Search:

Type: Posts; User: QualityAssure

Page 1 of 5 1 2 3 4

Search: Search took 0.02 seconds.

  1. Anyone Buying New Windows for Their Home ?

    DAM - can't seem to Find Very Good Windows . .

    Not even Required - Dade County Code , Which most can't even do . or claim to Not Know what those Spec's are .. LOL


    So after asking &...
  2. Replies
    24
    Views
    1,148

    Last Time I Bough a Car - there was No CD - DVD ...

    Last Time I Bough a Car - there was No CD - DVD , Sound Quality is Far Superior on those then some memory stick ..

    Most 9090DB Owners will Rip New one on Sound Quality . .

    , Yes they take...
  3. As Unit gets Hot - so does the capacitor ~...

    As Unit gets Hot - so does the capacitor ~ Probably even more so . . I had 3 HVAC Guys check a Capactior I Took Off My system
    All 3 Told Me as - They Checked it with Their Meters - It was Good !...
  4. I Believe U need to Tell system ( Stat ) How many...

    I Believe U need to Tell system ( Stat ) How many Zones - First . .
  5. Replies
    24
    Views
    1,148

    Yes the Old Electronics were Built Like Brick ...

    Yes the Old Electronics were Built Like Brick Poop House . . :angel:

    Here's One I Picked up over in Japan @ Military BX for $295.oo HELLO

    5 Years Later when Announced Going to Stop...
  6. LOL, I have worked with many Engineering Forms...

    LOL, I have worked with many Engineering Forms over the Years & Ingersoll Rand - Drives Me Nuts with Their RPN - Reverse Polish Notation -

    Many Setting at Not available - 1 Unless Clock is...
  7. Replies
    23
    Views
    861

    I'm on Statin for about 12 months Now - Doc...

    I'm on Statin for about 12 months Now - Doc wanted Me to Up Dosage at First 40 Days in I Tried it and with 24 Hrs. had gotten Stabbing Muscle Pain doing everyday Normal Activity ..

    Instead I Cut...
  8. Replies
    23
    Views
    1,116

    OLD GUY's - Cap

    OLD GUY :
    Speaking of Caps , I just did 1 on 4 Ton Trane - 2 stage

    Old one was 2.5 Inch Dia . / New Titan Pro 2.0 Dia - Titan was also .22 less in Volume & 1/2 Oz Lighter

    I could swear...
  9. Replies
    23
    Views
    1,116

    LOL , Haa looks like they wanted to Squeeze that...

    LOL , Haa looks like they wanted to Squeeze that Puppy in Tight Spot - so Smacked with Hammer - That will be " Great for Precision Spacing "
  10. I Actually had to Remove of of these Heater from...

    I Actually had to Remove of of these Heater from few Homes in Florida ~ Maybe they were good Idea 25 years ago ..
    Not in Florida

    Great Idea in NC , SC , GA
    TN, VA , TX , etc CA . .
    ...
  11. A Vapor Retarder it is for Sure , also Now there...

    A Vapor Retarder it is for Sure , also Now there are 15-20 Different Breathing - Wicking - Exterior Wall Mats that may be applied to Block Before all Finish Walling Materials Go On ..

    Wow in...
  12. Wow Really Cool Stuff - No Pun intended . . If...

    Wow Really Cool Stuff - No Pun intended . .
    If I had only Know this Field was an Inventor's Play Box - I would have Majored in Refrigeration . .

    Anyhow I do Understand what He's Implying ,...
  13. Replies
    51
    Views
    7,932

    A Basement has a Floor like Concrete or Tile...

    A Basement has a Floor like Concrete or Tile something , a Cellar has generally Dirt Floor .. just saying Builder's Knowledge ..

    Next Time some Lady say My Husbands a Lawyer , She's Upset then...
  14. I'm with Ya - Took it out and Using Fallen Trees...

    I'm with Ya - Took it out and Using Fallen Trees from Storms with Insert for Extra Heat Only during Cold Snaps or Storms ( Back Up )
  15. OK, Good to Know . . so 60% of 47000 = 28200 but...

    OK, Good to Know . . so 60% of 47000 = 28200 but that won't do much or Run for very Long with No Outside Compressor Fan Running . .

    Unless Fan is Running on Compressor ? 100%
  16. Replies
    60
    Views
    7,284

    Haaa , WHAT ?

    By Box of N95's ~ all have NO Valve they Filter both Directions ..

    Best Look to see If You bought Fakes .. :oops:
  17. Move to Alaska

    Move to Alaska
  18. Got No Cookies , Have a VPN , Will Be Smiling @ End

    Thinking of Buying 2 Stage , 4 Ton , is there a way to see whether it's a ~ 50/100 or 70/100 ~ Possibly 850 Stat , but really today all "Smart Stats"
    Probably are 100% OK . .


