Search:

Type: Posts; User: jim bergmann

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. We are going to work on it soon. Not sure it will...

    We are going to work on it soon. Not sure it will be as graceful as you may have to switch it between functions to get everything.

    Thanks

    Jim
  2. Replies
    48
    Views
    3,794

    Trending is the most powerful feature of the...

    Trending is the most powerful feature of the gauge. You can see if it is dry and tight (1), wet(2), actively removing liquid moisture(3), or if it has a leak. Other gauges do not have the accuracy, ...
  3. Replies
    10
    Views
    1,185

    The Accutools is made by Accutools. They have...

    The Accutools is made by Accutools. They have actually made a few improvements to it since the initial design. It has a different gasket design, no double o-rings, providing a much better seal, and a...
  4. Replies
    47
    Views
    6,981

    No, Testo did not make them long-range and I do...

    No, Testo did not make them long-range and I do not know if they have plans to or not. For the most part the manometerís donít matter, we built capture buttons into MeasureQuick so you donít have to...
  5. Replies
    5
    Views
    669

    The MQ is not incorrect, the app displays the...

    The MQ is not incorrect, the app displays the weighted midpoint of the evaporator and the midpoint temperature of the condenser. We do this so you can have the average coil temperature. This is...
  6. Replies
    2
    Views
    646

    Not possible from the outside. We can add it to...

    Not possible from the outside. We can add it to MQ if we have the information.

    Jim
  7. The software can be on the iPad, just do not...

    The software can be on the iPad, just do not connect the hearing aids to the iPad when the FP probe are in use
  8. I would venture to say so. You might consider a...

    I would venture to say so. You might consider a separate tablet to run them on as the best solution. I pad mini is my recommendation.
  9. I just did some range testing to dropout and...

    I just did some range testing to dropout and reconnect testing and everything is working well. I am not sure what might be causing any issues.
  10. Replies
    12
    Views
    974

    The Redfish iDVM550 works really well for that...

    The Redfish iDVM550 works really well for that and does a lot more than that. It is priced right too.


    https://youtu.be/szjQakkRjsQ
  11. Are you using a BT headset? A headset or earbuds...

    Are you using a BT headset? A headset or earbuds will cause that type of issue. Could also be local interference. We have not seen any issues.
  12. Replies
    47
    Views
    6,981

    The hardware is good, just very expensive. There...

    The hardware is good, just very expensive. There are a lot of good competitors that are a fraction of the cost that work as well or better for most all applications. With MQ you have a lot of...
  13. Replies
    47
    Views
    6,981

    Doing away with hoses is the way to go. Smart...

    Doing away with hoses is the way to go. Smart probes are a much better option. The Fieldpiece probes are very good as well as the Testo. If you go with the Testo make sure you get the extended range...
  14. What are the features you like on the JL app?

    What are the features you like on the JL app?
  15. Hopefully in the next day or so.

    Hopefully in the next day or so.
  16. I will make a slight adjustment to when the...

    I will make a slight adjustment to when the targets are adjusted, Iíll change it from 60 to 65%. Let me know if that works better for you. I was looking for some feedback. Thanks.
  17. Replies
    18
    Views
    2,017

    The SM480v and 380v both are joe supported. Go to...

    The SM480v and 380v both are joe supported. Go to the toolbox, scan for new tools and Iíll come up under the Fieldpiece probes
  18. The return only effects the head pressure when...

    The return only effects the head pressure when the latent load load is way out of the typical range. Basically the latent load is overloading the coil. Under typical conditions the offset never comes...
  19. Again, what I think you are seeing is the high...

    Again, what I think you are seeing is the high latent load correction. You can overload the coil with latent capacity and drive the suction and head up accordingly. If the RH and DP are really high,...
  20. I am testing it right now and cannot duplicate...

    I am testing it right now and cannot duplicate what you are seeing. On your pressure probes, do you have the ODA sensor plugged into the T2, and the SLT to T1, nothing plugged into the RH probes?...
  21. The Return air target is set by RADB, and the...

    The Return air target is set by RADB, and the head pressure by ODA temp.
  22. I just did a bunch of testing and everything is...

    I just did a bunch of testing and everything is working fine. I used 70 degrees and 85 degrees. That said, we are doing some target adjustments for high WB on the evaporator that will drive the DTD...
  23. Replies
    18
    Views
    2,017

    That was never the intent nor do we advertise it...

    That was never the intent nor do we advertise it that way. It is an indirect measure of airflow and not a volumetric measure. It is far better then what most techs have to measure airflow which is...
  24. Replies
    18
    Views
    2,017

    The estimated airflow is basically a mass flow...

    The estimated airflow is basically a mass flow calculation and is a more accurate way to get airflow in a residential system than an anemometer or even a capture hood in many cases simply because of...
  25. That is on the MQ development roadmap. We have...

    That is on the MQ development roadmap. We have full access to iManifold hardware. It will be done, we are wrapping up some more pressing projects. Good news is we just added to more programmers so in...
  26. Replies
    110
    Views
    18,222

    I figured at some point this would come up. ...

    I figured at some point this would come up.

