Search:

Type: Posts; User: Chuck

Page 1 of 20 1 2 3 4

Search: Search took 0.16 seconds.

  1. Replies
    7
    Views
    383

    As long as the oil sump is warm! If that is cold...

    As long as the oil sump is warm! If that is cold you have floodback
  2. Replies
    19
    Views
    19,624

    I guess I just replied to a 7 year old post LOL

    I guess I just replied to a 7 year old post LOL
  3. Replies
    19
    Views
    19,624

    This is interesting. I've done a few r22 to 407a...

    This is interesting. I've done a few r22 to 407a conversions and the liquid injection still cycles, couldn't tell much difference, but of course I never timed it before the conversion so it very well...
  4. Thread: REME HALO-LED

    by Chuck
    Replies
    8
    Views
    2,008

    Snake oil.

    Snake oil.
  5. Replies
    4
    Views
    606

    Nice graph. You can see at night when the load is...

    Nice graph. You can see at night when the load is lower the suction pressure is allowed to float higher.
  6. Replies
    11
    Views
    835

    A receiver that size will have a level gauge or...

    A receiver that size will have a level gauge or sight glasses, I don't see the need to calculate it just pump it down and fill it however full you want.
  7. Congratulations! I'm not an owner, but that's...

    Congratulations!

    I'm not an owner, but that's what I look for in an employer, someone who is out there going after new business. Not stuck in a certain familiar rut and refusing to branch out...
  8. Replies
    11
    Views
    835

    I meant plus or minus 2 lbs not that a system...

    I meant plus or minus 2 lbs not that a system holding 25 lbs would have a 2 lb receiver, not sure where that came from.

    My point is that there is really no need to be so exact in charge amounts...
  9. Replies
    11
    Views
    835

    Not in the real world. A pound or 2 in a system...

    Not in the real world. A pound or 2 in a system that holds 25 lbs makes no difference.812218
  10. Replies
    11
    Views
    835

    I just use charts found in this document to get...

    I just use charts found in this document to get pump down capacity of receivers. If the exact size isn't listed you can extrapolate. The density of different refrigerants isn't that much different.
    ...
  11. Replies
    12
    Views
    897

    I'm sorry

    I'm sorry
  12. Thread: Freezer Drain

    by Chuck
    Replies
    25
    Views
    1,316

    https://photos.app.goo.gl/SbagsqS4u6svdvPFA ...

    https://photos.app.goo.gl/SbagsqS4u6svdvPFA

    https://photos.app.goo.gl/SbagsqS4u6svdvPFA
  13. Thread: Freezer Drain

    by Chuck
    Replies
    25
    Views
    1,316

    Get ready for some plugged drain lines, I've had...

    Get ready for some plugged drain lines, I've had several this year. Ripped it out and put it on the outside with copper pipe.

    Running it inside is not allowed in most chain stores, Walmart,...
  14. Thread: Freezer Drain

    by Chuck
    Replies
    25
    Views
    1,316

    I'm OK with it inside if you also up size the...

    I'm OK with it inside if you also up size the drain line. 3/4 drain with a heat tape inside will plug in short order.

    We always use a 6w tape and run it out to the end and back at 4 o'clock and 8...
  15. Replies
    12
    Views
    897

    As to your last question, you want to see around...

    As to your last question, you want to see around 30 to 40 % receiver when everything is working. But don't immediately adjust charge if it isn't! First make sure all controls and valves are operating...
  16. Replies
    12
    Views
    897

    Typically the rack controller is set for a...

    Typically the rack controller is set for a certain suction pressure based on the coldest load. But some are set up to float the suction pressure based on case temps.
  17. Replies
    12
    Views
    1,108

    In auto the beep should quickly settle down to a...

    In auto the beep should quickly settle down to a slow beep. If not call ttt, that's not right.

    Pump speeds up in medium and large leak settings, this is normal
  18. Replies
    23
    Views
    2,199

    Some of us just instinctively know that all. ;)

    Some of us just instinctively know that all. ;)
  19. Replies
    221
    Views
    15,825

    No, haven't had the chance to try 410a.

    No, haven't had the chance to try 410a.
  20. Replies
    221
    Views
    15,825

    Another thing, the stratus compares very well...

    Another thing, the stratus compares very well with the pgm-ir. I used that a lot last winter and my experience was exactly the same as now with the stratus. Maybe a little more consistent and...
  21. Replies
    221
    Views
    15,825

    I wanted to update on this subject after a few...

    I wanted to update on this subject after a few more weeks of using the stratus.

    The H10 is still the king. Especially for those tiny leaks and also for leak checking open air refrigeration cases....
  22. Poll: If you truly believe this, put your money where...

    If you truly believe this, put your money where your mouth is. Sue your lawyer for malpractice.
  23. Poll: That's the car driver's fault?? In what universe?

    That's the car driver's fault?? In what universe?
  24. Poll: No, where is it?

    No, where is it?
  25. Poll: You have made it abundantly clear that these hvac...

