  1. Replies
    33
    Views
    918

    that is what got this post reported and also...

    that is what got this post reported and also garnered the comment.
  2. Replies
    33
    Views
    918

    You might want to call a service tech to...

    You might want to call a service tech to determine what the malfunction is.
  3. Daikin and Toshiba make their own equipment. Find...

    Daikin and Toshiba make their own equipment. Find out what manufacturer produces the Trane and Rheem units. These like many products have only a limited number of manufacturers compared to infinite...
  4. You are listed as a homeowner. What does your...

    You are listed as a homeowner.
    What does your contractor suggest?
  5. Replies
    29
    Views
    2,510

    Heating, Units Without Economizer 04A--07A...

    Heating, Units Without Economizer 04A--07A (single compressor model): When the thermostat calls for heating, terminal W1 is energized. DFB receives this input at P2Ė7. The DFB removes the output at...
  6. Replies
    9
    Views
    657

    Did NEC change from ALL wiring in conduit MUST...

    Did NEC change from ALL wiring in conduit MUST have same rated insulation? The intent of that is to prevent electrical interference/electric field generation.
  7. Replies
    29
    Views
    2,510

    This is a GEMINI series machine. 1- t-stat HAS...

    This is a GEMINI series machine.
    1- t-stat HAS to be configured as ELECTRIC HEAT.
    2- DO NOT set heat cycle rate above 5, 4 is better. If set higher than 5 cph the control board will see this as a...
  8. He gone.

    He gone.
  9. When the need arises for a service call again;...

    When the need arises for a service call again; when you place that call, ask the perspective organization if their technicians have adequate test instruments. Unless a LOT was left out of your...
  10. Replies
    3
    Views
    347

    ....and what kind of webinar or virtual event is...

    ....and what kind of webinar or virtual event is this???
  11. Replies
    29
    Views
    2,510

    Is this a GEMINI unit?

    Is this a GEMINI unit?
  12. Thread: New here

    by dandyme
    Replies
    7
    Views
    1,702

    I want to know what is the prize since this is in...

    I want to know what is the prize since this is in CONTEST! CONTEST!?
  13. Replies
    23
    Views
    543

    "AC Ready Kit", that's a different name for it....

    "AC Ready Kit", that's a different name for it. Please tell us the tech didn't call it that.
  14. thought they stated #1 is on, oh well.

    thought they stated #1 is on, oh well.
  15. The manual indicates that when switch #! is in ON...

    The manual indicates that when switch #! is in ON position, the unit is in EMERGENCY HEAT, your electric heat is the only heat operating.
  16. Replies
    2
    Views
    644

    Didn't read the rules you agreed to when signing...

    Didn't read the rules you agreed to when signing onto site did you.
    Pricing NOT ALLOWED.
  17. Are you sure that #1 compressor is capable of...

    Are you sure that #1 compressor is capable of operating?
  18. Replies
    22
    Views
    925

    Here daily mostly. Discouraging to see the newer...

    Here daily mostly. Discouraging to see the newer "techs" have no inkling how to troubleshoot, but have no problem coming here and wanting solution to their problem, almost like a homeowner. These...
  19. acetylene above 15# psi will try to come out as a...

    acetylene above 15# psi will try to come out as a liquid, EXPLOSIVE.
    my normal set up: oxy 10-15# unless cutting tip in use, acty: no more than 7#.

    If you are ever really bored, inflate a balloon...
  20. Replies
    50
    Views
    2,625

    Because we don't like you. :spitball::gah::beat:

    Because we don't like you. :spitball::gah::beat:
  21. Thanks for the heads up. #BringBackCoolKwiz

    Thanks for the heads up.
    #BringBackCoolKwiz
  22. Is this unit under warranty??? If yes, call your...

    Is this unit under warranty???
    If yes, call your installer and stop playing with things that may hurt you.
    If no, call a service company if you have "issues" with installing contractor.
  23. Replies
    10
    Views
    1,325

    Poor thing was tired and needed a nap.

    Poor thing was tired and needed a nap.
  24. Replies
    7
    Views
    702

    Same effect. Pressure differential. Never seen...

    Same effect. Pressure differential. Never seen mono flo tee for cast iron.
  25. Replies
    32
    Views
    3,192

    Unless that is the exterior wall? "This...

    Unless that is the exterior wall?
    "This accessory must be used only for terminating the vent of a Category IV furnace. Do not use this termination kit for any other type furnace. Failure to follow...
  26. Replies
    24
    Views
    1,701

    1-why is the pressure "creeping up" once the...

