    If your running power to the new controllers why...

    If your running power to the new controllers why not also run communications? Wireless is cool but adds a level of complexity and potential issues in the future.

    kontrol out
  10. Replies
    8
    Views
    520

    Try contacting KMC support. They sent me the...

    Try contacting KMC support. They sent me the latest firmware and instructions to update when I needed it last year.

    kontrol out
  11. Replies
    18
    Views
    1,201

    ALCs zone sensor network that includes an IEA485...

    ALCs zone sensor network that includes an IEA485 interface. More info can be found in ALC literature.

    kontrol out
  12. Replies
    44
    Views
    3,638

    Just like the web, there'll be a "dark" cloud and...

    Just like the web, there'll be a "dark" cloud and it'll bring a downpour with it.

    kontrol out
  13. From memory it just shows you the account login...

    From memory it just shows you the account login and not the activity. The MACHProWeb interface has a detailed audit log.

    kontrol out
  14. Replies
    19
    Views
    794

    I think your going to be out of luck. You may be...

    I think your going to be out of luck. You may be able to write to the airflow microblock if you know the proprietary BACnet object as well as the property number/name. The Microblock Reference Guide...
  15. Sticky: Good add unonut. That is the same one I use but...

    Good add unonut. That is the same one I use but had totally forgot about it as I had started this thread in regards to MSTP.

    kontrol out
  16. Replies
    22
    Views
    1,228

    Now that's funny. kontrol out

    Now that's funny.

    kontrol out
  17. Replies
    16
    Views
    1,208

    Google Honeywell Grey Manual and download the...

    Google Honeywell Grey Manual and download the pdf.
    The controls manuals sold here are some of the best in the industry: ATP Website.
    If you can find a pdf copy of ASHREA 36P there are good examples...
  18. Replies
    25
    Views
    1,108

    You don't download schedules into BACnet...

    You don't download schedules into BACnet controllers, you configure the schedules that reside in the controller already. Some system allows you to create schedules in other vendors controllers if...
  19. Replies
    25
    Views
    1,108

    BACnet integration is no cost. Most systems come...

    BACnet integration is no cost. Most systems come licensed with 25 non-BACnet third party points for protocol integration. From some literature I have seen online the new routers come with 200 points...
  20. kontrol out

    kontrol out
  21. Replies
    18
    Views
    1,201

    Balancing would be a PITA as you would have to...

    Balancing would be a PITA as you would have to get to the VAV controller above the ceiling. A USB-K would be preferable, when I worked for an ALC dealer we had a loaner (that the TAB signed for) and...
  22. Replies
    18
    Views
    1,201

    You can go directly to the Rnet terminals instead...

    You can go directly to the Rnet terminals instead of the pins that plugs into at the controller. You will need it for connecting to a stat, unless you take it off the wall and go to the Rnet...
  23. Replies
    44
    Views
    3,638

    LOL, outage@uptime. kontrol out

    LOL, outage@uptime.

    kontrol out
  24. My opinion is finish what you start, but if the...

    My opinion is finish what you start, but if the pay in considerably higher and you have a family to take care of, take the controls position. I also believe one should install a system of a while...
  25. Replies
    16
    Views
    1,412

    kontrol out

    kontrol out
  26. Replies
    44
    Views
    3,638

    Some of the NKOTB maintain a smoke and mirrors...

    Some of the NKOTB maintain a smoke and mirrors listing with all their sale-speak, double-talk, mis-direction, mis-information and vague references with no factual backup. But hey it tough being a...
  27. Replies
    44
    Views
    3,638

    Siemens has Insight, but it is that proprietary...

    Siemens has Insight, but it is that proprietary expensive software/system you speak of. I for one can't wait till controls is just a commodity like all the other things that have gone the way of the...
  28. So I did this with another system. Easiest fail...

    So I did this with another system. Easiest fail safe would be a photocell as backup.

    For my application I did the sunset/sunrise programming in the main supervisory/router and had all other...
  29. From the App numbers (2023) the FLN devices...

    From the App numbers (2023) the FLN devices appear to be proprietary. Also the other images appear to indicate the same.

    kontrol out
  30. I'm on that now. Get my salary every week (need...

    I'm on that now. Get my salary every week (need to account for my 40 hours at X% utilization) and anything over 40 is paid overtime (with prior approval).

    kontrol out
  31. Replies
    36
    Views
    2,079

    Does it have it's own wall sensor that can adjust...

