    Correct Duct Sizing

    I am finishing an attic, turning it into two rooms, a master bedroom and master bath and need to run duct from my furnace in the basement up to the attic. The room dimensions will be 10 x 11 for the bathroom and 10 x 21 for the bedroom, both with 8' ceilings. I will also have a 7 x 8 walk-in closet off the MB. I've gotten a couple quotes to do this job, but they are slightly different on the duct size. Both want to supply the upstairs with an 8 x 12 rectangular duct, but on the return, one wants to use 8" round, and the other 10" round or another 8 x 12 rectangular. They will feed plenums in the attic which will then have flexible ducts to the registers. Since I am bringing the feed ducts up along a wall, I will have to build out the wall some to accommodate them, and I don't want to bring out the wall any further than absolutely necessary, as space is an issue in that location. First off, is round duct better for airflow than square or rectangular? If it is, can I go with 8" instead of the 10"? If round is really not any better, I will just go with the 8 x 12 as this will give a bigger duct area assuming the contractor does not want a whole lot more to do it that way. Also, does the walk-in closet need it's own register and feed? I plan on having the whole underside of the roof and walls insulated with spray on foam, so the whole attic will be a conditioned space, if that makes any difference in the equation. Do the plenums in the attic then have to be insulated?

  2. #2
    Join Date
    Dec 2010
    Location
    The Quad-Cities area (midwest).
    Posts
    2,927
    Post Likes
    I would strongly recommend a seperate system to handle that area.

  3. #3
    Join Date
    May 2008
    Location
    Central Fla.
    Posts
    311
    Post Likes
    Quote Originally Posted by George2 View Post
    I would strongly recommend a seperate system to handle that area.
    +1 a mini-split would be nice up there.

  4. #4
    Join Date
    Dec 2010
    Location
    The Quad-Cities area (midwest).
    Posts
    2,927
    Post Likes
    Quote Originally Posted by TwincamDave View Post
    +1 a mini-split would be nice up there.
    That's what I was thinking. I'm surprised his HVAC contractors didn't suggest one.

Quick Reply Quick Reply

Register Now

Please enter the name by which you would like to log-in and be known on this site.

Please enter a password for your user account. Note that passwords are case-sensitive.

Please enter a valid email address for yourself.

Log-in

Posting Permissions

  • You may post new threads
  • You may post replies
  • You may not post attachments
  • You may not edit your posts
  •