  1. Replies
    33
    Views
    894

    What?…didn’t you do what we use to do when we had...

    What?…didn’t you do what we use to do when we had attic Air Handler installed in a hot attic, once lineset was hooked up and soft soldered, ( R22 ) we use to remove takeoffs ( or not install them...
  2. Maybe we should not say anything to the...

    Maybe we should not say anything to the Refrigeration Guys/Gals.. as it would say HVAC/R to include them, but it does not…:whistle:
  3. Today,.. ...

    Today,..

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwjYtOP1uavxAhVNQ80KHYWuAMkQFjAEegQIAhAD&url=https%3A%2F%2Fhvactechday.com%2F&usg=AOvVaw3Wo6vM7FZBsnsj1FOzojWT

    ...
  4. Replies
    2
    Views
    230

    Make sure to register your system as you get a...

    Make sure to register your system as you get a 10/10 compressor, parts and coil warranty once registered. Drops to 5/5 including coil if never registered.
  5. Replies
    33
    Views
    894

    Still see that listed as a requirement on many...

    Still see that listed as a requirement on many occasions ( AHRI web-site ) after the coil model number says + TDR.

    Back in the dinosaur age that’s how they made your system a higher seer rating.....
  6. New install, you should have a labor warranty to...

    New install, you should have a labor warranty to fix your problem, need a senior Tech. Also need to check in defrost to make sure it initiates a defrost, and terminates a defrost and if it’s wired to...
  7. Throw in a correctly sized simplistic troublefree...

    Throw in a correctly sized simplistic troublefree piston ( if it possible to unscrew TXV ) to install piston, especially if it’s a lower SEER unit is a suggestion. Equalization of refrigerant during...
  8. Replies
    11
    Views
    321

    Doesn’t seem to stop people from purchasing a...

    Doesn’t seem to stop people from purchasing a product from a particular country, some manufacturers have units that are assembled/manufacturered/made in China 100% and exported to the USA, parts come...
  9. Replies
    11
    Views
    321

    Looks like the two stage gives you the higher...

    Looks like the two stage gives you the higher SEER and EER, should qualify for rebates and Federal Tax Credits, certainly that alone may narrow the cost difference between the two. 16 SEER and 12.50...
  10. Replies
    11
    Views
    321

    https://www.ahridirectory.org/Search/QuickSearch?c...

    https://www.ahridirectory.org/Search/QuickSearch?category=8&searchTypeId=3&producttype=68&SubmenuId=3500&ProgramId=68

    leaning towards his quote when I noticed one of his quotes uses a Lennox Elite...
  11. Replies
    37
    Views
    973

    Ducted Heat Pumps are overrated in New England...

    Ducted Heat Pumps are overrated in New England IMO, maybe not so much as a Hybrid thou, but for your main Heat yes, been installing them, and servicing them for 45 + years so right or wrong I’m...
  12. Replies
    11
    Views
    321

    Ask them to give you the AHRI number to prove...

    Ask them to give you the AHRI number to prove they are bidding matching systems, if they give you the number that’s one plus that they know what they are doing,…or at least care enough to bid...
  13. Replies
    37
    Views
    973

    What do you have for a outdoor unit now? If it’s...

    What do you have for a outdoor unit now? If it’s a Heat Pump ( ASZC16 or 18 ) just run it in cool mode.

    The ASXC16 is the better choice of what?

    In your initial post #1 they where suppose to...
  14. Replies
    23
    Views
    1,087

    Increased SEER and EER rating also…:whistle:

    Increased SEER and EER rating also…:whistle:
  15. Replies
    23
    Views
    1,087

    Increased SEER and EER rating also :whistle:

    Increased SEER and EER rating also :whistle:
  16. Hire a Company to check your subcooling to this...

    Hire a Company to check your subcooling to this install guide, as it gives the perimeters
    ...
  17. Replies
    1
    Views
    151

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&so...

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwjuzpTH9qTxAhWTbc0KHbrcA1cQFjAKegQIHRAD&url=https%3A%2F%2Fwww.stylecrestinc.com%2Fmanufactured-housing-products%2Fabout-revolv%...
  18. Looks to have a check TXV metering device?. It’s...