    If 4 Ton is...
  19. Replies
    4
    Views
    608

    What You - Guys Think this a Good Buy - as it...

    What You - Guys Think this a Good Buy - as it also has Full Assembly - Not just a Grill Door . .

    Don't see Price List for Comparison with the Truair 290 grill . .
    ...
  20. Yes, I do Type with too many Caps , sorry .. Old...

    Yes, I do Type with too many Caps , sorry .. Old Habit from writing Tech Instructions . .

    Some Good Points from Experience Tradesmen - Thank You

    I may have been Overly Pissed Off - 4 yrs....
  21. Replies
    4
    Views
    608

    I Found this One - is this one of those Truaire...

    I Found this One - is this one of those Truaire 290 ~ Full Assemblies ~
    https://www.ebay.com/itm/333695583303
  22. Yes, Most of the Gas Units - for 500 Miles are...

    Yes, Most of the Gas Units - for 500 Miles are Non-Vented . . I have Installed 1 Vented Unit and that was much Better and Dryer ..
    I should have been more Descriptive about the Wet Heat .. ...
  23. OK, just Add some Help , Wife's Dad has Property...

    OK, just Add some Help , Wife's Dad has Property in Florida with Two Wells and Both will do Stains Your Talking about , only one has better water . Yet the Near by Their Well is only 24 ft Farther...
  24. This much better Example of Well be done...

    This much better Example of Well be done Correctly - DIY with - Pump & Water . .
    https://youtu.be/fE4QSUXS-j4
  25. Wonder How many Have ~ Removed Electric or Gas Unts . . ?

    How many Have - Taken Out Gas Logs - replaced with a Real Insert to Burn Wood ?

    Before You say it Yes those are Bit more work . . But I for One - Enjoy the Crackle Pop of Real Fire .

    Mostly...
  26. Replies
    4
    Views
    608

    Tried to Find 100% All ~ Alloy

    A Complete Framed Assembly ~ Return with Grill Filter Door ~ 100% Aluminum . Swing Open ..

    I Only able to find 1 small Grill Only , Many Other's Claimed to be Aluminum but in Fact Powder...
  27. Nice stuff about the Tanks - are those Stainless...

    Nice stuff about the Tanks - are those Stainless Steel Tanks , or Lined ?
    Also the Water Temps You Mentioned from Shallow Source , what are they in Winter ?

    DIY - Wells are Very Easy in Florida ~...
  28. Thread: Boom !

    by QualityAssure
    Replies
    31
    Views
    6,330

    U Mentioned a Chimney Box , NOT a Full Masonary...

    U Mentioned a Chimney Box , NOT a Full Masonary Chimney . . Correct ?

    If that's So I have seen those Guys place a Lot of Straps - could be Pipe Moving inside ( Sliding ) Strap - over Locking...
  29. Even in TN Top 6ft of Earth gets pretty Warm in...

    Even in TN Top 6ft of Earth gets pretty Warm in 2nd Half of Hot Summer . . , Unless You have a Full 9-10ft Deep Basement - Completely Buried -
    Then with some Top Layers after Cap stone - which will...
  30. Your Temps are too High , so Your Needing to Pump...

    Your Temps are too High , so Your Needing to Pump a lot more . . I Offen have Heard Submersible Pumps Run ~ WAY ~ Cooler ..
    Is that also Effecting Temps ? ( Don't Know Where Temps Readings were...
  31. Replies
    48
    Views
    2,795

    It's Most Likely Your Building - the Mass of Heat...

    It's Most Likely Your Building - the Mass of Heat in the Attic or Roof system & Outside Sunny Brick Walls have reached Critical Load and Pumping massive
    Amounts ~ of ~ BTU's - straight into Your...
  32. Very Interesting as I thought the Installations...

    Very Interesting as I thought the Installations in Florida would much Cheater for Geothermal compared to Rest of Country even New install as
    One is able to do Well with a Garden Hose & Pump & PVC ...
  33. I'd Use a Closed Loop , Not an Open Loop - fill...

    I'd Use a Closed Loop , Not an Open Loop - fill the Brick Well with Water from other well Only During Hot Spells , or run it just enough to maintain Higher Level in that
    36 ft deep well ( Only...
  34. Thread: microns

    by QualityAssure
    Replies
    26
    Views
    35,083

    Thanks PHM , looks like a 3 Zone & Head Units...