    1-why is the pressure "creeping up" once the solenoids open?
    2-just what kind of time delay between contactors pulling in?
  27. Replies
    6
    Views
    354

    Is the system NOT under warranty?

    Is the system NOT under warranty?
  28. If a job is posted and one wants to know the...

    If a job is posted and one wants to know the answers to those questions; if one was motivated enough they would contact the party posting the job.
    So many times I've notified someone of a job...
  29. 1-Did not see design conditions? 2-Does it get...

    1-Did not see design conditions?
    2-Does it get below freezing?
    2a-Did mfg remove criteria of insulating venting in area subject to freezing temps?
    2b-Is that drain line going to be insulated/heat...
  30. Replies
    10
    Views
    449

    The equipment will have to rated for manufactured...

    The equipment will have to rated for manufactured housing unless your duct work is replaced.
    Coleman is rated, trane was at one time, there are probably others.
  31. Replies
    12
    Views
    1,119

    are those 2 questions your addy? otherwise, did...

    are those 2 questions your addy?
    otherwise, did not see it.
  32. Replies
    12
    Views
    1,119

    you've got mail

    you've got mail
  33. Replies
    28
    Views
    1,922

    WD-40, rags... spray that shaft, wipe the crud...

    WD-40, rags... spray that shaft, wipe the crud off of it.
    60 grit sandpaper.
    WD-40, hammer on everything, might want to have ear plugs at this point.
    repeat any and all steps necessary.
  34. Replies
    3
    Views
    791

    So, you're soliciting to be a qualifier?

    So, you're soliciting to be a qualifier?
  35. Replies
    28
    Views
    1,329

    Well, how is the 3 legged turkey farm out by the...

    Well, how is the 3 legged turkey farm out by the nuclear plant doing?
  36. Replies
    7
    Views
    684

    That air handler number is deceptive in its...

    That air handler number is deceptive in its presentation. the "60" is it's MAX capacity. you have got to get the number off the coil itself to verify coil size.
    That is a but load of moisture on the...
  37. A business owner does not have to licensed, BUTT...

    A business owner does not have to licensed, BUTT the company HAS to have a licensed full time employee in order to be a contractor. The license covers INSTALLATION. A service only HVAC company needs...
  38. Replies
    10
    Views
    602

    It identifies as a heater :eek::toetap::oops:

    It identifies as a heater :eek::toetap::oops:
  39. Replies
    2
    Views
    596

    is the thermostat not wired to power the...

    is the thermostat not wired to power the reversing valve?
  40. Replies
    6
    Views
    647

    That hurt to read. Can only hope your verbal...

    That hurt to read.
    Can only hope your verbal communication is somewhat better than your written.
  41. Replies
    5
    Views
    780

    I was of the understanding that 3rd party...

    I was of the understanding that 3rd party automation networks did not play well with VRV/VRF systems. Or have a I missed the latest info?
  42. Replies
    6
    Views
    497

    Why not ask your neighbor who they recommend?

    Why not ask your neighbor who they recommend?
  43. That looks to be a small rosebud tip. It that...

    That looks to be a small rosebud tip.
    It that payson that was here several years back?
  44. Replies
    18
    Views
    1,208

    Is this a vrf? did you move the little jumper at...

    Is this a vrf?
    did you move the little jumper at the top of pcb board to new board?
    just what was the error code originally?
  45. Replies
    16
    Views
    581

    If you're adding load you better check the duct...

    If you're adding load you better check the duct design.
    You can just rob peter to pay paul.
  46. Replies
    28
    Views
    1,373

    1-are the tech's from the installing contractor?...

    1-are the tech's from the installing contractor?
    2-jumping to different service contractor each service call is doing nothing for you because each time the new tech is starting from ground zero and...
  47. Replies
    13
    Views
    1,036

    Operating Sequence COOLING, UNITS WITHOUT...

    Operating Sequence COOLING, UNITS WITHOUT ECONOMIZER — When thermostat calls for cooling,terminals G andY1areenergized. The indoor-fan contactor (IFC) and compressor contactor are energized and...
  48. Replies
    0
    Views
    629

    Winston-Salem NC

    Hiring residential service techs.
    www.Loganhvac.com
  49. Replies
    7
    Views
    455

    TXV? slow to respond? occasionally shutting...

    TXV?
    slow to respond?
    occasionally shutting down?
  50. Replies
    2
    Views
    330

    " I check all power and all is good, 120v each...

    " I check all power and all is good, 120v each leg both pre and post" enlighten me as to what that means.
    Where are you checking power at & to?
    "pre & post" what?