  1. Replies
    5
    Views
    118

    No, never worked on one. Most serial menus...

    No, never worked on one.

    Most serial menus systems walk you through each step though. Getting connected with baud rate and pins is generally the hard part.
  2. Replies
    5
    Views
    118

    putty is the modern replacement for the dead...

    putty is the modern replacement for the dead product hyperterminal
  3. Replies
    2
    Views
    120

    Try moving your priority up. Some equipment...

    Try moving your priority up. Some equipment already have something linked to those lower priorities and you get ignored with something as high as 12.
  4. Replies
    13
    Views
    252

    I thought you had a portal, small plastic box and...

    I thought you had a portal, small plastic box and looks like a ALC eqportal. You'll need someone that knows more about carrier stuff.

    Also there's HVACRControl that has a CCN gateway that could...
  5. Replies
    13
    Views
    252

    No, address on the secondary side (MS/TP) of the...

    No, address on the secondary side (MS/TP) of the BACnet gateways needs to be unique. The CCN side can stay the same. That's assuming they are working in the first place.
  6. Replies
    13
    Views
    252

    They will each need a unique MAC (rotary switch)...

    They will each need a unique MAC (rotary switch) and device instance. After that you should be good to put it under some router to get it to the gateway.
  7. Replies
    13
    Views
    252

    Are they currently talking to something on MS/TP?...

    Are they currently talking to something on MS/TP? Are the rotary addresses all the same?
  8. Replies
    19
    Views
    657

    In a perfect utopia starting from scratch with...

    In a perfect utopia starting from scratch with present tech this stuff makes some sense. Expecting the construction and BMS industry to change overnight is the part that isn't going to happen. Just...
  9. Replies
    7
    Views
    266

    OK so if simply adding another IP to the NIC...

    OK so if simply adding another IP to the NIC isn't enough because there's other resource conflicts you can always virtualize. Create another machine in something as simple as virtual box, bridge the...
  10. Replies
    7
    Views
    266

    Is this a simple "port 47808 is in use by another...

    Is this a simple "port 47808 is in use by another application" issue? I'm not familiar with that software.

    If it is though you can add another IP address to the NIC and have each app use one IP...
  11. PSA; Cisco SDA and DNA default settings break broadcasts and BACnet discovery

    This was posted to an internal user group but could potentially impact many of us;



    To me it seems like the "L2 flooding" being disabled by default is definitely a contributing factor.
    ...
  12. Replies
    19
    Views
    657

    The BMS industry predates these things and has a...

    The BMS industry predates these things and has a much slower adoption of technologies. The BMS equipment is tied to the life cycles of buildings, not the IT gear inside them.

    Secondly you are...
  13. Replies
    1
    Views
    226

    I'm not sure about the chiller points but I think...

    I'm not sure about the chiller points but I think it just detects the device type and gives you a generic point template of all the possibilities and the points that read work, the ones that don't...
  14. Replies
    8
    Views
    490

    Buckle up, story time. The ALC WebCTRL product is...

    Buckle up, story time. The ALC WebCTRL product is a lot more focused and with that comes some simplicity and elegance as long as you are doing what it is designed for. The tools like eikon and...
  15. Replies
    8
    Views
    490

    Free courses on Tridium University, you...

    Free courses on Tridium University, you registered there yet?

    Introduction to Niagara 4 (FREE)...
  16. Replies
    17
    Views
    775

    I don't think Tridium is the latest buzz word but...

    I don't think Tridium is the latest buzz word but I like all the articles and training material. Thanks.
  17. Replies
    46
    Views
    1,127

    Customer still OK with this? At a certain point...

    Customer still OK with this? At a certain point I'd invoke the sunk cost fallacy and move for a replacement/upgrade.
  18. Was it required to have a third party interface...

    Was it required to have a third party interface for the job?

    That does sound like it's using modbus internally but that doesn't necessarily mean it can put that out to another vendor.
  19. Replies
    4
    Views
    338

    That's interesting, I remember looking into this...

    That's interesting, I remember looking into this last year when I had to get this to an IT person and remember thinking it odd Tridium didn't have a specific MAC vendor. Wonder why they never got...
  20. Replies
    3
    Views
    263

    That's an interesting idea. Being this is a ...

    That's an interesting idea. Being this is a translator box (fieldserver?) I'm kinda thinking it won't do anything though.

    The other replies got lost in the forum rollback. There was speculation...
  21. Replies
    10
    Views
    514

    I used to joke that fdisk was the best utility...

    I used to joke that fdisk was the best utility microsoft ever released, it fixes everything. You use fdisk to wipe out your C:\, reinstall windows and everything works great again.
  22. Replies
    84
    Views
    10,349

    That's about 75% of this job sometimes. Should...

    That's about 75% of this job sometimes.

    Should not need BBMD or FDR with two devices on the same subnet. Assuming neither device has protection against it you might create a broadcast storm.
  23. You've got a quote in that zip. Virus total...

    You've got a quote in that zip.

    Virus total seems happy with this, nothing detected.
  24. Replies
    84
    Views
    10,349

    I'm going to guess there's a settings menu...

    I'm going to guess there's a settings menu somewhere. I don't see a manual posted, ask them for it?
  25. Replies
    84
    Views
    10,349

    Vendor website? ...

    Vendor website?
    https://bravocontrols.com/shop/tstat8-bacnet-thermostat/
  26. Replies
    84
    Views
    10,349

    Solid receive light is generally a sign the...

