  1. Replies
    9
    Views
    297

    To use flex conduit (like sealtite), you'll need...

    To use flex conduit (like sealtite), you'll need to disconnect the low voltage wiring, thread it thru the conduit and then re-connect it properly. If you don't know how, DON'T DO THIS!!!:eek2:
  2. Replies
    9
    Views
    297

    just slit a vinyl hose/tubing lengthwise, and...

    just slit a vinyl hose/tubing lengthwise, and slide it over small wire and then attach hose to side of flexible conduit with wire ties
  3. Replies
    11
    Views
    1,878

    Can't imagine why anyone would try and use R-407c...

    Can't imagine why anyone would try and use R-407c for new equipment. Use R-410a (tag on unit will give freon type). If you see 407c on new equipment, you better check and see why.:eek2:

    My guess...
  4. Replies
    11
    Views
    1,184

    The 16 SEER Amana single or two stage systems had...

    The 16 SEER Amana single or two stage systems had lifetime COMPLETE unit replacement warranties. IMO if you have a zoned system, you need to use the two stage, if single zone, then single stage is...
  5. I totally agree with James!:grin2:

    I totally agree with James!:grin2:
  6. I'd simply set comp. lockout at a few degrees...

    I'd simply set comp. lockout at a few degrees below freezing temp, run system and then once it fails to keep up the house temp. then raise it a degree or two. Kinda a trial and error method, but...
  7. Replies
    28
    Views
    1,622

    It's usually only a small increase in your cost...

    It's usually only a small increase in your cost to go from an 80% to a 92% since the B flue (for the 80%) is much more expensive than 2 inch PVC needed for the 92%. We NEVER put in 80% gas furnace...
  8. Replies
    3
    Views
    641

    go to www.loadcalc.net, it's simple enough. ...

    go to www.loadcalc.net, it's simple enough. Make sure you add the number of people you are wanting it sized for.
  9. Replies
    28
    Views
    1,622

    Also keep in mind that the amount of money spent...

    Also keep in mind that the amount of money spent by any brand on advertising has absolutely NO correlation with the quality of the equipment they sell. BUT it does correlate with the PRICE of the...
  10. Agree with others, you've got a total electric...

    Agree with others, you've got a total electric heat pump system. I'd recommend finding the firm that put that zone system in, have them send an experienced tech out to explain the system to you and...
  11. Replies
    28
    Views
    1,622

    Most "new construction" HVAC (and I use that...

    Most "new construction" HVAC (and I use that loosely) don't have a clue how to run a manual J, they'll simply tell you "That's the size we always use"....so TRY and at least get an manual J heat...
  12. Replies
    28
    Views
    1,622

    Payne is owned by same company as the Carrier....

    Payne is owned by same company as the Carrier. (ICP), so I can't imagine there are huge differences in quality. What is the efficiency of the Payne equipment he is recommending. The "problem" with...
  13. Replies
    15
    Views
    1,455

    You will need to definitely go with a MUCH lower...

    You will need to definitely go with a MUCH lower restriction filter than a Merv 8 1 inch. If you must have a high "Merv" filter then go with a 5 inch Merv 8 but you'll need to install this type...
  14. Replies
    22
    Views
    3,474

    IF you're using a 1 inch Merv 11...

    IF you're using a 1 inch Merv 11 filter.......there's most of your air flow/limit problem. Try a simple 1 inch media (NOT paper pleated!) filter, spray it with endust if you want better dust...
  15. Replies
    9
    Views
    735

    Starting a system takes far more energy...

    Starting a system takes far more energy (electricity) than simply leaving the system running and your comfort level is much better with longer run times. Usually it's much better to have ONE system...
  16. As others here will tell you, we are FORBIDDEN to...

    As others here will tell you, we are FORBIDDEN to attempt in assisting DIY repairs. You need to call a licensed, insured, professional and make sure you tell them that your system has a "smart"...
  17. Replies
    57
    Views
    5,999

    We don't use any "duct board" as we've seen it...

    We don't use any "duct board" as we've seen it simply fall apart in extreme temperatures and high humidity use. I'm sure the foil tape was probably NOT the correct type, but have seen way too many...
  18. Replies
    8
    Views
    616

    I agree with other posters, you really need...

    I agree with other posters, you really need someone to do an actual load calculation and then go from there. We've NEVER been able to get 4 inch pipes to flow adequately for newer AC units. We...
  19. Replies
    10
    Views
    1,469

    Those kind of pressures may cause a frozen coil,...

    Those kind of pressures may cause a frozen coil, but there are other things that will also cause the low pressure instead of freon level or expansion valve. What all did the tech check? With those...
  20. Replies
    5
    Views
    2,629

    go to www.loadcalc.net and start there.

    go to www.loadcalc.net and start there.
  21. Do you have a humidifier on this system, if so,...

    Do you have a humidifier on this system, if so, what type?
  22. Replies
    2
    Views
    523

    I agree the 5 inch filter will flow better than a...

    I agree the 5 inch filter will flow better than a 1 inch. What size AC does this furnace have on it? What is the full model number? Most Goodman units do not allow a larger opening than 16x25 on...
  23. Replies
    7
    Views
    2,412

    As far as I know, all AHRI rated air conditioners...

    As far as I know, all AHRI rated air conditioners come with a "match" for just the AC and indoor coil regardless of the furnace used. Many times a TXV will be needed to get the rated SEER, but not...
  24. Replies
    12
    Views
    3,399

    I would imagine you are experiencing the effect...

    I would imagine you are experiencing the effect of a multi-stage high efficiency air conditioner. It runs in a lower speed (1st stage) and from time to time uses the high speed (2nd stage), however...
  25. As with any apartment complex using systems like...