    Looks to have a check TXV metering device?. It’s definitely not a AHRI match as you have two completely different manufacturers system, but thinking if you get the metering device correct and dial in...
  19. Replies
    37
    Views
    973

    Post 32 what would be the reason to ask about the...

    Post 32 what would be the reason to ask about the difference between the ASXC18 and ASXC16 as I’m reading it you have the ASXC16.

    They would not necessarily need to install a field install filter...
  20. Replies
    37
    Views
    973

    Possibly higher EER? check AHRI ratings, with the...

    Possibly higher EER? check AHRI ratings, with the exact indoor section to either models, the specifications sheet for the ASXC18 says the outdoor fan is a two speed ECM motor whereas the ASXC16 uses...
  21. Replies
    23
    Views
    1,111

    Why not get a good load on the indoor first, 64...

    Why not get a good load on the indoor first, 64 return seems like a very low load situation. Some manufacturers say between 70-80 degree. Maybe 75degree+ to start, you got a furnace to do that....
  22. Novice idea, many positives thou, away from the...

    Novice idea, many positives thou, away from the elements ( New England weather ) didn’t need a head master control, had its own protection kit, if it had a CCH and it failed who cares it’s still warm...
  23. You got a major mismatch system, a 25 year old...

    You got a major mismatch system, a 25 year old 8/10 SEER coil hooked to a 16 SEER rated outdoor unit for starters. Your indoor coil ( from 10 SEER 4 ton ) is now a 3.5 ton 14+SEER rated hooked to a...
  24. Replies
    5
    Views
    231

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&so...

    https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwiClrnNq5_xAhVXa80KHZEGDBQQFjACegQIAhAD&url=https%3A%2F%2Fwww.shareddocs.com%2Fhvac%2Fdocs%2F1009%2FPublic%2F01%2F24VNA6-25VNA4...
  25. Replies
    62
    Views
    1,355

    My family member are pretty healthy, his wife and...

    My family member are pretty healthy, his wife and one of his child was on that program, it worked out well for them, except one time when his daughter was hospitalized for a stomach infection, she...
  26. Replies
    62
    Views
    1,355

    “insurance companies don't just raise your...

    “insurance companies don't just raise your premium they increase everyone's, I eat right,exercise and live a healthy lifestyle yet I'm being penalized cause all the fat fu(Ks that eat junk food day...
  27. Replies
    11
    Views
    400

    Doubt it, ( at least with a Goodman coil ) you...

    Doubt it, ( at least with a Goodman coil ) you can check yourself.

    https://www.ecomfort.com/manuals/e9e287c0b736172b328930f35e9c210a.pdf

    https://www.acwholesalers.com/manuals/MBVCSpecs.pdf ...
  28. Replies
    4
    Views
    277

    Third Contractor seems unprofessional to a degree...

    Third Contractor seems unprofessional to a degree if dissing another brand, just to sell what they carry. Sounds like a sales Tech.

    Ask them for AHRI matched indoor coil to outdoor unit to see...
  29. Replies
    7
    Views
    200

    Then why did you dislike my post? or are you...

    Then why did you dislike my post? or are you reeling me in?
  30. Replies
    7
    Views
    200

    Put fan ( at thermostat ) from fan auto mode to...

    Put fan ( at thermostat ) from fan auto mode to fan ON, if blower runs, then use the A/C and call for service, if blower motor does not come on, call for service sooner..
  31. Replies
    62
    Views
    1,355

    Doesn’t fly in the Military, especially if your...

    Doesn’t fly in the Military, especially if your working towards a pension, random drug testing at any time…..
  32. Replies
    33
    Views
    894

    Delay on break as mentioned for safeties, another...

    Delay on break as mentioned for safeties, another example bypassing a LPC ( wired in parallel with the switch ) to prevent cycling on that switch until refrigerant pressures build up…thinking used...
  33. Replies
    33
    Views
    894

    Delay on break is preferred on Heat Pump...

    Delay on break is preferred on Heat Pump applications…especially in a cold state,…just saying
  34. ARUF is not a electric furnace per se it’s a Air...

