Search:

Type: Posts; User: mh heating

Page 1 of 8 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    12
    Views
    2,522

    https://www.quick-sling.com/

    https://www.quick-sling.com/
  2. Replies
    19
    Views
    2,832

    I mainly use this. UV water tight but is more...

    I mainly use this. UV water tight but is more expensive

    https://www.southwire.com/products/ez-in-mini-split-cable-600-volt.htm
  3. Replies
    19
    Views
    2,832

    That would not fly in Oregon. Lines have to be UV...

    That would not fly in Oregon. Lines have to be UV treated. Communication wires needs Conduit with water tight connections. But the rest look great. Im liking the wall bracket for the duel fan.
    ...
  4. Replies
    13
    Views
    2,188

    Gree makes carrier and bryant

    Gree makes carrier and bryant
  5. Replies
    14
    Views
    3,356

    Gree used to make units for American...

    Gree used to make units for American Standard/Trane. But now Mitsubishi does. I guess Ameristar(Ingersal Rand) still uses it.

    Nice looking install. Is that connection for communication wire Water...
  6. Replies
    1
    Views
    797

    Recent Ductless Installs Part 3

    -----------------------------------------------------------------------------------------------------------------------


    The electrician I use, wanted a System Too

    24k 2 head H/P
    Lines...
  7. Replies
    1
    Views
    821

    Recent Ductless Installs Part 2

    Older farm house heated by natural gas. Removed that system due to constant rodent destruction. Installed a 2 system Ductless mini, with 3 heads each. Separated up and down stairs.
    30k & 36k with...
  8. Replies
    17
    Views
    3,054

    I'm working on one now, I'd should say the past...

    I'm working on one now, I'd should say the past year, a combination of two wall units with the mfz18 air handler attach to a 3 ton hyperheat
  9. Replies
    17
    Views
    3,054

    Recent Mini's

    1:1 12k Hyper heat

    http://www.use.com/media/2013/0129/3099268/p_024.jpg
    http://www.use.com/media/2013/0129/3099268/p_025.jpg

    3:1 & 2:1 HP 2.5 ton and 2 ton
    ...
  10. Thread: Triplets

    by mh heating
    Replies
    10
    Views
    3,433

    Thanks for the replys LOL, I posted this 15...

    Thanks for the replys

    LOL, I posted this 15 months ago. It was a big remodel but the original hvac installer came a repo'ed most the equipment and ductwork. The people still lived in it for...
  11. Replies
    18
    Views
    5,436

    So far the only complaint I would have with the...

    So far the only complaint I would have with the T-6, is the literature for home owners.
  12. Second picture look like it could be in a...

    Second picture look like it could be in a magazine. Great shots
  13. Replies
    10
    Views
    2,462

    Billg. I guess I didn't take a good enough...

    Billg. I guess I didn't take a good enough look at it when I tore it apart. I do know the when placing the drain on the right, it's placed outside of the cabinet. But one learns. I make an...
  14. Replies
    10
    Views
    2,462

    I don't know all the answers, didn't say I do....

    I don't know all the answers, didn't say I do. But thanks for the tip on gas line. As for the trap, clean out is a personal choice. State county city code does not require it. Sometime I add it...
  15. Replies
    10
    Views
    2,462

    45's are not required plus didnt have enough room...

    45's are not required plus didnt have enough room to connect to existing piping.
    As for drain, did you know goodman doesnt have a sealed system. Factory drain trap is an open design and will drain...
  16. Replies
    10
    Views
    2,462

    IF the drip leg is suppose to be at the lowest...

    IF the drip leg is suppose to be at the lowest point, it would have to be under the floor. So im not sure
  17. Replies
    10
    Views
    2,462

    Office Building

    Old furnace was shot. Original installer had the flue piping back words on concentric vent.

    Had to move unit back about 5 inches to meet front clearance code. Also replace A/c
    The only thing I...
  18. Thread: Triplets

    by mh heating
    Replies
    10
    Views
    3,433

    Triplets

    First up was a home that was remodeled back in 2005, Someone never paid the hvac bill, So I had to replaced the missing 3 air handlers, 2 ducts system, and three od unit. And sold them a mini split...
  19. Ductless are our friends, USE THEM

    Ductless are our friends, USE THEM
  20. Replies
    7
    Views
    2,922

    36000 btu a/c 45k heat

    36000 btu a/c 45k heat
  21. Replies
    7
    Views
    2,922

    That junction is the larger one out of two. This...

    That junction is the larger one out of two. This is their 5 head unit, they have a 3 head one too. This wasn't really a whole house setup, mainly the down stairs. The home has two other complete...
  22. Replies
    7
    Views
    2,922

    Lucky enough, two of the units used the existing...

    Lucky enough, two of the units used the existing drains from the old gas/ac system which are both above the junction/control box. The other was drain separate.
  23. Replies
    7
    Views
    2,922

    First Hyper Heat Ductless

    Three head hyper heat system from Mitsubishi. Only got pics of two heads, junction box and OD unit. Unit sized for another (future head in office)

    Main room, ran lines through existing return...
  24. Replies
    74
    Views
    27,538

    There is another difference between them. Compare...

    There is another difference between them. Compare the copper tubing within the OD coil. Vsz series uses like 3/16th and the gsz series use 3/8 copper tubing.

