  1. Is the mini-split unit 2 months old or 5 years...

    Is the mini-split unit 2 months old or 5 years old?

    How long did/does it run
    when it is < 102'F outside?

    < 114'F Forecast : ' Next Week' or so
  2. Replies
    21
    Views
    696

    Post # 7: " ... I have the thermostat set to 80...

    Post # 7: " ... I have the thermostat set to 80 degrees btw. "
  3. Replies
    21
    Views
    696

    AZ AC is UNreasonably Difficult. ...

    AZ AC is UNreasonably Difficult.

    UNReasonable = have to address 4 Complicating Factors insteead on Only 2.
  4. WHAT A/C performance should one expect at highly...

    WHAT A/C performance should one expect at highly elevated outdoor temperatures?

    ATTACHMENT
    ___________

    3-Ton 14 SEER Example


    Load capacity will decrease about 22% from 85'F to...
  5. Replies
    2
    Views
    134

    You are fighting a steep uphill battle with a ...

    You are fighting a steep uphill battle with a Single HOSE portable unit.

    See this DUAL Hose model
    WHYNTER model ARC-122DS

    ...
  6. SHADING OBVIOUSLY makes a Significant Difference ...

    SHADING OBVIOUSLY makes a Significant Difference
    at higher (> 95'F) temperatures.

    The condensing unit perfomacce will
    degrade SIGNIFICANTLY when it is 115'F outside.
    PLUS, the condenser will...
  7. Replies
    21
    Views
    696

    WHEN did you measure the ACTUAL air flow of Your...

    WHEN did you measure the ACTUAL air flow of Your 5-ton system?
    What was the total CFM ? _____

    What is the T.E.S.P. ? > 1.0" ?
    ... --- __ Total External Static Pressure

    If the blower...
  8. Replies
    21
    Views
    696

    A 4-TON, 2-stage Heat Pump may be appropriate. ...

    A 4-TON, 2-stage Heat Pump may be appropriate.
    __ First { Low} Stage would be ~ 70% * 4.0 = 2.8 Tons

    Performance must be derated for 115'F Outside Air.

    Aluminum window frame increases...
  9. Replies
    21
    Views
    696

    How much power does the condensing unit use...

    How much power does the condensing unit use AS-TESTED?
    __ < 4,500 watts ? ?? .. ???

    How much power does the AHU use as-tested?
    _____ AHU - Air Handling Unit
    __ < 800 Watts
    Total...
  10. Replies
    1
    Views
    172

    www.mysimplifiedhvac.com __ page 5 My gmail...

    www.mysimplifiedhvac.com
    __ page 5
    My gmail address: racingdan11

    So you will have a Common-Sense, Experienced, Reliable Partner where
    You can concentrate on
    installations,...
  11. Replies
    21
    Views
    696

    House built 19 _ _ ? _______________ 50 Years...

    House built 19 _ _ ?
    _______________ 50 Years old or 90 ?

    Review of Monthly electric bills for each of last 12 or 24 months
    would indicate how much of the total is used for A/C.
    _ ... __ 36%...
  12. The Return duct will be a Negative Pressure.

    The Return duct will be a Negative Pressure.
  13. MSDS KILZ Original ...

    MSDS

    KILZ Original

    https://www.kilz.com/binaries/content/assets/kilz/pdf/msds/1009-kilz-original-int-ext-low-voc-sds.pdf
    ...
  14. I do not see how a dehumidifier will be effective...

    I do not see how a dehumidifier will be effective in a low humidity area.
    ASHRAE Climatic Conditions
    Dew Point _ 61.1'F
    HR _ _____ 80.6 _______ Humidity Ratio
    MCDB ___ 68.1'F _____ Mean...
  15. Note that the HVAC Design Process diagram ...

    Note that the HVAC Design Process diagram
    Starts with
    __ CONSTRUCTION DETAILS __

    1. WINDOWS
    _ Orientation __ #
    __ North ___ __
    __ South ___ __

    ___ East ___ __
  16. Alternate: TWO 2-Ton Heat Pump Systems ...

    Alternate: TWO 2-Ton Heat Pump Systems
    __________________ Eliminate the temperature difference between the floors

    _______________________ ??? ???
    ____________ $ 0._ _ _ / kw-hour
    ...
  17. Where is this resdience located ? ___ Country...

    Where is this resdience located ?
    ___ Country _______
    _____ State _______
    _________ ZIP _ _ _ _ _
  18. Where is the orginal Duct Design Drawing?