    ARUF is not a electric furnace per se it’s a Air Handler with a optional heater kit installed. Electric furnace does not have a built in A/C coil, somewhat similar to a modular blower….at least...
  35. Replies
    13
    Views
    327

    Yes I remember reading something about the 60...

    Yes I remember reading something about the 60 days limit,..Thankx for mentioning,…
  36. Replies
    37
    Views
    973

    https://www.ecomfort.com/manuals/CoilSpecs.pdf ...

    https://www.ecomfort.com/manuals/CoilSpecs.pdf

    Check yourself..
  37. Replies
    13
    Views
    327

    Possibly your running at a different blower speed...

    Possibly your running at a different blower speed when running fan ON vs when running with A/C. Can you tell if there is a difference in blower speeds between them?

    “Upstairs unit is a Train...
  38. Replies
    30
    Views
    486

    Says it’s rated at 13/14 SEER so you got a decent...

    Says it’s rated at 13/14 SEER so you got a decent energy efficient unit, says it’s a 2.5 ton unit
    ...
  39. Replies
    30
    Views
    486

    That’s your furnace number, says it’s a 92%...

    That’s your furnace number, says it’s a 92% efficiency ( which is nice! ) and has a PSC blower motor
    ...
  40. Replies
    30
    Views
    486

    That’s your coil number, the model number of the...

    That’s your coil number, the model number of the furnace is inside the main access panel. Don’t need thou as you say it’s 10 years old and a different brand. Thinking your furnace is a 80% as you...
  41. Replies
    30
    Views
    486

    That means they can’t prove the AHRI number or...

    That means they can’t prove the AHRI number or they can ,…but….your not going to get anywhere near those rating IMO and guarantee the rated efficiency on some of the quotes as unless the furnace is a...
  42. Replies
    30
    Views
    486

    Doubt they can come up with AHRI numbers for #2...

    Doubt they can come up with AHRI numbers for #2 and especially #3 ( to give you the rated 16 and 18 SEER ) thinking if your paying for a rated SEER and are under the impression of getting those...
  43. Replies
    20
    Views
    435

    If the leak is indeed at the indoor coil, they...

    If the leak is indeed at the indoor coil, they should be able to pinpoint it pretty close with a electronic then even prove it with soap to show you.

    If your the original registered owner you...
  44. Replies
    30
    Views
    486

    #5 Bid with the EL16 only gives 14 SEER and 12.20...

    #5 Bid with the EL16 only gives 14 SEER and 12.20 EER AHRI number 10563051

    #4 Bid with the ML14 gives 14 SEER and 12.20 EER AHRI number 10563055

    Same efficiency ratings but your paying more for...
  45. Replies
    2
    Views
    203

    Put a field install 5 minute off cycle delay on...

    Put a field install 5 minute off cycle delay on the common cool wire outside,..you can set your thermostat delay if you have that option ( if set up at the thermostat ) to a minimum position.
  46. Replies
    30
    Views
    486

    Ask for a AHRI number to prove your getting those...

    Ask for a AHRI number to prove your getting those advertised SEER ratings a AHRI number will also give EER ratings. If any system meets the minimum threshold for rebates or the Federal Tax Credits...
  47. You would not have noticed it was a 90, ( a long...

    You would not have noticed it was a 90, ( a long radius 90 at that ) or a kink if not for the insulation rotting off…
  48. Replies
    9
    Views
    286

    I had them eat ( mice anyway ) my ductwork all...

    I had them eat ( mice anyway ) my ductwork all the way through, starting with the thin aluminum foil outer skin then the 1” thick pressed fiberglass ( fiberboard ) in my other house, that was...
  49. Replies
    9
    Views
    286

    Non-Metallic Liquidtite,…they’ll just move to...

    Non-Metallic Liquidtite,…they’ll just move to your circuit board(s) afterwards and urinate and deficate and eat those board(s) and wiring, not necessarily in that particular order thou, so you may...
  50. Replies
    2
    Views
    259

    Oil runs hotter than gas, at least one...

    Oil runs hotter than gas, at least one manufacturers sell high temperature drain pans for when they are used on oil furnaces.

    Here’s an example of what one manufacturer wants to see after the high...