    Ive installed alot of the vsz series...
  25. Replies
    35
    Views
    9,612

    Its a Hyla vacuum. Water filtered. I had one

    Its a Hyla vacuum. Water filtered. I had one
  26. Replies
    10
    Views
    2,870

    I think All HVAC equipment should be banned from...

    I think All HVAC equipment should be banned from Internet Sales
  27. Replies
    14
    Views
    3,799

    Late reply. Why did you add another dryer when...

    Late reply.

    Why did you add another dryer when they already have one installed? Also about txv. It may be superior but Goodman and AHRI show no improvement over fixed.

    Just curious
  28. Replies
    9
    Views
    1,923

    Oregon isn't much better. Those same Cali...

    Oregon isn't much better. Those same Cali dictators are moving here and implementing those same rules for us( not yet, but wont be long)
  29. Replies
    11
    Views
    1,549

    Smaller systems do OK with newer MH homes. Once...

    Smaller systems do OK with newer MH homes. Once you hit 3.5, air comes out is like a tornado. There's a local company (been here for over 100 yrs) sells little old ladies in pre '80 mobile homes, 15...
  30. Replies
    11
    Views
    1,549

    Duct work is the biggest problem, next is the...

    Duct work is the biggest problem, next is the return air. Most newer MH homes, the AH is in the laundry room and most of the time they have 20x20 grills in the Laundry doors. New AH...
  31. Replies
    87
    Views
    12,421

    Caps are code for new installs here in Oregon...

    Caps are code for new installs here in Oregon since 2012. Inspectors are finally starting to enforce them.
  32. Replies
    37
    Views
    23,305

    mitsubishi Mr slim all the way

    mitsubishi Mr slim all the way
  33. Replies
    5
    Views
    1,105

    I have a nit. regulator that only goes to 30 lbs....

    I have a nit. regulator that only goes to 30 lbs. just dial it in for 2 lbs. works for me
  34. Replies
    2
    Views
    842

    Coleman Guys..Need help with coil

    Have a customer that had his OD unit stolen so I need to find out what size (rating) this Indoor coil is. Model number is

    3340A830

    mh
  35. Removing- 2x4 5 ft long Loading- Make the...

    Removing- 2x4 5 ft long

    Loading- Make the supplier store do it on new equip
    improper lifting with the assist of the dolley - change outs
  36. Replies
    1
    Views
    948

    Appoin owners, question for you

    Looking at the operating procedures, it doesn't say anything about purging the lines, of air, before recovering freon. Is there something im missing or just crack a connection?
  37. How much air do you for a 150,000 NG Furnace....Not

    Went to do a bid the other day. This is what I found on a 37 year furnace. Tri level home with main return in bottom bedroom behind the tv, behind tight louvered door, under stair well, through 1/3...
  38. Replies
    102
    Views
    28,213

    Had this one the other day. Worst one I've come...

    Had this one the other day. Worst one I've come across. Goodman Unit

    http://www.use.com/media/2012/0825/2739744/p_001.jpg?1
  39. Replies
    102
    Views
    28,213

    This happened in 2008 in my area. Couldnt find a...

    This happened in 2008 in my area. Couldnt find a cap anywhere.
  40. Replies
    19
    Views
    6,238

    Thats will they're high static systems. Can we...

    Thats will they're high static systems. Can we say Tornado type air flow, LOL Our average temp here in summer is about 98* and 1 to 3 weeks of 110+
  41. Replies
    15
    Views
    5,103

    Nordyne has 14.5

    Nordyne has 14.5
  42. Replies
    19
    Views
    6,238

    The home must be an older model due to only...

    The home must be an older model due to only having a 1 speed fan and the Insulation factor is small. 3 tons (a/c only) seems about right for the area you live in (Michigan) should only struggle on...
  43. Replies
    38
    Views
    11,647

    I just watch some Yellow Jacket videos and they...

    I just watch some Yellow Jacket videos and they use their crt when using their vacuum setup
  44. Replies
    7
    Views
    2,044

    Love It

    Love It
  45. Replies
    74
    Views
    18,964

    Then it has to be with the suppliers we are...

    Then it has to be with the suppliers we are using. Different models I guess. More than likely we'll be doing the mc coils soon enough

    mh
  46. Replies
    74
    Views
    18,964

    Thats weird. All my nordyne Ah has the txv...

    Thats weird. All my nordyne Ah has the txv already installed on the indoor coils. Even the old R-22 ones. THese are all Kelvinator units

    mh
  47. Replies
    74
    Views
    18,964

    The picture I posted is a variable speed AH and...

    The picture I posted is a variable speed AH and rated for a 16 seer system and its a standard tube/fin design with their special coating. It might be different from supplier to supplier.

    MH
  48. Replies
    16
    Views
    4,761

    I just almost had the same problem on a nordyne...

    I just almost had the same problem on a nordyne hp in cooling mode. But.mine would go into suction at compressor. HPS did not trip. indoor Txv went bad.

    mh
  49. Replies
    74
    Views
    18,964

    This is from the new b6 series from nordyne. Its...

    This is from the new b6 series from nordyne. Its not a mc but what the call there ant eater coil. Has special coating to block the corrosive.

    ...
  50. Replies
    54
    Views
    9,225

    AHRI shows the same seer rating for goodman thats...

    AHRI shows the same seer rating for goodman thats using a orfice or txv.
Results 1 to 50 of 365
Page 1 of 8 1 2 3 4