  1. Replies
    36
    Views
    1,069

    Anyway, it was some kind of wax-looking stuff in...

    Anyway, it was some kind of wax-looking stuff in strainers. Cleaned them with solvent, and reinstalled them. After I triple evacuated it again it was close to 11 pounds over charged. 10.9.( Good call...
  2. Replies
    36
    Views
    1,069

    there was no temperature drop across the drier.

    there was no temperature drop across the drier.
  3. Replies
    36
    Views
    1,069

    I was going by what Russel said should be startup...

    I was going by what Russel said should be startup charge. I found it odd also they would add a flood charge on top of a 90% receiver charge but that is what they wanted to be added. Maybe the 90% was...
  4. Replies
    36
    Views
    1,069

    not 3* across the drier, 3*F temp drop-in liquid ...

    not 3* across the drier, 3*F temp drop-in liquid line temp from end of drier to last evap TXV inlet.
  5. Replies
    36
    Views
    1,069

    The original question was what is your opinion on...

    The original question was what is your opinion on the TXVs going out at the same time? Just found it weird that after it losing its charge and cond fan motor going out I have never seen 3 TXVs start...
  6. Replies
    36
    Views
    1,069

    dang thing repeated my same post and I do not...

    dang thing repeated my same post and I do not know how to delete, not trying to be a smarta$$
  7. Replies
    36
    Views
    1,069

    I am 54 years old , last thing I am in is a hurry...

    I am 54 years old , last thing I am in is a hurry lol.

    I did add the charge up ,
    for 35' of 1/2" line= 2.5 lbs
    90% receiver=28 lbs
    flooded charge =16 lbs
    each evap =3 lbsx3=9 lbs

    2.5...
  8. Replies
    36
    Views
    1,069

    No, I did not avoid it, sorry about that. A...

    No, I did not avoid it, sorry about that. A dirty evaporator would cause reduced SH not excessive, the evaps are clean. The increased compression ratio says it may have a dirty condenser and I...
  9. Replies
    36
    Views
    1,069

    the one thing I am afraid of is overcharge. If I...

    the one thing I am afraid of is overcharge. If I pump it down will it hurt anything if overcharged or will it just not pump down all the way? Headed out in about 45 minutes , we will see , lol.
  10. Replies
    36
    Views
    1,069

    I am not sure about the filter drier but I am...

    I am not sure about the filter drier but I am thinking it somehow made it to the TXVs because of the superheat. Wouldnt the sight glass be flashing if it were the filter drier?
  11. Replies
    36
    Views
    1,069

    I dont know where its at, I am sure it is up...

    I dont know where its at, I am sure it is up above the cooler.
  12. Replies
    36
    Views
    1,069

    I think that's because the 1st coil is frosted...

    I think that's because the 1st coil is frosted over and not collecting any/as much heat.
  13. Replies
    36
    Views
    1,069

    I may have to try that! But with all 3 doing it ,...

    I may have to try that! But with all 3 doing it , I think it was something that contaminated.
  14. Replies
    36
    Views
    1,069

    I am lost what you mean about the liquid line I...

    I am lost what you mean about the liquid line I put a pressure probe at the tailpipe that is perpendicular to the tailpipe manifold outside of evap housing and clamp inside evap housing at the end of...
  15. Replies
    36
    Views
    1,069

    Sight glass is right after the filter drier. it...

    Sight glass is right after the filter drier. it was clear a long time before the pressure came up and stayed clear, I found that really odd. I never thought of checking the drier. It had a high...
  16. Replies
    36
    Views
    1,069

    Guess I am going to pull it down in the morning...

    Guess I am going to pull it down in the morning and check the TXVs for dirty strainers. They are old ALCO AFAE1HC, anyone know if they have strainers?
  17. Replies
    36
    Views
    1,069

    Russel unit 20 years old Need opinion.

    I get a call Sunday night on the beer/drink cooler at 45*F and it's been kept at 35* for those 20 years it's been running until today.
    I get there and the condenser fan is out and unit off on high...
  18. Replies
    26
    Views
    2,365

    I bought the SC480 for the same reason the only...

    I bought the SC480 for the same reason the only complaint I can find with it is the thermocouple does not go all the way into the meter and very hard to get into the meter what little it does. Do you...
  19. Replies
    7
    Views
    636

    The weird thing is this, both breakers had a 9v...

    The weird thing is this, both breakers had a 9v drop across them but when I repaired the wiring and turned the furnace breakers back on ( before doing voltage drop) all elements were working with the...
  20. Replies
    7
    Views
    636

    It was a 15KW furnace and you would be correct, I...

    It was a 15KW furnace and you would be correct, I had to also replace a limit on one of the elements, Great catch Snapperhead! The elements were reading way low amps , like almost 16 a piece and all...
  21. Replies
    7
    Views
    636

    Amp draws were low on the elements, why I decided...

