Search:
Type: Posts; User: markmast
Search:
Search took 0.02 seconds.
-
Ya if i cut the hole open more i should be able to, i havent been back yet
-
Wow, i haven't had that many problems with them, but i did have a callback on ignitors failing which there was a recall on and the tech support said they had a problem with these seals but they...
-
Thank you for the input, appreciate it,
It is going off on limit because the duct work is restricted, i am not sure how the old one worked but the return is just a box in the crawl with 2 - 6"...
-
I've honestly never seen it before and i have been in the trade for 15 years, is it just communicating stats that do this?
-
Also I did check for CO and did not get any reading inside the house or the plenum, which i was worried about if the secondary seal was leaking, but i think it still could be leaking water without...
-
New Continental (Napolean/wolf steel) 96% 2 stage furnace leaking water, installed last winter, had problem with water leaking after install, tech went and changed collector box and gaskets, it was...
-
Just had installers install new 96% 2 stage carrier downflow with new AC and edge thermostat. Customer called few days later because of no heat, found it going off on limit, gas pressure wasn't...
-
Do you do the same thing?
And yes he has more call backs then i think is normal, they come in spurts
-
I agree with you 100% and do the exact same thing except i usually just have my manometer in my hand cause i dont like going in and out.... but the whole point is the first thing on your list is a...
-
Lol i dont think hes going through fuses, i dont think hes that bad, but its bad enough that he says he doesnt need a meter and when he jumps something and it works then he knows what part is the...
-
So it wouldnt be wrong of me to tell him he has to take his meter into every call then if its a safety concern.
He does have one of those light up testers but i dont know about you, but i cannot...
-
Thats what this guy does and hes never gotten a call done in less than an hour it drives me crazy. Goes in no tools, walks back out has a smoke and goes back in with some tools, forgets something...
-
Wage depends on experience and licenses but if for a G2 with a 313D or 313A it would be $25-$30/hour for residential
There is a whole health benefits package that includes 80% on prescriptions,...
-
Are you looking for a job in Windsor On??
-
When doing No heat and no cooling calls, how many of you bring your meter in on every call?
I think this is a stupid question as i do on every single call BBBBBUUUUTTTT I just had an employee tell...
-
Looking for service techs, lead installer and a helper in windsor Ontario.
Good wages and benefits. Great smaller company to work at! Apply with resume to my email!
-
I think you are right, its been 10 days since going there, just waiting to see if it happens again
-
Thank you for the manual, i could jot find that one amywhere! 6 flashes says HSI failure which is strange because it looks good and ohms out ok. I was thinking it may be the board because its...
-
Thats the thing it works fine every time i go there. But once when i arrived it flashed 6 times. Thats the only time i saw that fault and theres nothing that says flash codes. I pulled hose of...
-
Lennox mid efficiency g24m3-75a-1
This furnace has one LED light not two and i cannot find the flash codes anywhere. Does anyone have this?
I keep getting six flash code and cant figure out whats...
-
Hi guys, I have been on this site for about 7 years and in the HVAC industry for 12 years, my commonlaw wife was diagnosed with cancer about a year ago. We just found out it is very aggressive and...
-
Thank you! I will keep you posted
-
I will post diagram tomorrow while im there.
-
No pic of the diagram, sorry I didnt see the reply until now. Found a melted pin connector At the condenser fan motor and saw a spark from there while running. First time I actually saw the fuse...
-
-
working on a Lennox rooftop unit 575 volt envy first visit there I found the fuses for the condenser fan motors both alone replace the fuses and checked for shorts to ground and checked relays and...
-
Also how does the sprayer work? air compressor? hand pump? sorry guys no one at any company ive worked at has ever had one
-
To you guys that use tank sprayers, this might sound like a stupid question but what do you rinse the coil with afterwords, ive never used one, i do maybe 10-12 commercial maintenance jobs myself and...
-
Can you email me prices and pics on the recovery machine, turbo torch and vacuum gauge? Thanks
-
Ya randys a good teacher!
-
I'm in advanced at mohawk right now, I'm going to write in january hopefully, I heard there was 4 different tests and some were harder then others I can't wait to get it over with tho
-
Working on a carrier M# 50rhr036scc51130
S# 3805v19316
Keeps locking out, can't figure out why water into the unit 80f water out 125f
Suction pressure 75 psig
Discharge,before entering condenser...
-
so that is a seperate device? do u have a website?
thanks
-
Does anyone have an all in one hvac tool that you can input info to determine superheat, p/t charts, ductulator and heat load all in one? and how do you like it?
would you prefer a hand held...
-
So it will be R408A in the system will it not?
-
Its on for about 10 minutes before it has a heavy frost on it back to the compressor and eventually starts to ice up
-
I got a call today for a Hoshizaki Ice Maker, model KM-250BAC, i dont really work on ice makers that often so any help would be appreciated, It has a Copeland Compressor M# RSU4-0050-1AA-908
S#...
-
Lmao!!! sorry i didnt even know they gave me the professional member!
-
well can i get an answer because they never gave me a proffesional membership, i have probably 50 posts and you only need 10 for proffessional and i have my g2 and has been to school twice for...
-
confused:What is the best things to do for a residential boiler maintenance, i usually, clean the burners check gas pressure, check expansion tank pressure, bleed air at bleeders if needed, amp pump,...
-
your right i shouldnt think the same scenario before i get there, but ive always been meaing to ask about these high pressure switches on those units, because i have reset them before and never gone...
-
On the old lennox condensers, i dont have the numbers with me but those old grey ones, they have a red reset button for high pressure underneath the electrical access panel or above the gauge ports,...
-
I dont work on chillers that often but i am required to change a compressor on a trane chiller for a customer of ours, what steps are required that would differ from a commercial rooftop package...
-
I was working on a yorkrooftop unit last week and the breaker in the disconnect (100amp 3 phase commander breaker) was no good, i had proper voltage at line side and missing 1 leg of 3 phase on load...
-
I was working on a bradford white hot water tank today the M# is MITW40L6BN15
S#BF6365642
Tank would ignite and run for 10 to 20 sec and flame would shut off, it would do this over and over...
-
My company always hires out air balancing on commercial jobs, is there any course or any good way to learn air balancing? i know you need some expensive tools for it but i dont know anything about...
-
Has anyone ran into this problem? i have seen it a few times... people with 30 or 40 year old olsen or clare heckla low boys changing from a mechanical t-stat to a cheapo digital programmable...
-
what is the best zebra analyzer?
-
whats a zebra analyzer and how does it work?
-
Went to a call in the middle of the night yesterday, i had a DC variable speed motor not running, i dont have much experience with these types of systems, 2 years in the trade and my company mostly...
|
|