  1. Supco recorder, Field Assist cable and dongle, IVu restore disk and thumb drives

    make an offer
  2. Carrier, Hoshizaki, carrier field assist cable, supco temp recorder

    make me offers
  3. Replies
    29
    Views
    4,198

    4.2 tools disc

    I can get you a Tools V4.2 disc. go to my profile and send me a email
  4. Replies
    9
    Views
    1,712

    i had problems with the 4.2 ivu after 3 or 4...

    i had problems with the 4.2 ivu after 3 or 4 years running. it would not connect to devices. Did you use service tool to actually see if you have the bus linked to devices
  5. Replies
    29
    Views
    4,198

    4.2 tools

    sorry i threw out the 4.2 tolls disc Had problems with the black box ivu the new ones are smaller and will last longer they tell me.
  6. Replies
    11
    Views
    1,600

    and I have 3.0 and 3.1 software

    and I have 3.0 and 3.1 software
  7. Replies
    11
    Views
    1,600

    usb key

    usb key
  8. Replies
    11
    Views
    1,600

    I am pretty sure I have key ,software, carrier...

    I am pretty sure I have key ,software, carrier telilink, and rs-485 converter.
    Make me a offer
  9. Replies
    0
    Views
    689

    Carrier Service tool V Kit

    I have one 33CNNSTKIT-01 Version 2.2 brand new in box
    asking $1500.00
  10. Replies
    0
    Views
    779

    comfortview 3.0 software access key

    I have comfortview 3.0 disc, access key and 2- R-232 to R-485 converters
    I want 300.00
  11. Replies
    1
    Views
    478

    carrier sch with field assist

    Maybe i am not looking in the right place and need direction.
    Have a new job I started up there are two rooftop units. Each unit has a open VAV controller. One unit has four VAV boxes, and the other...
  12. Replies
    29
    Views
    4,198

    Are you looking for the Tools V4.2 i-Vu CCN...

    Are you looking for the Tools V4.2 i-Vu CCN tools disc only?
    If so drop me a email and I will send one out to you.
    As far as upgrading to 6.0 I have a list of what i-Vu units you can do. Some you...
  13. Thread: carrier ccn

    by fac 213
    Replies
    5
    Views
    1,650

    If the stats have the rotary switch I do not...

    If the stats have the rotary switch I do not think you can do it. But if you upgraded the stats you can get a link with a i-vu and get it to work. I think you had the first service tool and the...
  14. Do you still have 2- 33csps-02 pressure...

    Do you still have 2- 33csps-02 pressure transducers if so how much.
    Also will need two 33csbc-00 bypass controllers . Also will need a price.

    Thanks
  15. Replies
    6
    Views
    1,526

    confortview 3.1

    I want to thank the 126 people who viewed my question with no response. I guess since I do not post often I am not worthy of a response, or I am not in you inner circle. As to JC1man i see no reason...
  16. comfortview 3.1 running in widows 7 xp mode

    I loaded 3.1 in the xp mode. I have one issue that I can not seem to figure out. If I lose power to the computer and restart it I get a comm failure next to devices. I have to right click job then to...
  17. Replies
    6
    Views
    1,717

    Are you talking about a premierlink in the...

    Are you talking about a premierlink in the rooftop unit. If so I have had the same problem, and also in cooling. I talked to Carrier and they suggested installing heat and cool isolation relayswhich...
  18. rc5115 Do you still have the 33csdca090 damper...

    rc5115
    Do you still have the 33csdca090 damper motors and if so how much.

    Thanks
  19. Thread: Windows 8

    by fac 213
    Replies
    16
    Views
    4,138

    Ok Windows 8 seems to have issues, but has...

