Search:

Type: Posts; User: BNME8EZ

Page 1 of 20 1 2 3 4

Search: Search took 0.16 seconds.

  1. Replies
    836
    Views
    130,055

    This is the first game for the Huskers this...

    This is the first game for the Huskers this season so this seems a fitting tribute. This is not the first tunnel walk that I saw but it is similar. When the trophies land on the stadium i swear you...
  2. Replies
    836
    Views
    130,055

    This one is fun for a Saturday ...

    This one is fun for a Saturday


    https://youtu.be/Q7DniRWRA7s
  3. Replies
    836
    Views
    130,055

    This one id kinda fun ...

    This one id kinda fun


    https://youtu.be/7Lb9dq-JZFI
  4. Replies
    9
    Views
    333

    So you were paying a friend that was not paying...

    So you were paying a friend that was not paying taxes, not paying for any insurance, not paying rent/mortgage on a building/shop to work out of, had no overhead at all to pay so every dime you paid...
  5. Unless it is like a mounting bracket but then...

    Unless it is like a mounting bracket but then what would be the sense of the window?

    I don't have side windows but do have a 4' step ladder mounted on the inside of the rear of the 2 side doors...
  6. They have seen the back of your old van and the...

    They have seen the back of your old van and the way you drive so those are to protect the window from flying parts.

    Really I don't know but they may be a theft protection device, as in can't...
  7. Replies
    9
    Views
    333

    So If I understand correctly you have installed...

    So If I understand correctly you have installed everything except the line set and you want a company to run the lines, silver solder them, evacuate them to below 500 microns, release the...
  8. Replies
    6
    Views
    196

    The blower output will depend on what they, the...

    The blower output will depend on what they, the installers set it at but the BTU output will be roughly what is listed on the unit for 1st and 2nd stages. If the installers do their job they will...
  9. Replies
    8
    Views
    322

    Did you try cycling the power. I changed a...

    Did you try cycling the power.

    I changed a filter that had to go in through the blower door. Put the door back on saw the lights on the board come on and left. I got a call the next day the...
  10. Replies
    8
    Views
    322

    It seems like it takes several minutes for them...

    It seems like it takes several minutes for them to do their thing. But usually the 824's anyway have a circle of dots that spin and says initializing. The 624 is cheaper version so it may be blank....
  11. Replies
    2
    Views
    242

    I have dealt with this many times, too many. It...

    I have dealt with this many times, too many. It is a harmonics from the compressor that is carrying on a line. You can try to find the correct spot to put a weight to absorb the vibration and may...
  12. Replies
    8
    Views
    322

    Did it ever come back on? I have never dealt...

    Did it ever come back on? I have never dealt with a 624 but have a lot of 824's out there. That is the one thing I hate about them is that they have to reboot and go through what appears as the...
  13. Replies
    11
    Views
    284

    I'm sorry but you lost me here. If the grill...

    I'm sorry but you lost me here. If the grill goes across 2 studs that would be 1 stud space if it goes across 3 that would be a double. Are you saying that the grill touches 4 studs so 3 spaces?
  14. Replies
    11
    Views
    284

    Am I understanding it goes up inside the wall? ...

    Am I understanding it goes up inside the wall? How big is this return? A 3.5" stud space will only move about 150 CFM so if it is a double there you go, that's your 340ish. So if you are getting...
  15. Replies
    11
    Views
    284

    Since you measured the return, did you measure...

    Since you measured the return, did you measure the supply registers for air flow? It seem to me that if close to 3/4 of the restriction is on the supply side Then that would be the first place to...
  16. This is experience talking here, only did it once...

    This is experience talking here, only did it once but that was enough. Do not, repeat, do not try to adjust the heat anticipator while the equipment is running. You will burn out the HA every time....
  17. Replies
    23
    Views
    564

    I carry a tube of RTV silicone in the Analyzer...

    I carry a tube of RTV silicone in the Analyzer box. half a tube and your good to go. Just kidding. You can fill the hole then put a bit more around the outside of the hole to create a flange. If...
  18. Not a Ruud dealer but at one time we sold Trane...

    Not a Ruud dealer but at one time we sold Trane and Bryant almost 50/50. While I can't say we had shorter life out of the Bryant we did notice especially with the furnaces we had more breakdowns. ...
  19. I agree to a point Bill. The biggest problem I...

    I agree to a point Bill. The biggest problem I have is I never see some of this equipment, like there is not a Lennox dealer within 40 miles, on the dealers that are in my area I don't memorize...
  20. I liked your post Mr Bill. I always thought I...

    I liked your post Mr Bill. I always thought I was just a Trane snob as I never agreed that brand doesn't matter, just kept my fingers shut. Couldn't see starting a flame war over something so...
  21. Replies
    21
    Views
    546

    Rather than buy8iing a new one, just lower the...

    Rather than buy8iing a new one, just lower the temp on that one and see if it does better.
  22. Replies
    21
    Views
    546

    Ok, so it is not just a feeling it was a measured...

    Ok, so it is not just a feeling it was a measured temperature. Was the thermostat replaced or is it the same one. Not every thermostat is calibrated the same, some have a way to adjust for...
  23. I don't think the question is if it will run or...

    I don't think the question is if it will run or not but how well will it run.

    If you push a wheelbarrow, empty, down hill, it tells you very little about how strong you are or how well you are...
  24. Replies
    21
    Views
    546

    But is the actual temp 75 and feels 78 or is it...

    But is the actual temp 75 and feels 78 or is it actually 78?
  25. My guess is it was put in the case on a bind and...

