Search:

Type: Posts; User: hearthman

Page 1 of 19 1 2 3 4

Search: Search took 0.14 seconds; generated 4 minute(s) ago.

  1. Replies
    7
    Views
    7,477

    The switches in the handheld transmitter must...

    The switches in the handheld transmitter must match the printed circuits in the receiver. A cut circuit is matched by moving the corresponding dip switch 'off'. This remote works by radio frequency....
  2. Replies
    1
    Views
    186

    402.4.1 Longest length method. The pipe size for...

    402.4.1 Longest length method. The pipe size for each section of gas piping shall be determined using the longest length method of piping from the point of delivery to the most remote outlet and the...
  3. Replies
    9
    Views
    25,588

    Yes, contact FHH with the model and serial...

    Yes, contact FHH with the model and serial number. They can order any parts needed as well as provide service.

    FYI, I worked as a paramedic in Richland Co EMS for 9 yrs.
  4. Replies
    11
    Views
    420

    Can NOT use 1/2" . Thx. Flying fingers. Nah,...

    Can NOT use 1/2" . Thx. Flying fingers.

    Nah, the code doesn't really state a flat PD for fittings. They just say regardless of what you do, the pressure drop from the Point of Delivery to the...
  5. Replies
    11
    Views
    420

    The Longest Run method for this case would...

    The Longest Run method for this case would calculate as follows:
    Table G2413.4(1) in the IRC or 402.4(2)) in the IFGC. They're the same basic tables as in NFPA 54 NFGC since they both paid GAMA for...
  6. Definitely contact the mfr. for an OEM part and...

    Definitely contact the mfr. for an OEM part and have a qualified tech make the changeout. Since this is a study, you'll want to get a really solid baseline with the standing pilot then the IPI. I'd...
  7. Check with the mfr. some do/ most don't. You can...

    Check with the mfr. some do/ most don't. You can go freestyle and cobber something together that will work but if something goes wrong, YOU become the mfr. of record and if occupants/guests are hurt,...
  8. Karl Meninger was asked to define mental health:...

    Karl Meninger was asked to define mental health:

    Definition • Menninger (1946, p. 2) says, “Let us define mental health as the adjustment of human beings to the world and to each other with a...
  9. Replies
    16
    Views
    1,415

    Fix your lint screen on your machine. Also, if...

    Fix your lint screen on your machine. Also, if there's that much in the duct you surely have a mess inside your dryer blown all around. Get a large appliance tech in to open it up and fit it with a...
  10. Tankless require a LOT of gas. Typically a 2 psi...

    Tankless require a LOT of gas. Typically a 2 psi system. If you don't use a 2 psi system, you'll need a very large diameter, expensive gas line to serve that flame thrower. They can bottom out the...
  11. https://www.proknee.com/model-0714-standard-kneepa...

    https://www.proknee.com/model-0714-standard-kneepad
    These are what a lot of flooring guys wear. I solved this problem recently: I bought a new pair of knees. Now I'm not ever allowed to kneel...
  12. Replies
    39
    Views
    5,017

    Have you measured the O2 at the ceiling for...

    Have you measured the O2 at the ceiling for general leak detection? He rises and displaces the O2 so most MRIs have O2 sensors at the ceiling to detect He leaks.
    Just thought I'd toss that out....
  13. Replies
    47
    Views
    7,309

    Nice work Tom!

    Nice work Tom!
  14. Sorry man but based upon what you've described I...

    Sorry man but based upon what you've described I don't see how to help. Really wish I could. Shop around the Nat'l Fireplace Inst. at nficertified dot org to find a local tech certified in gas....
  15. make and model?

    make and model?
  16. Draft is really just a pressure gradient. If the...

    Draft is really just a pressure gradient. If the heated stack gases lighten sufficiently so they are less dense than the surrounding air, the stack gases will rise due to the slight pressure gradient...
  17. Please read the Site Rules: This is NOT a DIY...

    Please read the Site Rules: This is NOT a DIY site. We can give general information for you to discuss with your pro but this is not the DIY Network.
    Thanks,
  18. Returns must be min. 10ft from furnace and cannot...