    Where is the orginal Duct Design Drawing?
  19. Replies
    13
    Views
    328

    If a house needs ~ 2.8-Tons, what is the actual...

    If a house needs ~ 2.8-Tons,
    what is the actual CFM & dT performance
    required for an installed 3.0 Ton System to maintain 75'F?

    ________ Example ___
    With dT of 15'F, the actual capacity...
  20. Replies
    3
    Views
    220

    approximately 30'x30' with 10' ceilings. The...

    approximately 30'x30' with 10' ceilings.

    The shop will soon be insulated

    WHERE in New York?
    _______ Syracuse, ....
    _________ Design Temperature: ~ 4'F

    _ Floor Area: 900 Sq Feet
    ...
  21. Based on the narrative above, it appears that the...

    Based on the narrative above, it appears that the duct work installation was Not completed.

    Compare all the photos of the As-Built duct work with the Duct Design Drawing.

    Perform a MANUAL D...
  22. 39,800 BTU/HR COOLING at 94'F 72,330 BTU/HR...

    39,800 BTU/HR COOLING at 94'F
    72,330 BTU/HR HEATING at 9'F

    Where do the Construction Details differ from the plans and This Model ?

    Given the past 12+ months Energy costs and Use,
    This...
  23. Replies
    33
    Views
    848

    I do not see any difference in the rated air flow...

    I do not see any difference in the rated air flow rates.

    https://www.amana-hac.com/products/gas-furnaces/90-afue-gas-furnaces/96-afue-amvc96

    Air flow using a 5-Ton A/C will ALWAYS be suspect...
  24. Replies
    10
    Views
    328

    What was the Total Air Flow rate stated in the...

    What was the Total Air Flow rate stated in the original Commissioning Report?

    What is the T.E.S.P. ?
    ___ Total External Static Pressure

    Furnace Model # ________
    ___ Coil Model #...
  25. Replies
    18
    Views
    387

    1991 Built 2,000 Sq Ft __ 2- Story __ RI ...

    1991 Built
    2,000 Sq Ft __ 2- Story __ RI

    24,090 BTU/HR at 88'F

    20,520 BTU/HR at 88'F __ SENSIBLE Cooling Load

    IS this Sample Calc close to your CONSTRUCTION DETAILS ?
  26. Approximate SDGE Energy Cost

    Approximate SDGE Energy Cost
  27. 2- Tons at 88'F Design Temperature Pre-cool...

    2- Tons at 88'F Design Temperature

    Pre-cool and
    Let indoor temperature rise ~ 3'F to 78'F in late afternoon
    IF on SDGE Time-of-Use Rate.
    ___ Peak Rate : 4 pm to 9 pm

    Replace the...
  28. Replies
    18
    Views
    387

    Follow the HVAC Design Process ...

    Follow the HVAC Design Process
    ______________________ Figure 3

    Each residence is Unique.
    __ Age
    __ Size / # of Floors
    __ Location
    __ Glass Area
    __ Infiltration
  29. Replies
    3
    Views
    310

    You might be OK, but the DX systems will not be...

    You might be OK, but the DX systems will not be able to
    operate at the low Supply Air temperature to obtain 69'F / 45% room conditions.
    72'F at 54% R.H. might be a realistic expectation.

    I...
  30. Replies
    3
    Views
    310

    INSIDE CONDITIONS as Specified by Owner : 69'F...

    INSIDE CONDITIONS as Specified by Owner :
    69'F at 45%
    Dew Point: 46.8'F

    How does one provide the cold supply air to accomodate this request?
    Supply Air must be ~ 40'F

    It would be a...
  31. Replies
    3
    Views
    400

    Recent local weather IS or EXCEEDS ASHRAE Design...

    Recent local weather IS or EXCEEDS ASHRAE Design Conditions.

    200 to 300 hours per month for ~ 3 months would be Normal operating times IMO
    _ 7 to 10 hours / day ___

    Obviously, if the...
  32. Seems rather difficult IMO However, anything...

    Seems rather difficult IMO
    However, anything is Do-Able.

    Outside conditions are in the Attachment.

    How much infiltration in this warehouse
    that basically sits in the middle of the...
  33. Replies
    10
    Views
    591

    Damn, Good Luck with THAT. The possibility...

    Damn, Good Luck with THAT.
    The possibility of success ... Negative 100%

    The possibility of additional damage : Very HIGH
  34. ASHRAE 62.2 various editions 0.01 * Floor...

