  1. YES! My problem here with a standard tablet is...

    YES!

    My problem here with a standard tablet is how do you charge it and use the USB connector for the ALC Rnet cable at the same time? Or do I have a fundamental misunderstanding here?

    I guess...
  2. Hmm Android car stereo might fit the bill too....

    Hmm Android car stereo might fit the bill too. Should expect it to meet temp/vibration environmental for mechanical room. Panel mount. Separate power supply from the USB, we would have to find a...
  3. Panel mount android tablet for HMI anyone?

    Looking for a panel mount android tablet, anyone used one before?

    Needs to have
    -play store so we can get the app we need
    -USB OTG (almost all android devices have this)
    -power connector that...
  4. Thread: BAS Anayltics

    by MaxBurn
    Replies
    3
    Views
    755

    Do they integrate via BACnet or pull data out of...

    Do they integrate via BACnet or pull data out of reports?
  5. Replies
    4
    Views
    449

    These are generally two different worlds and...

    These are generally two different worlds and career paths IMO, not really much crossover. Niagara is the only thing that tries to work in both but I've never seen it done due to it being two entirely...
  6. Yes the proxy terminates the SSL session to the...

    Yes the proxy terminates the SSL session to the people on the internet. The content can come from a regular HTTP web page inside the LAN. The SSL certs come from lets encrypt and renew every 90 days...
  7. Replies
    10
    Views
    547

    Need a sheetmetal fab shop. Aluminum with four...

    Need a sheetmetal fab shop. Aluminum with four bends to stand off the back plate and a bunch of holes for the stats is what I'm thinking.
  8. Not a clue, shame on Distech for not having good...

    Not a clue, shame on Distech for not having good docs on that. It's becoming more important as this goes on.

    Outside the box; is there a computer on site that can serve up Nginx or Traefik...
  9. Replies
    4
    Views
    301

    Is there a fan failure alarm point? Use that.

    Is there a fan failure alarm point? Use that.
  10. Replies
    12
    Views
    370

    Data usage wise for our sites we have an always...

    Data usage wise for our sites we have an always on OpenVPN tunnel and inside it is just BACnet for the site. These sites use in the 200-800MB/mo it seems. I think I have a couple big sites that use...
  11. Replies
    12
    Views
    370

    Oh, and site survey wise just skip all the tools...

    Oh, and site survey wise just skip all the tools etc. If your phone on the same carrier gets a decent speed test you should be fine. In general these will get a much stronger signal than your phone...
  12. Replies
    12
    Views
    370

    I am aware of the product but I haven't looked at...

    I am aware of the product but I haven't looked at one.

    Initially I started out working with the cradlepoint IBR200 which is a great product, very reliable and industrial environmental and temp...
  13. Replies
    204
    Views
    19,555

    Doing server moves this weekend. I had one of...

    Doing server moves this weekend. I had one of these connected to an Edgerouter. Pushed new VPN keys to the edgerouter, reboot it and when it came back the backrouter was gone. As in the edgerouter ui...
  14. Replies
    204
    Views
    19,555

    Looks like the current version of that is...

    Looks like the current version of that is COM20019I3V-HT, much smaller than what is pictured above. Found in a current module.
    ...
  15. For the managers; if the computer does not have a...

    For the managers; if the computer does not have a blue or white light anywhere it needs to be replaced. If it is in a beige case and/or it has a CRT or less than 17" 4x3 monitor it needed to be...
  16. Replies
    204
    Views
    19,555

    Lots of changes going on with firmware updates...

    Lots of changes going on with firmware updates recently.

    What is the possibility of adding ARCnet 156k to the BACnet Router?
  17. Replies
    19
    Views
    9,676

    Verify with third party discovery tool like YABE....

    Verify with third party discovery tool like YABE. That will point you at Niagara or lg support.
  18. Replies
    19
    Views
    9,676

    Page 57 SetRoomTemp? ...

    Page 57 SetRoomTemp?

    http://s3.supplyhouse.com/product_files/LG-PQNFB17C1-Install-Instructions.pdf
  19. Replies
    1
    Views
    124

    I don’t think any of that matters, you just need...

    I don’t think any of that matters, you just need a mail server on the internet to reach out to. Unless tossi offers that as a service which would be nice.
  20. Replies
    21
    Views
    546

    Plastic near UV in a year or two sure but I’m...

    Plastic near UV in a year or two sure but I’m having trouble buying weeks of damage. Still thinking EMI damage somehow with the averaging sensor being effectively a big antenna next to the lights....
  21. Replies
    21
    Views
    546

    Does it look cracked faded or falling apart? Even...

    Does it look cracked faded or falling apart? Even if it's some sort of EMI the bapi metal cladding might help. How long was it running before adding UV?
  22. Replies
    21
    Views
    546

    Interesting, seems the belimo averaging sensors...

    Interesting, seems the belimo averaging sensors are a plastic tubing? True? Their data sheet indicates the "housing" is UV resistant.

    The Bapi averaging sensors we use are aluminum tube....
  23. Yup, if it's sort of working best to leave it. If...

    Yup, if it's sort of working best to leave it. If it needs changes or is broke telling the customer "sorry, everyone that knew how to work on that is dead or retired" generally wakes them up enough...
  24. Replies
    18
    Views
    672

    Seems everything is having supply chain issues...

    Seems everything is having supply chain issues now, I was just informed we have something like a thousand ZN551 backordered. The stuff going on like the Dubai, Shenzhen, and Ningbo port situations...
  25. Replies
    3
    Views
    307

    If you need a router you literally can't ask for...