    Returns must be min. 10ft from furnace and cannot be located in a small volume space. See the IRC for the simple formula. Supply and returns must be sized for the space and balanced. Entire duct...
  19. Replies
    3
    Views
    350

    The Intellifire system has the capability of a...

    The Intellifire system has the capability of a standing pilot they refer to as a "cold climate" function. This is used in cabins and cold areas to provide a tad of heat when not firing. I've seen it...
  20. Is it a steel tank or diaphragm tank? Big...

    Is it a steel tank or diaphragm tank? Big difference. If steel tank, make sure it isn't waterlogged. Must have an air space.

    If diaphragm, make sure diaphragm not ruptured and it is charged...
  21. Replies
    31
    Views
    1,975

    Can someone provide a model # to this "sealed...

    Can someone provide a model # to this "sealed combustion 80% furnace" ?
    TIA,
  22. Replies
    5
    Views
    469

    Where a DV is installed inside the thermal...

    Where a DV is installed inside the thermal envelope of the building, as long as the firestop assembly is caulked it shouldn't have problems. These units are tested to 50 Pascals positive pressure,...
  23. Replies
    3
    Views
    350

    Could be bad remote or receiver/ module. Provide...

    Could be bad remote or receiver/ module. Provide model and serial # to HHT dealer you bought it from and ask them to open a case file in their FQCS or Field Quality Claim System. That gets it on the...
  24. Replies
    31
    Views
    1,975

    It's two separate liners. One for positive vent...

    It's two separate liners. One for positive vent pressure AL29-4c listed under UL 1738 for CAT IV gas appliances co-axially mounted inside a suitable chimney, liner or B-vent for CAT I gas under UL...
  25. Replies
    31
    Views
    1,975

    The FNS 80/90 system has been out since March of...

    The FNS 80/90 system has been out since March of 2015. Check with the mfr. of your appliance in question. They may sign off on it once presented an info. sheet. I know the Fas-N-Seal product line was...
  26. Replies
    31
    Views
    1,975

    80/90. If you need tech support request Dale...

    80/90. If you need tech support request Dale Menges at Dura-Vent. I just chatted with him about this product while at EXPO in Dallas last week. Should solve your problem.
  27. Replies
    31
    Views
    1,230

    You can't tell much by looking at flames. You...

    You can't tell much by looking at flames. You need someone certified to perform combustion analysis to know what's going on and to guide any tuning.
  28. Replies
    120
    Views
    16,755

    I have a Fluke 116 DMM and a 1587 megger/...

    I have a Fluke 116 DMM and a 1587 megger/ insulation tester but my go to meter is my Fieldpiece sc56. No problems with any of them .
  29. Check the manual again. Some brands have put...

    Check the manual again. Some brands have put instructions to remove the glass before attempting to ignite the pilot with LP gas.
  30. Replies
    6
    Views
    1,194

    In the US, any insulation for ducts must be...

    In the US, any insulation for ducts must be listed to UL 181 and rated 250°F. Inside the building it must be covered with a sheathing to protect it from impact or ignition.
  31. It's about $1K for a copy of Z21.88. Since it...

    It's about $1K for a copy of Z21.88. Since it came out in 1995, glass enclosed fireboxes must dropout within 30 seconds of pilot flame extinguishment. You'll see them referred to as "quick dropout"...
  32. Replies
    36
    Views
    1,394

    Dip Switch posted clickbait. No substantiation...

    Dip Switch posted clickbait. No substantiation for his claim. Not one example. Bashing because he's frustrated to be on the wrong side with no facts, no successes, nothing constructive or righteous...
  33. Thread: Cohen

    by hearthman
    Replies
    198
    Views
    4,394

    Congress busts a guy for committing perjury to...

    Congress busts a guy for committing perjury to them then brings him back to perjure himself more to get an expected outcome then act as if this new testimony is true and reliable knowing he was set...
  34. You are describing two different units. One...

    You are describing two different units. One minute you are discussing a millivolt valve with standing pilot then you're taking about an intermittent pilot ignition with a control module. You really...
  35. Thread: I'm back

    by hearthman
    Replies
    17
    Views
    971

    Give me a call at Chimney Cricket in Woodlyn. ...