    Does it have it's own wall sensor that can adjust the setpoint locally?

    kontrol out
  32. Last three have been Maxpedition. kontrol out

    Last three have been Maxpedition.

    kontrol out
  33. Replies
    7
    Views
    543

    When I worked for a East Bay union shop in the...

    When I worked for a East Bay union shop in the San Francisco area the field control personnel were from the PF union. Three of the senior guys at the time taught at the hall.

    kontrol out
  34. Replies
    7
    Views
    543

    In CA back in the day I was classified as PF for...

    In CA back in the day I was classified as PF for federal work and comm tech for state when installing HVAC controls. A co-worker asked the inspector on a AF base if our conduit required a 1" in 12"...
  35. Replies
    36
    Views
    2,079

    Are the points physical inputs or values? I...

    Are the points physical inputs or values?

    I think YABE is one of the better full featured BACnet freeware on the uberwebz.

    kontrol out
  36. I learnt recently on a USAF project that TAB is...

    I learnt recently on a USAF project that TAB is not covered under DB if they are just doing balance and not fixing anything, was quite shocked as I had been doing DB projects for over a couple of...
  37. Replies
    6
    Views
    572

    Any interest in purchasing controls? Over the...

    Any interest in purchasing controls? Over the years I have quite a collection and need to clear up some room in my garage. Contact info is in my profile. I have Alerton, Delta, ALC, Distech, Andover...
  38. Replies
    11
    Views
    729

    http://www.centaurusprime.com/products.html ...

    http://www.centaurusprime.com/products.html

    Bob is one of the good guys in the industry. Halfway down the page is the Siemens solution and if you want to learn more the detailed user manual is...
  39. Replies
    18
    Views
    994

    To share (charge for) the knowledge. Gotta...

    To share (charge for) the knowledge.

    Gotta admit though, he has made a niche for himself in the Industry.

    kontrol out
  40. Replies
    8
    Views
    894

    Welcome to the world of Siemens, without factory...

    Welcome to the world of Siemens, without factory support you'll be fighting an uphill battle. One of the most tightly guarded systems/knowledge base out there.

    kontrol out
  41. Not sure about a wire sheet, but in line code if...

    Not sure about a wire sheet, but in line code if once button is on and timer is > 0 then timer = 0. To stop it from short cycling I would probably program the off sequence with a long (3 second)...
  42. Replies
    108
    Views
    6,943

    Thank the Lord you hate BACNet and not BACnet, I...

    Thank the Lord you hate BACNet and not BACnet, I was worried for a minute. What do you "love" in the place if BACNet?

    kontrol out
  43. Replies
    6
    Views
    375

    Why wouldn't your service company migrate the DB?...

    Why wouldn't your service company migrate the DB? If they are the local ALC dealer and are doing the rest of the scope I would think the database migration would fall on them as well.

    kontrol out
  44. Replies
    15
    Views
    751

    LOYTEC routers/gateways are available through...

    LOYTEC routers/gateways are available through distribution channels such as Kele and possibly ALPS. From my experience cost effective and easy to deploy.

    kontrol out
  45. Replies
    108
    Views
    6,943

    Yeah the diagnostic/status LEDs on each point are...

    Yeah the diagnostic/status LEDs on each point are pretty slick.

    kontrol out
  46. Replies
    15
    Views
    751

    If your just looking for a LON to BACnet gateway...

    If your just looking for a LON to BACnet gateway why not Loytec? Seems a JACE is a little overkill to use just as a gateway.

    kontrol out
  47. Replies
    108
    Views
    6,943

    Reliable have solid controllers (Innotech MSTP...

    Reliable have solid controllers (Innotech MSTP small controllers were just shown at AHR) and probably the best BACnet support in the industry, but I prefer the Innotech graphical based programs and...
  48. Replies
    108
    Views
    6,943

    ALC's WebCTRL is one of the most robust, complete...

    ALC's WebCTRL is one of the most robust, complete and easily deployable software in the market and hands down in my favorite HVAC DDC software other than integration to other vendors. In my opinion...
  49. Replies
    108
    Views
    6,943

    Take a look at Innotech, feature packed and well...

    Take a look at Innotech, feature packed and well priced. Great US based support as well. Programming much like VisualLogic but with more features. The universal IO and web interface set it apart from...
  50. Replies
    14
    Views
    1,704

    What would cause the comm to go down on a regular...

    What would cause the comm to go down on a regular basis? From your comment the ACM locking up is a symptom of an underlying problem.

    kontrol out