    If you need a router you literally can't ask for more for less with this; http://www.hvacrcontrol.com/bacnet-router/

    What needs to be changed to work with your front end I've no idea though.
  26. Replies
    22
    Views
    906

    And ALC needs to hear that, you tell your RSM was...

    And ALC needs to hear that, you tell your RSM was told about this stuff?
  27. Replies
    22
    Views
    906

    ALC FDD libraries are pretty restrictive IMO....

    ALC FDD libraries are pretty restrictive IMO. First off they require new programs for the bulk of the equipment, which should trigger a recommissioning with such drastic changes. Classic example is...
  28. Replies
    22
    Views
    906

    Based on your profile info it looks like this is...

    Based on your profile info it looks like this is your dealer for authorized service. ALC dealers have territories they aren't really allowed to cross so calling around will probably circle around...
  29. If you are replacing the M0100 with the M4106...

    If you are replacing the M0100 with the M4106 make it the same address as the old module and download it inside WebCTRL. Make sure all the input jumpers are the same and you should be good on that. ...
  30. Replies
    46
    Views
    2,379

    Are there ultrasonic monitors for permanent...

    Are there ultrasonic monitors for permanent installation and triggering alerts?

    edit; found a couple

    https://www.uesystems.com/ontrak-smartlube/
    ...
  31. Replies
    17
    Views
    875

    Looks like we are ready to start looking into...

    Looks like we are ready to start looking into this stuff. Ideally we would like to get it into the front end via hard inputs or bacnet/modbus etc too.

    Monnit has some things now too.
    ...
  32. Automated Logic; End of RMA support for old modules

    Really old ALC modules like the Z, T, R, and G line modules plus the S6104 may no longer be repaired by ALC. These modules are 18 to 25 years old, it was a good run.

    Basically if you have...
  33. Replies
    37
    Views
    13,119

    ALC USB-L or USB-K I think should do it.

    ALC USB-L or USB-K I think should do it.
  34. Replies
    2
    Views
    364

    Some of the GUI HMI panels will also put out a...

    Some of the GUI HMI panels will also put out a web page of what's on the panel too.
  35. Replies
    22
    Views
    906

    The big ones. -keep software up to date...

    The big ones.

    -keep software up to date
    -redo TAB once and a while
    -recommission once and a while
    -backups and off site storage of backups
  36. Replies
    1
    Views
    379

    Many discussions already on here regarding...

    Many discussions already on here regarding backdooring a jace already. AX isn't bad at all. Early N4 seems to be a big problem, they added the reset procedure after several versions, don't know when...
  37. Was the run LED solid and the error 2x a second...

    Was the run LED solid and the error 2x a second when that modstat was taken? I'm now thinking if it were exec startup halted you might not even be able to get a modstat in that state.

    Anyway one...
  38. Damn skippy. Near the top of the modstat you...

    Damn skippy. Near the top of the modstat you didn't show it will probably say something like 1 PRGs initialized. 0 PRGs running. after it locks up.

    Not having an ACTnet actuator attached at all...
  39. The ACTnet controllers are somewhat new so it's...

    The ACTnet controllers are somewhat new so it's important to stay on top of driver updates. I'm showing 6-06-041 is current for the ALC version of the ACTnet zone module, can you check if you have...
  40. Look up relay logic XOR. That will get you...

    Look up relay logic XOR. That will get you started.
  41. Replies
    55
    Views
    3,563

    Same, but we use a pink wire to indicate...

    Same, but we use a pink wire to indicate something that goes down when a safety trips. We come off the strip red and the first smoke or float sensor transitions to pink before it goes to our...
  42. Replies
    55
    Views
    3,563

    Oh, so you took black off the strip and went to...

    Oh, so you took black off the strip and went to the float sensor and came back with the black in the background with the two reds? Which presume go to the stat and outside?

    We handle things a...
  43. Replies
    55
    Views
    3,563

    What's with mixing up the red and black wires? ...

    What's with mixing up the red and black wires?

    Looks really clean though.

    -controls tech
  44. Replies
    204
    Views
    19,555

    By the way, in ALC discovery while the quick list...

    By the way, in ALC discovery while the quick list I shared before in plain text does appear to have a problem displaying names with pipe in them the REAL view you need to work with does not.
    ...
  45. Replies
    204
    Views
    19,555

    That's perfect, thank you!

    That's perfect, thank you!
  46. Replies
    5
    Views
    706

    I'm going to guess you got blocked because what...

    I'm going to guess you got blocked because what was being sent (rate/contents/whatever) triggered a spam filter somewhere. That's going to be VERY hard to troubleshoot and depending on where it's...
  47. Thread: Outages

    by MaxBurn
    Replies
    5
    Views
    1,181

    Like HVAC-talk is getting attacked? Just got...

    Like HVAC-talk is getting attacked?

    Just got this a few seconds ago;

    Database Error Database error
    The database has encountered a problem.
    Please try the following:
    Load the page again by...
  48. Thread: Outages

    by MaxBurn
    Replies
    5
    Views
    1,181

    Outages

    The entire site is up and down this morning and yesterday morning, wondering if this will even post.

    This site canít be reachedhvac-talk.com took too long to respond.

    ERR_CONNECTION_TIMED_OUT
  49. Thread: Barf

    by MaxBurn
    Replies
    23
    Views
    2,529

    dedupe, site issues...

    dedupe, site issues...
  50. Thread: Barf

    by MaxBurn
    Replies
    23
    Views
    2,529

    It doesn't take a genius and a calculator to know...

    It doesn't take a genius and a calculator to know each room needs a return, supplies need to be near outside walls, and the ductwork/grills etc CFM needs to be in the ballpark of the unit CFM. We are...