    As with any apartment complex using systems like this....you should always have a supply of new/repaired units to quickly replace the one that quit. Whoever is doing your maintenance is aware of...
  26. A 2 1/2 ton unit drawing 26 amps?? Seems too...

    A 2 1/2 ton unit drawing 26 amps?? Seems too high to me...
  27. Replies
    61
    Views
    4,728

    Amana units are more expensive than Goodman units...

    Amana units are more expensive than Goodman units because they have a few more "bells and whistles" and also usually have longer warranties right out of the box. We can't give "legal" advice, but...
  28. Some "zoning" systems use a "first call, first...

    Some "zoning" systems use a "first call, first serve" type demand, so wait and let one zone get satisfied and see if it shifts over to the other zone before you call anyone. Most newer systems will...
  29. Thread: Equipment Pad

    by wahoo
    Replies
    5
    Views
    1,322

    The problem with concrete pads are that they will...

    The problem with concrete pads are that they will also "settle" and then are much more difficult to re-level. Many times (if not always) the concrete pad is far heavier in weight than the unit it...
  30. Replies
    7
    Views
    2,412

    If you use the existing furnace, you will limit...

    If you use the existing furnace, you will limit your actual SEER rating to somewhere around 15 or so. If your existing ductwork is metal, and it's sized properly, then you can usually re-use it. If...
  31. Replies
    26
    Views
    9,361

    Thanks for posting it Bill!! So the earlier tech...

    Thanks for posting it Bill!! So the earlier tech did something "inappropriate"? I guess my "illegal" question got answered? We all try and do the "best standards", but most of us fail at some...
  32. Replies
    26
    Views
    9,361

    Illegal??? Please post the statute that says...

    Illegal??? Please post the statute that says that....please. I'm from the "show me" state!
  33. Replies
    19
    Views
    1,082

    You better check on warranty for any equipment...

    You better check on warranty for any equipment purchased online. Most demand that it be installed by a licensed and certified installer in order to have any warranty....check it out first! Some...
  34. Replies
    26
    Views
    9,361

    Thanks Bill!:grin2:

    Thanks Bill!:grin2:
  35. Replies
    19
    Views
    1,082

    Any professional should be able to size a new AC...

    Any professional should be able to size a new AC unit. Call one please! If I remember correctly Tempstar is an ICP product
  36. Replies
    26
    Views
    9,361

    We try and keep our customers comfortable, maybe...

    We try and keep our customers comfortable, maybe you can do that by whatever "professional" standards you wish......call the freon "situation" what you want, it's still the same situation and NOT of...
  37. Replies
    26
    Views
    9,361

    Go to your local supply shop and ask how much...

    Go to your local supply shop and ask how much R-22 is sold verses the replacement blends.....that'll tell you how common this is. Right? Wrong? or otherwise.....mine told me they hardly EVER sell...
  38. Thread: R407 Conversion

    by wahoo
    Replies
    10
    Views
    1,681

    I'd make sure and do the simple stuff...

    I'd make sure and do the simple stuff first...like wash the outside condenser coils out really well, and make sure the indoor filter is new, clean, and NOT A PLEATED (ZIG/ZAG) TYPE FILTER....(pleated...
  39. Replies
    2
    Views
    514

    Agree.....depends. A lot of universal motors can...

    Agree.....depends. A lot of universal motors can be configured to nearly match the OEM unit.
  40. Thread: R407 Conversion

    by wahoo
    Replies
    10
    Views
    1,681

    May have a leak? Has a competent technician...

    May have a leak? Has a competent technician found a leak?:whistle:
  41. Replies
    10
    Views
    1,469

    At this point, who the heck knows? The...

    At this point, who the heck knows? The "diagnostics" are all over the place.......:gah: I agree with others, you really need a competent tech!
  42. Replies
    26
    Views
    9,361

    Pure new R-22 cost may now make you take a 2nd...

    Pure new R-22 cost may now make you take a 2nd mortgage to afford, so LOTS of techs are using other, lower cost freon mixes. It's only going to get more and more common. Yet I'm pretty sure there...
  43. Replies
    7
    Views
    669

    The American Standard unit is probably rated "up...

    The American Standard unit is probably rated "up to" 14.5, but seldom will a normal installation attain that efficiency. Only in certain match ups of indoor equipment. As others have said, the...
  44. Replies
    3
    Views
    1,896

    It's probably the insulated flex pipe, do what...

    It's probably the insulated flex pipe, do what lynn says and it'll go away.
  45. Have another qualified contractor look this job...

    Have another qualified contractor look this job over, there's probably more stuff wrong than just the drain and lack of back up pan. Yes, any time you put a condensing furnace OR AC coil in attic...
  46. Replies
    21
    Views
    1,363

    A lot of variables here. What type of flue do...

    A lot of variables here. What type of flue do you have? If it's a brick flue and you go to the 95% then you'll need to line it for the water heater (if it's gas). the ECM motor on the 80% will run...
  47. Replies
    9
    Views
    6,853

    You would need to find average cooling hours for...

    You would need to find average cooling hours for your area, I'd guess at @500 hours and then determine your cost of electricity. In our area I use $.10 a KWH. Then you can find your average...
  48. Replies
    25
    Views
    1,234

    Leave the fan set to on, and open the door a...

    Leave the fan set to on, and open the door a couple of inches. See what changes. Is it critical that this room stay a certain temp? Okay, just noticed it's the baby's room...sorry. We've used...
  49. I'd stay with a Merv 10 or 11. Any filter with a...

    I'd stay with a Merv 10 or 11. Any filter with a Merv 16 has to have more restriction than the more common Merv10 or 11. More restriction means less air flow, lower efficiencies, and higher...
  50. If both floors are about the same size, then the...

    If both floors are about the same size, then the larger AC should be in the UPPER floor......cold air falls and heat rises!