    Solid receive light is generally a sign the polarity is backwards. Needs to be + to + and - to -.

    It came with a device ID and there should be some method for changing it, that's required.
  27. Replies
    84
    Views
    10,349

    You mean YABE on ethernet can't discover the...

    You mean YABE on ethernet can't discover the device on MS/TP under the router?

    One thing I noticed is the newer routers don't seem to have any MS/TP LED activity for just passing the token, just...
  28. Replies
    46
    Views
    1,127

    Thinking outside the box could you simply put in...

    Thinking outside the box could you simply put in a IP router? New IP on the WAN side and old IP on the LAN side. Make the LAN subnet work with the old IP address scheme and declare your existing...
  29. Replies
    25
    Views
    1,173

    Automated logic has a little app you can use to...

    Automated logic has a little app you can use to come up with some decent numbers, it's based on the Ziegler-Nichols calculation and it's called tuminator. You first set up some basic trending and PID...
  30. Furthermore after they update to v7 they won't...

    Furthermore after they update to v7 they won't need JAVA in the browser for trend graphs anymore. This will make IT security really happy.

    Also v7 works with all browsers, not just Internet...
  31. First off they are replacing the server because...

    First off they are replacing the server because the OS is unsupported. The same goes for WebCTRL, that version hasn't been supported for many years now. Why are they not upgrading it? This is your...
  32. I also had trouble getting in this afternoon....

    I also had trouble getting in this afternoon. Edit; getting 502's right now on the controls, pro forum.


    Genuine question; how are you planning to deal with the end of life issue? Why not stick...
  33. Carrier open controllers should have a place for...

    Carrier open controllers should have a place for a BT485, that can handle bias and termination. As one of those is likely end of line might want to check into that.



    Very interesting! Start a...
  34. Replies
    7
    Views
    541

    Thank you for the efforts but how are you...

    Thank you for the efforts but how are you planning to deal with the end of life issue?
    ...
  35. Replies
    3
    Views
    263

    AAON VCMX WSHP Tulsa loop water shutdown

    Please check my thinking on this but I'm not finding a way to positively shut the unit down on loop a water not OK situation. Am I blind or is this some sort of gross oversite? Best I can come up...
  36. Thread: test

    by MaxBurn
    Replies
    6
    Views
    413

    A picture.814470 A file 814471

    A picture.814470

    A file
    814471
  37. Replies
    3
    Views
    274

    I can't believe how the sensors from these THREE...

    I can't believe how the sensors from these THREE companies look so much like each other. Wonder what the story is there?
  38. Replies
    5
    Views
    290

    I'm going to as for clarification on this. By...

    I'm going to as for clarification on this. By some definitions the building management system is the remote monitoring software and has that data, they can all handle various forms notifications...
  39. Thread: VPN Routers

    by MaxBurn
    Replies
    54
    Views
    3,697

    Mostly commercial though churches are pretty...

    Mostly commercial though churches are pretty close to residential in a lot of ways, ways they probably shouldn't be but still.
  40. Replies
    10
    Views
    396

    If you have temperature and humidity you can get...

    If you have temperature and humidity you can get enthalpy, there's a standard converter block for that. Temp and humidity sensors don't last forever, like everything else. Enthalpy is still the way...
  41. Replies
    10
    Views
    396

    Take a look in EquipmentBuilder and see if any of...

    Take a look in EquipmentBuilder and see if any of the published templates make sense for your situation.

    Depending on your version these may be newer; ...
  42. That's the only big deal part of it. This holds...

    That's the only big deal part of it. This holds big liability.
  43. Replies
    3
    Views
    274

    That's worth calling Bapi and Maymac to see if...

    That's worth calling Bapi and Maymac to see if someone OEM's it and what it is. I'm not sure of the relationship there or why the two companies sensors look like each other.

    LOL at the price of...
  44. Replies
    8
    Views
    449

    Maybe take the two touch screens apart and put...

    Maybe take the two touch screens apart and put the working screen on the working screen controller?
  45. Replies
    18
    Views
    1,765

    Come to think of it I did run across some AAON...

    Come to think of it I did run across some AAON units that wouldn't discover in ALC a short while back. Same issue, controllers discovered fine and points would not discover. Thought I had a message...
  46. CompTIA is nice that it isn't tied to any...

    CompTIA is nice that it isn't tied to any particular vendor. I've viewed prof messer videos plenty of times in the past. Now that I'm thinking about it I really should go for my Network+/Security+...
  47. Replies
    11
    Views
    506

    Found a map to help you locate a BSides (and...

    Found a map to help you locate a BSides (and other groups) near you.

    http://www.hackermaps.org/
  48. Thread: VPN Routers

    by MaxBurn
    Replies
    54
    Views
    3,697

    OpenVPN is one of a handful of VPN protocols it...

    OpenVPN is one of a handful of VPN protocols it supports.
  49. Thread: VPN Routers

    by MaxBurn
    Replies
    54
    Views
    3,697

    Yet another option if you want a GUI based...

    Yet another option if you want a GUI based OpenVPN server solution. I haven't used it, just stumbled across it.

    https://www.softether.org/
    https://www.softether.org/3-screens/1.vpnserver...
  50. Thread: VPN Routers

    by MaxBurn
    Replies
    54
    Views
    3,697

    That's how OpenVPN clients work, they are the...

    That's how OpenVPN clients work, they are the ones that reach out to the passive listening server. This is not at all like a IPsec site to site VPN where both ends need to be visible to the other.
    ...