    Ok Windows 8 seems to have issues, but has anybody tried to load carrier service tool 2.2 onto windows 8 ? And thanks for the imput.
  20. Thread: Windows 8

    by fac 213
    Replies
    16
    Views
    4,138

    Windows 8

    Hi I am looking to get a new lap top. It comes with windows 8. Has anybody tried setting up carrier service tool on windows 8 yet. The version of service tool I have is 2.2.
    Thanks
  21. Replies
    1
    Views
    1,654

    Johnson Fan Controller

    I have two new P66AAB-39C single Condenser Fan Speed
    Controllers. Trane part number-436704290100. Operating range
    320 to 410 psig. Want to sell them togehter. Make me a reasonable offer.
  22. Thread: 33cst carrier

    by fac 213
    Replies
    1
    Views
    723

    33cst carrier

    On a 33cst monitor stat in config 1, there is a override time limit, and a timed override hours. Does anyone know what the difference is. I looked in the config book and can not find it. Thanks for...
  23. Replies
    0
    Views
    1,255

    York Rooftop info

    I have two York Rooftop units, that I am going to replace. Problem is the town inspector wants to know the weight of the unit, and the weight of the new unit, with the curb adabter. I have the cut...
  24. Replies
    5
    Views
    2,896

    Carrier varislide ecomonizers

    I have a few units that have the old slide econonizers. I called carrier to order the drive screw that connects to the motor and moves the damper up or down. Carrier can not find a part number. Does...
  25. Replies
    41
    Views
    12,334

    I think the kit Trane provides to correct the...

    I think the kit Trane provides to correct the failures is KIT15855 ( Trane kit number). I called for a price, quite expensive for some wires, and a contactor.
    Has anyone installed this kit ? Any...
  26. Replies
    41
    Views
    12,334

    Thanks for the info. I will check with my Trane...

    Thanks for the info. I will check with my Trane distributor tomorrow. I thought about installing a 24v isolation relay to break the 2 legs going to the cfm. The relay woud be powered from w1 going to...
  27. Replies
    41
    Views
    12,334

    I know the kit and wiring harness exists for the...

    I know the kit and wiring harness exists for the smaller Trane units with the negative gas pressure set up, but I am refering to a 12.5 ton voyager rooftop unit. If they did make a change , where can...
  28. Replies
    0
    Views
    944

    Old 20 ton York

    I have three york, DACW240 rooftop units. Does someone have the sequence of operations for the heat section. I have the wiring diagram. Thanks
  29. Thread: 25 Ton Voyager

    by fac 213
    Replies
    28
    Views
    4,770

    I believe trane uses a 2 pole contactor for the...

    I believe trane uses a 2 pole contactor for the Evap motor, even though it is
    3 phase. Did you checvk the Pri tap on the transformer to see if it matches the incomming voltage. Is the Transformer...
  30. Replies
    17
    Views
    4,873

    fxb80, I have two floppy's for the old service...

    fxb80,
    I have two floppy's for the old service tool 4 version 1.0. Is that what you are looking for? My e-mail is in my profile.
  31. Replies
    4
    Views
    1,627

    3 ton unit

    I am looking for one unit. How much are you selling it for. My e-mail is in my profile. Please let me know.

    Thanks
  32. Thread: Carrier

    by fac 213
    Replies
    6
    Views
    1,641

    Zone Controllers

    Acomo

    I have two Zone controllers, one bypass controller, two temp stats. Took them out of a job that had the old ACS program. They might be locked, I can not remember if I removed the lock with...
  33. Replies
    6
    Views
    5,409

    Had the same problem. The smoke detectors were...

    Had the same problem. The smoke detectors were system sensor type. The came factory installed in new Trane units. The units (2) serviced the kitchen area. They keep tripping and then the Fire Trucks...
  34. Replies
    16
    Views
    16,338

    Hope this helps I have not used it but it sounds...

