  1. Replies
    11
    Views
    193

    You have a legitimate complaint. No mastic...

    You have a legitimate complaint.

    No mastic
    No smooth transitions
    Sharp edges posing safety hazards

    Basically I wouldnít accept it!
  2. I looked this morning, there sites changed. The...

    I looked this morning, there sites changed.
    The idea was to prevent adding N2 to a full charge and claiming itís a trace gas!
  3. Replies
    10
    Views
    97

    Absolutely! The copper will fail before the...

    Absolutely!

    The copper will fail before the joint.
  4. Replies
    10
    Views
    97

    This is where I prefer Stay Brite #8 but thatís...

    This is where I prefer Stay Brite #8 but thatís another argument!
  5. Replies
    10
    Views
    97

    Check with the factory but every class Iíve taken...

    Check with the factory but every class Iíve taken says NO.

    Remember there are fine screens everywhere that plugg easy.
  6. Replies
    30
    Views
    449

    Condos are generally built with the same size...

    Condos are generally built with the same size units and duct layouts. The GC doesnít care if itís right fist that itís cheap.

    You can ASSUME anything you want. Has static pressure been measured.
  7. There has to be more to this story! You got...

    There has to be more to this story!

    You got them to change a new condensing unit from single stage to 2 stage?
  8. Replies
    10
    Views
    97

    No

    No
  9. Replies
    2
    Views
    59

    Hard pipe Sealed ???

    Hard pipe
    Sealed
    ???
  10. Replies
    11
    Views
    193

    Thereís a contractor map on this site. Heating...

    Thereís a contractor map on this site.
    Heating help dot com is another good site with more contractors.

    Thermo Pride will have one also.
  11. Replies
    11
    Views
    193

    *

    *
  12. Replies
    11
    Views
    193

    Sent from the OP All images are sideways

    Sent from the OP

    All images are sideways
  13. Replies
    3
    Views
    78

    The venting requirements are pretty straight...

    The venting requirements are pretty straight forward in the manual. Do a search for and get a copy.

    I would still get a second opinion, the new tech may be a salesman!
  14. Replies
    30
    Views
    449

    A more restrictive filter will make a bad...

    A more restrictive filter will make a bad situation worse YES. Did it kill the motor NO that motor was probably on its way out anyway!

    Maybe the ducts are sized correctly for a smaller unit ( I...
  15. Replies
    30
    Views
    449

    ECM's fail due to constantly fighting trying to...

    ECM's fail due to constantly fighting trying to meet the air flow requirements! That's not the ECM's fault that's the typical oversized equipment on undersized ducts Piss Poor Installs!
  16. Replies
    30
    Views
    449

    Where are you reading that? Dirty or clogged...

    Where are you reading that?

    Dirty or clogged air filters lead to less air flow and frozen coils!
  17. Replies
    11
    Views
    193

    How big is this house? where is it located? ...

    How big is this house?

    where is it located?

    That's a lot of furnace for new construction!
  18. Replies
    11
    Views
    193

    Send the pics to me (emails in profile) I'll post...

    Send the pics to me (emails in profile) I'll post them!
  19. That's to prevent someone from claiming the...

    That's to prevent someone from claiming the remaining charge is now a Leak Test too get around recovering it!
  20. Adding N2 to the remaining charge for leak...

    Adding N2 to the remaining charge for leak checking is Illegal. (Good Luck with that. Inform your local DEC / EPA if you want)

    Pressurizing the system with 5PSIG of R-22 and following with N@ is...
  21. Replies
    30
    Views
    449

    Squirrel cage fans AKA centrifugal fans "Throw...

    Squirrel cage fans AKA centrifugal fans "Throw the air"! if you restrict the inlet or outlet the wheel just spins, less work is being done, less air is being moved so less amperage or electrical is...
  22. Replies
    16
    Views
    433

    This is the best statement I've seen in a while!...

    This is the best statement I've seen in a while!

    Your going to go far in this industry! :cheers:
  23. Replies
    12
    Views
    191

    Sucks getting old!