    Give me a call at Chimney Cricket in Woodlyn.

    Thx for all the welcomes back guys!
  36. Replies
    12
    Views
    3,980

    A vented logset requires the damper be blocked...

    A vented logset requires the damper be blocked wide open to maintain a stated "minimum permanent net free opening" which usually starts around 50 square inches. That equates to an 8" flue. Wide...
  37. Replies
    4
    Views
    1,149

    Dude you need to step away and quite playing...

    Dude you need to step away and quite playing junior mad scientist. You are waaay over your head and about to get hurt. You are also exposing anyone who lives there or could enter your home, such as...
  38. Replies
    4
    Views
    1,149

    Valves all have a tiny allowable leakage per ANSI...

    Valves all have a tiny allowable leakage per ANSI stds. However, fugitive gas igniting outside the combustion chamber is a hazard. Shut down the fireplace until a pro can diagnose and correct the...
  39. Replies
    6
    Views
    435

    There's a rating plate in the valve compartment...

    There's a rating plate in the valve compartment on a metal tag.
  40. Replies
    6
    Views
    435

    Any HG dealer will have a GFK-160a dual squirrel...

    Any HG dealer will have a GFK-160a dual squirrel cage blower. The instructions that came with the MLT will show you where it plugs in. The MLT does all the work. This fan simply sits on magnetic...
  41. Replies
    24
    Views
    2,323

    You can use crude air flow indicators to...

    You can use crude air flow indicators to demonstrate the direction of flow where there is a sufficient pressure gradient coupled with a suitable shunt to allow sufficient flow to move your indicator....
  42. Thread: I'm back

    by hearthman
    Replies
    17
    Views
    971

    I'm back

    When my old computer took a dump, I had forgotten my password to H-talk. I had been heavy into some rather lively discussions that were quite frankly taking up too much of my life. Fast forward to...
  43. Replies
    5
    Views
    1,301

    Have your return ducts properly sealed, esp. in...

    Have your return ducts properly sealed, esp. in the basement. Have a pro measure the pressure differential in Pascals so that the basement is neutral. Closing supply vents while leaving a return open...
  44. Replies
    115
    Views
    18,501

    https://www.youtube.com/watch?v=jFFRpxFkpcM ...

    https://www.youtube.com/watch?v=jFFRpxFkpcM

    This is from PaysonHVAC on H-talk. He was forced off by his boss but is the originator of the "Run Cap Bandit". He's from Arizona.

    HTH.
  45. Thread: Trump nausea

    by hearthman
    Replies
    92
    Views
    3,852

    The AngryMouthfull is following typical liberal/...

    The AngryMouthfull is following typical liberal/ Progressive patterns by diverting the discussion from the facts of the case with flowery rhetoric in the vain attempt to justify his own miserable...
  46. Thread: Trump nausea

    by hearthman
    Replies
    92
    Views
    3,852

    Listen CrazyChewy, it's bad enough you...

    Listen CrazyChewy, it's bad enough you denigrating ARP members calling them names but to refer to Trump as the Messiah is offensive to us Christians. Yes, I'm proud to call myself one. What a...
  47. Thread: Trump nausea

    by hearthman
    Replies
    92
    Views
    3,852

    The Trumpster actually holds NATOs collective...

    The Trumpster actually holds NATOs collective feet to the fire forcing them to ante up and the libtards find fault with that. Refresh my memory please: what was NATOs response to Putin invading the...
  48. Replies
    13
    Views
    1,806

    https://www.reedmfgco.com/en/resources/training-vi...

    https://www.reedmfgco.com/en/resources/training-videos/plastic-pipe-tools/solutions-kits/
  49. Replies
    2
    Views
    2,293

    You need to hire a pro to perform a level II...

    You need to hire a pro to perform a level II inspection first. That will determine the suitability of the chimney even if you blow out the steelform fireplace and rebuild the firebox with masonry....
  50. If you want to be "fair and balanced" let's...

    If you want to be "fair and balanced" let's compare how BHO was treated with The Trumpster:
    BHO broke over 78 federal laws, suspended the Constitution, committed murder, aided and abetted out...
Results 1 to 50 of 931