    Hope this helps I have not used it but it sounds good


    Industrial/Commercial HVAC condensate pans are a common source of problems facing healthcare facilities. The two main issues being Indoor...
  35. Thread: Trane Varitrac

    by fac 213
    Replies
    3
    Views
    1,125

    Trane Varitrac

    I have a Trane Varitrac VAV system . It consists of two VAV boxes, and one bypass damper. Their is a control panel on the job and I can access Zone and system status and setup. The problem is the fan...
  36. Replies
    41
    Views
    12,334

    Sorry about the double post

    Sorry about the double post
  37. Replies
    41
    Views
    12,334

    Trane CBM failures

    I have had several CBM with the same problem, just running and no heat. Trane exchanged them under warranty. In fact they said hold on to the CBM
    they did no want it back. Today I had another CBM...
  38. Replies
    41
    Views
    12,334

    I have had several CBM with the same problem,...

    I have had several CBM with the same problem, just running and no heat. Trane exchanged them under warranty. In fact they said hold on to the CBM
    they did no want it back. Today I had another CBM...
  39. Replies
    7
    Views
    1,315

    Thanks r404a for the suggestions. It will take...

    Thanks r404a for the suggestions. It will take some doing, but I will find the leak. The machine is working like a champ right now. I still have the probe on the discharge line, and will stop every...
  40. Replies
    7
    Views
    1,315

    Went back to the nightmare job, the unit is FULL...

    Went back to the nightmare job, the unit is FULL of ice, and the discharge temp stayed below 200. There is a leak somewhere. I soaked the sol vales, access fittings, and all the rest with bubbles,...
  41. Replies
    7
    Views
    1,315

    Went back to the job today. The recorder showed a...

    Went back to the job today. The recorder showed a discharge line temp at 195 on the high end and 110 on the low end. Called the Tech guys at Manitowoc, and we determined the unit was low on gas. I...
  42. Replies
    7
    Views
    1,315

    BY1894N Remote Lockout on saftey limit 4

    Have a Manitowoc Ice Machine that Locks out on Saftey Limit 4 every once in a while. Pressures are 265-43 ( 265 taken at liquid line ) @ 80 outdoor temp on start up. Suction drops to 30 right before...
  43. Replies
    4
    Views
    3,050

    Go to honeywell.com I think you need a...

    Go to honeywell.com
    I think you need a vr8305q4146 two stage valve
  44. Replies
    23
    Views
    5,316

    Dgruber I have service literature and overhaul...

    Dgruber

    I have service literature and overhaul for Trane Semi Hermetic Compressors
    Model E. It might help you out if you plan to to do a overhaul. Send me a fax number, and I will send you the...
  45. Replies
    17
    Views
    2,245

    Ask Him to explain how you size sol valves. Alot...

    Ask Him to explain how you size sol valves. Alot of Techs think a B6 sporlan will work on a 1 hp system. (just a example)
  46. Replies
    48
    Views
    5,964

    Manitowoc 452 Ice Machine

    Might have a water valve that sticks open sometimes. You need to check the codes if this happens again to see what the machine is locking out on.
  47. Replies
    1
    Views
    983

    Trane Voyager Combustion Fan Failures

    I have a Trane 12.5 Ton Rooftop unit. I replaced the Combustion Fan Motor last April because the motor was always running. Today on a P.M. the motor was burned up . (you could see the windings...
  48. Replies
    32
    Views
    5,339

    Okay Mr Air 2 spare, Maybe I was not completely...

    Okay Mr Air 2 spare, Maybe I was not completely correct, when I said their might be the wrong piston. The correct name in a nozzle, Each Bohn coil comes with two. They are in a little plastic bag...
  49. Replies
    32
    Views
    5,339

    Your superheat seems high, if it a semi I try to...

    Your superheat seems high, if it a semi I try to get 20 Degrees min at the compressor.
    Seems like you might have the incorrect piston in the distributer. If you call bohn they will tell you the...
  50. Replies
    10
    Views
    1,987

    Maybe it is not a pump down system. Could it be a...

    Maybe it is not a pump down system. Could it be a rooftop unit with a low pressure time delay relay for winter start ? If so then the unit cold be low on gas, the TEV could be a problem, or the drier...
Results 1 to 50 of 62