    Sucks getting old!
  24. Replies
    30
    Views
    449

    Sorry to say that restricting the air flow...

    Sorry to say that restricting the air flow actually lowers the power consumption (AKA Amperage) of the blower motor, so in your case I feel the motor and or capacitor were already doomed the filter...
  25. Replies
    2
    Views
    156

    I wonder about the warranty with being out of...

    I wonder about the warranty with being out of level!
  26. Replies
    8
    Views
    158

    So your changing a perfectly good compressor? ...

    So your changing a perfectly good compressor?

    With POE make room for a suction filter.
  27. Tell the management company to pay someone to...

    Tell the management company to pay someone to hook it up!

    You shouldnít accept the responsibility in any shape or form!
  28. Replies
    8
    Views
    158

    Evap and compressor. Why did the compressor...

    Evap and compressor.

    Why did the compressor fail?

    Change the whole unit youíve got a 12 year old water cooled condenser that will probably fail sooner then later!
  29. Nest is POO

    Nest is POO
  30. Replies
    13
    Views
    301

    I got off them early. Helps having a Daughter...

    I got off them early.

    Helps having a Daughter with a medical degree!

    My issue was the pain meds, 100 hits of oxy for 30 days with 2 refills. Wonder why thereís a opioid problem!
  31. Find a different service provider!

    Find a different service provider!
  32. Replies
    10
    Views
    301

    Do you realize how lucky you are extra wires were...

    Do you realize how lucky you are extra wires were pulled!
  33. When those ducts were first sized the equipment...

    When those ducts were first sized the equipment was a low velocity high temperature system. Todayís equipment is higher velocity lower temperatures.
    The two really donít work well together.
  34. Replies
    13
    Views
    318

    FWIW Mr Bill Itís a nation wide problem!

    FWIW Mr Bill

    Itís a nation wide problem!
  35. Replies
    13
    Views
    301

    It will be 8 years in Feb since my Quadruple. ...

    It will be 8 years in Feb since my Quadruple.

    Take it real easy on the pain meds and Listen to the physical therapist, Get that mussel mass back that's the fastest and best way to recover.
    ...
  36. I personally don't have a problem with Dye if...

    I personally don't have a problem with Dye if done properly, Obviously in this case it was not. Dump the oil and change it. This will also deal with any possible moisture issues!

    As far as the 3...
  37. You really donít want to hear what I have to say!

    You really donít want to hear what I have to say!
  38. Keep searching on the net...... Increase your...

    Keep searching on the net......
    Increase your fire insurance and get a Low level CO detector!
  39. Replies
    1
    Views
    156

    Pull the charge and weigh it! Straighten out...

    Pull the charge and weigh it!

    Straighten out the kinks!
  40. Find a different tech!

    Find a different tech!
  41. Replies
    13
    Views
    318

    Unfortunately thatís the way it is. 50 - 75%...

    Unfortunately thatís the way it is.

    50 - 75% of the techs are not qualified or are sales techs.

    Once you find one take real good care of him / her!
  42. Replies
    17
    Views
    321

    In N O Dump the Carrier Get a 90+% furnace

    In N O
    Dump the Carrier

    Get a 90+% furnace
  43. They were having leak issues early on.

    They were having leak issues early on.
  44. How did you decide on 4-Tons? How many CFMís...

    How did you decide on 4-Tons?

    How many CFMís can the existing duct handle?
  45. Replies
    7
    Views
    200

    Get a mini split!

    Get a mini split!
  46. Replies
    7
    Views
    203

    and we have to do the same thing, check the...

    and we have to do the same thing, check the entire Low Voltage Circuit!
  47. Itís Crap!

    Itís Crap!
  48. Replies
    7
    Views
    203

    Everything in the low voltage circuit!

    Everything in the low voltage circuit!
  49. it sounds like the control is calling for whatís...

    it sounds like the control is calling for whatís needed!
  50. Replies
    4
    Views
    248

    At design conditions yes it will run all the...

    At design conditions yes it will run all the time. Unless the unit was sized for cooling I would expect a few cycles overnight at 32*F