    ASHRAE 62.2 various editions
    0.01 * Floor Area + 7.5 ( # Bedrooms + 1)

    Minimum run time 3 fans at about 104 CFM each :
    ~ 12 minutes per hour

    or one fan ~ 40 Minutes / Hour
  35. Replies
    2
    Views
    231

    At 500 CFM /Ton, I wonder how ' Upstairs ... now...

    At 500 CFM /Ton, I wonder how ' Upstairs ... now cools great'.

    How is the Temperature Rise on the Upstairs 120,000 BTU/HR York unit
    with ~ 1,000 CFM?
  36. Guess on the bldg size / construction for an...

    Guess on the bldg size / construction
    for an INITIAL Load Estimate

    __
    EXAMPLE
    __ 91'F ODT / 64'F Interior

    ... ... ATTACHMENT
    _______ 45,800 BTU/HR Cooling +/- 30%
    _______ ...
  37. Replies
    5
    Views
    329

    Is your neighbors house < 14' of the proposed...

    Is your neighbors house < 14' of the proposed condensing unit relocation site?
  38. CONSTRUCTION DETAILS STARTS With: 1. Glass...

    CONSTRUCTION DETAILS

    STARTS With:
    1. Glass
    a. Area & Orientaton
    b. Type : Single, Double or Triple Pane
    c. Tinted or Clear

    2. Square Feet / Floor
    _ Basement : _ 800 SF
  39. Go through each step of the Process

    Stick to the guidelines
    ________ Figure 3 __ RESIDENTIAL HVAC DESIGN PROCESS
    ... WWW.MYSIMPLIFIEDHVAC.COM
    gmail address: racingdan11

    STEP 1 _ CONSTRUCTION DETAILS

    CRITERIA:
    ...
  40. Direct ordering of parts frequently results in NO...

    Direct ordering of parts frequently results in NO Warranty.
    Could be a rather poor position to be in ~ 4 to 8 years after installation.

    Follow Figure 3 _

    Year Built _ _ _ _

    Number,...
  41. Replies
    8
    Views
    487

    Are you combining the supply ducts also? If...

    Are you combining the supply ducts also?
    If YES, What size?
  42. Replies
    8
    Views
    487

    Just when one starts to think that they have ...

    Just when one starts to think that they have Heard Everything ... ...

    This situation should turn out to be 1 for the Price of Two.
    _____________ or more likely Price of FOUR after ~ 2 years...
  43. To provide 65'F at 45% Relative Humidity, the...

    To provide 65'F at 45% Relative Humidity, the cooling coil must
    have an Apparatus Dew Point ADP of ~40'F.

    Chilled Water at 36'F can provide a ~ 42'F Leaving Air Temperature
    IF the...
  44. Replies
    7
    Views
    425

    Problem Definition ?..??

    What's the question now?

    Can any1 make sense
    from non-sense / ill-defined issue ?

    Size :_ Post photos of the equipmemt nameplates.
  45. Replies
    9
    Views
    347

    YOUR EQUIPMENT SELECTION needs to be performed ...

    YOUR EQUIPMENT SELECTION needs to be performed
    prior to Request for Proposals [ RFP / RFQ ] so all bids are
    for CLOSE-TO-EQUAL Systems.

    THEN
    Formallized, Systematic
    CONTRACTOR BID/...
  46. The procedures to follow are: ... RESIDENTIAL...

    The procedures to follow are: ...
    RESIDENTIAL HVAC DESIGN PROCESS
    ... __ Figure 3

    THEN you are Ready with provided SPECS to request specific proposals
    to meet your requirements.
  47. .. BRYANT .. ... ... :whistle:

    .. BRYANT ..
    ... ... :whistle:
  48. Replies
    1
    Views
    235

    INFINITE Wisdom is self-Bestowed by OwnerS

    INFINITE Wisdom is self-Bestowed by OwnerS
  49. No specific information provided to enable one ...

    No specific information provided to enable one
    to make an appropriate selection.

    Manual J needs to be performed to
    determined the requried Q. Sensible Load.

    GENERIC EXAMPLE
    of what a...
  50. Replies
    10
    Views
    702

    MERV 8 is adequate. ____ Use a 3", 4" or 5"...

    MERV 8 is adequate.
    ____ Use a 3", 4" or 5" thick filter.

    Higher E.S.P. will create a hotter blower motor with an associated reduced life.