    Thanks PHM , looks like a 3 Zone & Head Units are going to be PITA , Just got new 2 stage Pump is rated for 25 Micron's , so I was looking
    around @ Micron's ~ looking at Vac Pulls to see effect...
  35. Thread: microns

    by QualityAssure
    Replies
    26
    Views
    35,083

    I'd Pull to 200 Micron's - Hold for 1/2 Hour ,...

    I'd Pull to 200 Micron's - Hold for 1/2 Hour , Pressure it to 250 PSI Nitro
    Pull again to 100 Micron's Hold for 1hr , Pressure Pressure it to 300-350 Psi
    Pull again to 50 Microns Hold for 3 Hrs....
  36. Freaking Hot today - Up in an Attic and the Fan...

    Freaking Hot today - Up in an Attic and the Fan Vent - was Broken - Not Working - so it's like Fix that or Die up here . .
    Thinking - all Attic Jobs should be - NASCAR Water Cooled Vest . .
  37. So True - Hold Downs are from the Other side of...

    So True - Hold Downs are from the Other side of the Tracks - Miami Sum Lord - Rental - Certainly those Exposed Lightweight pc. - Easily Cut - Yeah Rust City !
    Nice Ionic Reaction - should shave 6...
  38. Anything Wrong with this A/C Install ?

    This Area must be Florida , Texas , SC , NC , GA ?

    Looking at the Application of Wind Hold Downs - Cough , Cough . . . anything wrong with this ?
    ...
  39. Replies
    105
    Views
    73,992

    Just to Add - Germany & Euro Based Manufacturing...

    Just to Add - Germany & Euro Based Manufacturing - even If they Pull their Factory's over Here - Usually have all these Cut-Away Views . .
    Inside Internal Coatings Spec's and Details , Details ,...
  40. Replies
    105
    Views
    73,992

    Nice to Here - a Unit that Actually has Sensors - YEAH !

    I'm Especially Interested in the No Humidifier Set Up . .( When You Say Wired As 2 Speed ) Your Tricking the AC - Unit into 2 Stage for Zones ( Really Better Air Control ) Do I Have that Right -...
  41. Why so Far away from Each Other I seen them -...

    Why so Far away from Each Other I seen them - side by Side to take Advantage of Heat Transfer _ Just have to Place Exhaust 3 ft Higher or Lower
    Then the Intake Stack - that said - 90 Degree Elbow...
  42. Trying New Items : Any Of these Tested ?

    Bending a Line High Up on Ladder and Going though Wall - Faster - Might Be ? Anyone Test or Try these out . . ?

    https://www.marketair.com/shop/easybend/easybend-detail.html


    Tested or...
  43. OK - so there are Additional Settings that will...

    OK - so there are Additional Settings that will Allow 20 Min on Stage 1 for Cool Mornings & The System just Picks up the Local Gas & Liquid Temp , Monitors that
    Kick Stage 2 on at Proper Time : ...
  44. OK - Comfort Control - Model TCONT624AS42DA ...

    OK - Comfort Control - Model TCONT624AS42DA

    Thank You for any Paths to follow ..
  45. Max Run Time 5 Min. - Hence I Mentioned Up...

    Max Run Time 5 Min. - Hence I Mentioned Up above First Post , does this External Compressor Unit ( 2 Stage ) Need One of Those Fancy Heat Sinks like the Link :
    to the Fan Less - Liquid Less...
  46. Dan the Mechanical Man : Not sure what Your Set...

    Dan the Mechanical Man : Not sure what Your Set Up is for this Equipment , but I have Similar LOL 2-Stage Trane & Stage 1 _ Pretty Much does Nothing . . . (( All it does is like Pre_Chill...
  47. Designer Dan - Good to Hear , so You have a 2...

    Designer Dan - Good to Hear , so You have a 2 Stage - with 2 Compressors ? Which Model


    Design Logic - GA - HVAC - Good to Hear just seems every % Point that Engineers are able to Squeeze Out -...
  48. Replies
    23
    Views
    16,558

    I had Investigator come out to check over the...

    I had Investigator come out to check over the Unit that got Burnt By Power Surge ( Fried )
    He said He got paid by all His Insurance Company's as an Appraiser . . Drove one of those small Ford work...
  49. 2 Stage Units : Seems These Smart Units - might be Used Smarter . . `\ : - )

    This may have been Mentioned : OK on this Cool Mornings 62 Degrees , Home might be 77 inside - 15 Degree Difference - there is Usually very Heavy Dew - then the Wind Picks Up 8 MPH

    Sure seems 5...
  50. Yes, some Nice Installs over there - don't see...

    Yes, some Nice Installs over there - don't see any second Story with Outside Protection Covers & Long 90's
    How's Drilling through Hard Brick at 10 Degrees or so ?
Results 1 to 50 of 224
Page 1 of 5 1 2 3 4