    There are only a few contract manufacturers of meters in the entire world and they are used because the market for specialty meters is small and the...
  27. Replies
    110
    Views
    18,222

    There is quite a bit on the way still, but...

    There is quite a bit on the way still, but improvement in EER is an important feature, and customers do understand an increase in efficiency. We will be quantifying savings in some of the reporting....
  28. Replies
    110
    Views
    18,222

    Mark, As far as resistance, I am not...

    Mark,

    As far as resistance, I am not surprised. I know you are getting a reading on your other meter, but neither is accurate in that low range. You need one more significant digit to really know...
  29. I would participate. We are getting ready to...

    I would participate. We are getting ready to start some training courses on MQ now that we are wrapping up some of the core feature development. Let me see what we can come up with. This blog is a...
  30. Replies
    11
    Views
    715

    That makes no difference.

    That makes no difference.
  31. Replies
    11
    Views
    715

    If you have watched the video, and know you have...

    If you have watched the video, and know you have it in the right ports, it could be defective. If so, let us know and I will have it swapped out. There is no fuse or anything internally, it is simply...
  32. Replies
    8
    Views
    1,083

    That Testo 416 is still a tool in my tool bag....

    That Testo 416 is still a tool in my tool bag. IMHO the best induct anemometer on the market for ducted residential applications. It takes a little time to fully master, but once done it provides a...
  33. Replies
    61
    Views
    7,583

    The Fieldpiece Joblink probes have been really...

    The Fieldpiece Joblink probes have been really solid. Used with MeasureQuick they are a great combination.

    Jim
  34. Replies
    1,040
    Views
    54,961

    Oil and moisture management go hand in hand. A...

    Oil and moisture management go hand in hand. A small amount of oil gets contaminated quickly. Also, you lose oil from misting. Larger pumps have 2 or more quarts of oil allowing them to run much...
  35. Replies
    1,040
    Views
    54,961

    Yep, that is it.

    Yep, that is it.
  36. Replies
    1,040
    Views
    54,961

    With standard oil, about 7 microns in a minute or...

    With standard oil, about 7 microns in a minute or so. All I had was the FP oil. I am guessing it would do a few microns better with the NAVAC industrial oil.
  37. Replies
    1,040
    Views
    54,961

    We have been testing a few of the NAVAC pumps,...

    We have been testing a few of the NAVAC pumps, with standard oil we can easily get down to the sub-10-micron range and the industrial oil, I can get down between 0-2. It gets so low that we are in...
  38. Replies
    110
    Views
    18,222

    Here is a good explanation. There are times that...

    Here is a good explanation. There are times that accuracy is critical and times when we simply need to know if a voltage is present. There are cost/benefits. The trick is to find a meter that...
  39. Replies
    110
    Views
    18,222

    They already work with MQ. There are about 50...

    They already work with MQ. There are about 50 units in the field in beta testing. So far so good. They were released to the beta testers several months ago.
  40. Replies
    110
    Views
    18,222

    Here are the detailed specifications. I am sure a...

    Here are the detailed specifications. I am sure a magnet will be either on the meter or available as Supco distributes the HVAC Strap magnet. Here is what we have prototyped up. It works very well. ...
  41. Replies
    11
    Views
    1,376

    Thanks, that is the one. I found the same. I...

    Thanks, that is the one. I found the same. I wanted to test our outputs against it to see how they line up.
  42. Replies
    11
    Views
    1,376

    That was helpful for other reasons, thanks. Not...

    That was helpful for other reasons, thanks. Not what I was looking for though.
  43. Replies
    11
    Views
    1,376

    Thanks, that was part of the chart for sure....

    Thanks, that was part of the chart for sure. Hopfully somone reads this and has the rest.
  44. Replies
    11
    Views
    1,376

    Heat pump heating mode chart

    At one time one of you posted a chart for heat pumps in the heating mode that had information on target split based on ODA temperature as well as a slew of other information. It also had some...
  45. Replies
    9
    Views
    1,006

    I belive that is the way it was done for years.

    I belive that is the way it was done for years.
  46. Replies
    9
    Views
    1,006

    https://www.hydraulicsdirect.com/SS-1501-Stainless...

    https://www.hydraulicsdirect.com/SS-1501-Stainless-Steel-Pipe-Swivel-p/ss-1501.htm
    http://www.hydraulicsdirect.com/SS-1404-Stainless-Steel-Pipe-Swivel-p/ss-1404.htm
  47. They go much deeper much faster than any other...

    They go much deeper much faster than any other hoses. Just comparing the hose will show a significant difference. The TruBlu hoses have 1-3 microns of loss when the competitors often over 100.
  48. Replies
    7
    Views
    1,491

    Right now, no one. The meter was introduced at...

    Right now, no one. The meter was introduced at AHR; they should be available in February. We will incorporate it into MQ before the release.
  49. Replies
    110
    Views
    18,222

    Our design in Asia. Our IP is really in the...

    Our design in Asia. Our IP is really in the Bluetooth protocol and in the application. We simply need a meter with the accuracy and resolution for things to work as well as the specifications we ned...
  50. Replies
    110
    Views
    18,222

    I am guessing that they will get an order in...

    I am guessing that they will get an order in early. Supco is the distributor, so they will go to them first.