    My guess is it was put in the case on a bind and over time it popped the seam. I have seen mine get loose over time from use. You start noticing the probe will wiggle in the handle.
  26. Replies
    33
    Views
    1,188

    Have you tried just calling NCI? I have talked...

    Have you tried just calling NCI? I have talked to them many times about classes that have been canceled in my area from lack of registrations, discussing things like alternate sites, timing, etc.
  27. Replies
    21
    Views
    546

    How much does the new system run compared to the...

    How much does the new system run compared to the old?

    What is the actual temp when you feel it is higher than set point?
  28. Replies
    33
    Views
    1,188

    I have a minimum charge for the use of the CA to...

    I have a minimum charge for the use of the CA to cover upkeep. It is not an option. If I touch a furnace it gets tested. The only time I have not done a CA on a gas appliance I was working on was...
  29. Replies
    21
    Views
    546

    SEER rating is done at a very specific set of...

    SEER rating is done at a very specific set of conditions, very hard to duplicate in the field so it is doubtful they know SEER rating but they could have gotten and EER rating which is similar.

    If...
  30. And it does not run long enough to foam the oil...

    And it does not run long enough to foam the oil and move much oil out of the sump.
  31. I have done that on new start ups where the...

    I have done that on new start ups where the heater has not had sufficient time to warm the compressor completely. Have never had one fail on me.
  32. Replies
    10
    Views
    340

    I did not see where you said the ducts ere...

    I did not see where you said the ducts ere located but since we are talking Texas I will assume the attic. You also said the the roof was spray foamed and the ceiling insulation was removed. This...
  33. I would not do it but like Baldloonie says winter...

    I would not do it but like Baldloonie says winter temps can be +/- "0". I have not seen a A/C with a heater for years, heat pumps yes. If it is a heat pump system I would go with the assumption...
  34. Thread: Trane S9B1C100

    by BNME8EZ
    Replies
    15
    Views
    458

    I found it in the paperwork sent with the...

    I found it in the paperwork sent with the equipment. Maybe they need to put on the outside of the bag that holds them "If your way doesn't work, try ours"!
  35. Replies
    836
    Views
    130,055

    Here is a little bit different take on an old...

    Here is a little bit different take on an old song


    https://youtu.be/apal3VnZpPo
  36. I would not try to operate both system from the...

    I would not try to operate both system from the stat directly, put in an isolation relay(s) to run the boiler, let the stat run the relay(s). That will be easier than trying to twin transformers...
  37. Interesting, I don’t remember ever seeing that...

    Interesting, I don’t remember ever seeing that high of CO with that high of O2.
  38. Replies
    134
    Views
    3,422

    Congratulations. A lot of guys would have thrown...

    Congratulations. A lot of guys would have thrown in the towel and sold a new unit. Good job sticking with it and adding another feather to your cap.
  39. Replies
    134
    Views
    3,422

    Let me give you a small clue and you can go look...

    Let me give you a small clue and you can go look from there. What happens if you have a compressor rated for 18k and a TXV rated for 48k? Or reversed?
  40. Replies
    134
    Views
    3,422

    Actually yes it does. Not going to go into great...

    Actually yes it does. Not going to go into great detail but none of these components operate in a vacuum except maybe in refrigeration (inside joke). So you can not size A without considering B, C,...
  41. Replies
    25
    Views
    677

    The ones I have dealt with you drive open the EEV...

    The ones I have dealt with you drive open the EEV and start the system the EEV starts to react very quickly and settles into the right setting for proper SH.
  42. I have done that test, the flame turns orange. ...

    I have done that test, the flame turns orange. When I have been involved in those tests there were 2 of us, one spraying the flames the other with the torch at the registers.
  43. Replies
    25
    Views
    677

    Why not just jumper the test pins and force it...

    Why not just jumper the test pins and force it open then start the system rather than run the system in pump down conditions?
  44. I use the CA and to my knowledge have not...

    I use the CA and to my knowledge have not condemned a good one yet.

    The first one I did I checked the HX when I pulled it out, could not find a problem with it anywhere, but the CO would...
  45. Replies
    25
    Views
    677

    I like the list with one adjustment. The time...

    I like the list with one adjustment. The time delays need to be delay on break. I have seen several systems with a 5 minute delay built into the stat and another in the condenser and you can have a...
  46. Replies
    25
    Views
    677

    Interesting, I have not had an issue with Trane's...

    Interesting, I have not had an issue with Trane's EEV's. I do have a System that will lock out in the spring. It is a Commercial building with 2 4T systems. The one system was there the other I...
  47. Replies
    134
    Views
    3,422

    I'm sorry, I didn't understand this part in blue....

    I'm sorry, I didn't understand this part in blue. I am assuming you meant to say 3T condenser.

    I don't want to start a flame war here or anything but I have been told on multiple occasions by...
  48. You would see the temperature of the cell as you...

    You would see the temperature of the cell as you probed it, so it is part of the monitoring process. I have also seen enough of these standing pilot furnaces to know it is very common for the baffle...
  49. Thread: The Ozone Hole

    by BNME8EZ
    Replies
    51
    Views
    1,732

    Now that you say that it seems like it was the...

    Now that you say that it seems like it was the tight Hydrogen bond that wouldn't break down easily that made it the problem.
  50. Replies
    25
    Views
    677

    Not sticking up for manufacturers here but we...

    Not sticking up for manufacturers here but we often don't think about it from a dean counter stand point. A pressure switch may cost a manufacturer $10 each considering the quantity they would...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4