    Amp draws were low on the elements, why I decided to do a voltage drop because, well you know, when voltage is constant and resistance goes up, well that means amp draws go down!. After I replaced...
  22. Replies
    7
    Views
    636

    voltage drop

    Came upon a mobile home furnace that had burned wiring at the element spades and one on a sequencer. The tenant said he has to keep resetting the unit by shutting it off at the thermostat and than...
  23. Replies
    26
    Views
    2,365

    Redfish is a Jim Bergman meter isnt it?

    Redfish is a Jim Bergman meter isnt it?
  24. Replies
    26
    Views
    2,365

    THANKS FOR THAT TIDBIT!

    THANKS FOR THAT TIDBIT!
  25. Replies
    26
    Views
    2,365

    I think I remember hearing a co-inventor of Fluke...

    I think I remember hearing a co-inventor of Fluke is the inventor of Fieldpiece. Anyone else hear that back in the day when FP first came out?
  26. Replies
    20
    Views
    1,860

    I bought the fieldpiece at a good price so I will...

    I bought the fieldpiece at a good price so I will be trying them out today. Should be receiving the temp clamps soon, I believe what I will like them for are critically charged units like ice...
  27. Replies
    20
    Views
    1,860

    Yellow jacket makes test probes?

    Yellow jacket makes test probes?
  28. Replies
    36
    Views
    3,340

    My apologies , this thread brought on flashbacks.

    My apologies , this thread brought on flashbacks.
  29. ?

    ?
  30. Replies
    20
    Views
    1,860

    I was told they work on bluetooth not internet

    I was told they work on bluetooth not internet
  31. Replies
    20
    Views
    1,860

    Everything associated with all software is...

    Everything associated with all software is data-driven, that is the only way to improve on it. So even if they were not interested in who you are sleeping with (FaceBook)they are definitely...
  32. Replies
    26
    Views
    2,365

    I think the 440 is just as good as the swivel...

    I think the 440 is just as good as the swivel 600s with wireless. Those two things do not interest me for the price or size.
  33. Replies
    11
    Views
    1,571

    What do you utilize the heat sensor for in resi...

    What do you utilize the heat sensor for in resi units?
  34. Replies
    36
    Views
    3,340

    after rinsing and repeating , throw the damn...

    after rinsing and repeating , throw the damn thing in the trash and go buy a new fan blade because you now have a piece of $hit and you wasted two damn hours .
  35. Replies
    4
    Views
    875

    Of course I would find this thread the same day I...

    Of course I would find this thread the same day I spent 28 dollars on one...
  36. Replies
    21
    Views
    3,149

    Ya I would not have remembered my old nic if not...

    Ya I would not have remembered my old nic if not for this thread, I searched my name and in this thread, I gave it under the old nic. They asked me if I wanted this nic or the old one, I went with my...
  37. Replies
    21
    Views
    3,149

    you are definetly one of the oldies here , haha....

    you are definetly one of the oldies here , haha. I was working in St Louis back in 04
  38. Replies
    21
    Views
    3,149

    Love rereading old threads. My old nic was...

    Love rereading old threads. My old nic was Wannamakeice. Got offline for awhile and now back. Any of the oldies on this thread still here?
  39. Replies
    3
    Views
    1,037

    Sounds to me you have a better combustion now...

    Sounds to me you have a better combustion now than you did.
  40. Replies
    75
    Views
    2,749

    Loose women are no joke , if not for them I would...

    Loose women are no joke , if not for them I would still be a virgin!
  41. Replies
    75
    Views
    2,749

    Thanks VTP99

    Thanks VTP99
  42. Replies
    75
    Views
    2,749

    How would dropping the amp draw approx 19 amps...

    How would dropping the amp draw approx 19 amps going to help?
  43. Replies
    75
    Views
    2,749

    Oh gotcha, I missed where someone said the lugs...

    Oh gotcha, I missed where someone said the lugs were loose. I need more time in my day to read these long ones thoroughly lol
  44. Replies
    1
    Views
    952

    https://hvac-talk.com/vbb/showthread.php?2226016-K...

    https://hvac-talk.com/vbb/showthread.php?2226016-KM-Hoshizaki-1300SAH
  45. Replies
    75
    Views
    2,749

    Just not sure why they would need to replace the...

    Just not sure why they would need to replace the socket when the issue is after that.
  46. Replies
    75
    Views
    2,749

    Exactly , but you dont have to replace the whole...

    Exactly , but you dont have to replace the whole meter socket , I think replacing the service breaker would be fine if all it is drawing there is 155.
  47. Replies
    75
    Views
    2,749

    155 Amps tripping a 200 Amp service and sparky...

    155 Amps tripping a 200 Amp service and sparky says everything is fine points me to believe you have a weak breaker. Not sure what all the house is running to get that many amps but the breaker...
  48. Replies
    16
    Views
    1,136

    Hoshi for sure. Love that stainless steel evap...

    Hoshi for sure. Love that stainless steel evap and the control of harvest and purge times.
  49. Replies
    1
    Views
    952

    Limed up KM 1300 SAH Hoshizaki

    moved to ice and cant delete
  50. Replies
    5
    Views
    451

    Your name is appropriately applied here , haha

    Your name is appropriately applied here , haha