    You have made it abundantly clear that these hvac techs know far more about these things than yourself.
  26. Replies
    25
    Views
    1,048

    Get a Pixel already :D

    Get a Pixel already :D
  27. Poll: Wow, unbelievable. Highly entertaining, that's...

    Wow, unbelievable. Highly entertaining, that's for sure.

    Next time this happens Brian and you have a case this thin, get a good lawyer. A really really good lawyer. In fact get the best lawyer in...
  28. NAS is a completely different division of the...

    NAS is a completely different division of the company and has no bearing on this discussion.
  29. Replies
    863
    Views
    18,493

    History shows that the simplest explanation of a...

    History shows that the simplest explanation of a thing is usually closest to the truth.

    Some Muslim extremists flew planes into buildings is what happened.

    You like to compare this to Hitler...
  30. Replies
    863
    Views
    18,493

    So now it's been 7 days. What is supposed to be...

    So now it's been 7 days. What is supposed to be happening?
  31. Replies
    863
    Views
    18,493

    Give us a break.

    Give us a break.
  32. Replies
    17
    Views
    867

    I have a hard time believing that a 9k unit would...

    I have a hard time believing that a 9k unit would not work in a space that small. Unless there are some severe building envelope problems. If that room is built well, and insulated correctly then I...
  33. I know several of the Lennox people in the...

    I know several of the Lennox people in the Wisconsin district. They have been there a long time and seen to be happy. I think it will depend largely what kind of district manager runs your district.
  34. Replies
    863
    Views
    18,493

    It's interesting that some of the same people who...

    It's interesting that some of the same people who pontificate about government incompetence also believe the government pulled off this huge conspiracy and then somehow kept it secret all these...
  35. Replies
    20
    Views
    1,558

    If the same specific unit is going down because...

    If the same specific unit is going down because of oil logging more often than once a year, I would call that a problem. But usually they run for several years after letting them warm up.

    If a...
  36. Replies
    58
    Views
    2,069

    Yes, it seems like I've read that several times...

    Yes, it seems like I've read that several times already lol but the valve is still too far open.
  37. Replies
    58
    Views
    2,069

    That next to last sentence makes no sense to me. ...

    That next to last sentence makes no sense to me.

    You could be right, I expect to see lower than 38 on a freezer that's close to temp but that could be due to the valve being too far open.
  38. Replies
    58
    Views
    2,069

    What gas? I think you need a bigger pump. You...

    What gas?

    I think you need a bigger pump. You have higher suction than you should. The low superheat is a problem but not the problem.
  39. Replies
    4
    Views
    532

    I would always use my 1/8" probe, it's tight and...

    I would always use my 1/8" probe, it's tight and you can't use the handle on the Cooper sensor. Just grab the probe near the handle with pliers and use that to push it in and out.
  40. Replies
    31
    Views
    2,973

    My phone

    My phone
  41. Replies
    221
    Views
    15,825

    Yes, I pulled a fan.

    Yes, I pulled a fan.
  42. Replies
    221
    Views
    15,825

    No, I do not have a YJ bottle.

    No, I do not have a YJ bottle.
  43. Replies
    221
    Views
    15,825

    So I now have a Stratus leak detector that works...

    So I now have a Stratus leak detector that works great, no more erratic readings thanks to instant response from Inficon.

    Checked a store yesterday that has been losing some gas and found a leak...
  44. Replies
    221
    Views
    15,825

    Yes, I spoke to Inficon this morning and the...

    Yes, I spoke to Inficon this morning and the issue is being resolved. Thank you!
  45. Replies
    221
    Views
    15,825

    Your h10 pro is probably no different than a new...

    Your h10 pro is probably no different than a new one. Might need a new sensor.
  46. Replies
    221
    Views
    15,825

    That's interesting. I seldom see 410a but would...

    That's interesting. I seldom see 410a but would that be any different than other 400 series gases? Mostly refrigeration so 407 448 etc.

    The pgm-ir works fine, you have to set the type of gas so...
  47. Replies
    221
    Views
    15,825

    Does yours go nuts just by tipping it? Let me...

    Does yours go nuts just by tipping it?

    Let me know if this video link works.

    https://photos.app.goo.gl/vurPHRKpgGSjr8j58
  48. Replies
    221
    Views
    15,825

    Actually I don't know for sure what kind it is....

    Actually I don't know for sure what kind it is. The original a/c was Amana and I changed it out with a used Lennox. Never did change the 1995 evap. But it had a 2012 goodman furnace
  49. Replies
    221
    Views
    15,825

    I guess I am the aforementioned spoiled rotten...

    I guess I am the aforementioned spoiled rotten coworker.

    Just got the new Stratus and I also have the H10 Pro. Walked around in my house and once in a while the detector would show ppm up to 14...
  50. Replies
    0
    Views
    394

    Smart Pro/R system

    Any refer guys out there using them? I know they've been out for a few years now, how are they holding up?

    One thing they would be nice for is startups, watching multiple evap superheats at once...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4