Thread: low loss adapter

  1. #21
    Join Date
    Sep 2004
    Posts
    13,938
    Post Likes
    its okay that you are a meatball now!!!!!!!!!!!!!!!!!!!!!!!

    never mad at u

    i thought that was off of a mammoth ??????????????

    looks exactly the same???????

    ribbon cables and fuses in the exact same place

    Quote Originally Posted by BergerMech Rob View Post
    It's a Mcquay Microtech 200 controller - they don't need calibration!!!!

    I thought you were mad at me because I work for the big non-union meatball now!!!

    lol
    true knowledge exists in knowing that you know nothing.

  2. #22
    Join Date
    Sep 2004
    Posts
    13,938
    Post Likes
    it is the exact same controller!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !


    in the first menu after password, mode-occupied/unoccupied/remote start
    next item calibration

    but ofcourse that was for a varicone vane controller..

    i would live on the edge and guess there is NO varicone vane for duct static control?? LOL

    but it is the exact same board

    i have 4 of them in my truck

    just grabbed one and compared it to your avatar


    how is work????????????????????
    true knowledge exists in knowing that you know nothing.

  3. #23
    Join Date
    Feb 2004
    Location
    Midwest
    Posts
    9,955
    Post Likes
    What about blow-back from the ones with the ball valves vs. the low loss ones - like when you're unscrewing the hi side hose from the Shrader?

  4. #24
    Join Date
    Mar 2007
    Posts
    3,824
    Post Likes
    Quote Originally Posted by supertek65 View Post
    it is the exact same controller!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !


    in the first menu after password, mode-occupied/unoccupied/remote start
    next item calibration

    but ofcourse that was for a varicone vane controller..

    i would live on the edge and guess there is NO varicone vane for duct static control?? LOL

    but it is the exact same board

    i have 4 of them in my truck

    just grabbed one and compared it to your avatar


    how is work????????????????????
    Work is cool - Making more money than I ever have, I haven't put in any OT that I didn't ask for, I'm learning something new every day, and I'm enjoying being a little fish in a big pond.

    There's some chiller porn in the "office pictures" thread that I posted.
    Don't pick the fly crap out of the pepper.

  5. #25
    Join Date
    Mar 2007
    Posts
    3,824
    Post Likes
    Quote Originally Posted by midhvac View Post
    What about blow-back from the ones with the ball valves vs. the low loss ones - like when you're unscrewing the hi side hose from the Shrader?
    Never really been much of a problem for me. Sure, it's a tiny bit more than the "psst" you get from a low-loss, but the fittings are so much more reliable and useful.
    Don't pick the fly crap out of the pepper.

  6. #26
    Join Date
    Sep 2004
    Posts
    13,938
    Post Likes
    chiller porn!!!!!!!!!!

    I'm there!!!!!!!!!!!!!!!!!



    Quote Originally Posted by BergerMech Rob View Post
    Work is cool - Making more money than I ever have, I haven't put in any OT that I didn't ask for, I'm learning something new every day, and I'm enjoying being a little fish in a big pond.

    There's some chiller porn in the "office pictures" thread that I posted.
    true knowledge exists in knowing that you know nothing.

  7. #27
    Join Date
    Dec 2005
    Posts
    7,904
    Post Likes
    I also like the YJ's with the ball valve built in at the end. Its better than anything else I've used over time.

    I have these. I haven't tried them yet, but they look promising. Has anyone else used them? Are they any good?






  8. #28
    Join Date
    Sep 2004
    Posts
    13,938
    Post Likes
    those look great!!
    for guys working on small krapp there might be a problem getting them to fit sometimes


    Quote Originally Posted by newoldtech View Post
    I also like the YJ's with the ball valve built in at the end. Its better than anything else I've used over time.

    I have these. I haven't tried them yet, but they look promising. Has anyone else used them? Are they any good?





    true knowledge exists in knowing that you know nothing.

  9. #29
    Join Date
    Nov 2013
    Posts
    1
    Post Likes

    mark simms hvac

    Quote Originally Posted by adamste81 View Post
    need help with finding a low loss fitting for the high side of my gauges. the manifold i bought did not come with low loss fittings on the hoses so i need an adapter. teacher told us we could find them for $10-$15 but so far all I see online is $40-$50. anyone know a good place to find this piece? thanks in advance.
    .you can order from johnstone hvac supply house on line,i seen it for 20 dollars on that website.

  10. #30
    Join Date
    Oct 2013
    Location
    Mobile, Alabama, United States
    Posts
    325
    Post Likes
    I think that the OP probably has what they need by now..... 3 years later

  11. Likes Fot liked this post.
  12. #31
    Join Date
    Feb 2017
    Location
    Braselton, GA
    Posts
    15
    Post Likes
    Does anyone know if the Yellow Jacket 25980 9" charging hoses with ball valves are rebuild-able? I have a set and the red hose has a leak at the valve stem. I have searched high and low and cannot find any information or parts to rebuild. Hate to just toss them and drop another $90 on a new set if it is possible to take apart and rebuild.

  13. #32
    Join Date
    Feb 2017
    Location
    Braselton, GA
    Posts
    15
    Post Likes
    UPDATE: Just got off the phone with Yellow Jacket and according to their tech, the YJ 25980 9" hoses with ball valves are not rebuild-able and there are no parts to rebuild. Just thought i'd post this in case someone else out there has a set of these and is wondering if it is possible to rebuild them.

  14. #33
    Join Date
    Dec 2011
    Location
    hartford ct
    Posts
    9
    Post Likes
    Ball valves are the way to go. after closing them off, press the fitting hard against the access port, so you make a good seal, then undo the nut to the last thread and pull the fitting off the access port quickly. using this method i believe i lose less then if i use a low-loss (this is much easiear to demonstrate then it is to explain)

    Dont get the adapters that screw into the hoses. they may work, but i guarantee that at some point you will go to use them, they will have loosened up, you will not notice, and you will dump an entire systems charge while trying to figure out what is happening.

    If you do use Low-loss fittings, dont use them on 410a... from everything i heard they dont stand up to the pressures

  15. #34
    Join Date
    Oct 2012
    Location
    Danville, KY
    Posts
    348
    Post Likes
    Quote Originally Posted by Mustangman66 View Post
    Ball valves are the way to go. after closing them off, press the fitting hard against the access port, so you make a good seal, then undo the nut to the last thread and pull the fitting off the access port quickly. using this method i believe i lose less then if i use a low-loss (this is much easiear to demonstrate then it is to explain)

    Dont get the adapters that screw into the hoses. they may work, but i guarantee that at some point you will go to use them, they will have loosened up, you will not notice, and you will dump an entire systems charge while trying to figure out what is happening.

    If you do use Low-loss fittings, dont use them on 410a... from everything i heard they dont stand up to the pressures
    NRP low loss are only ones I know of rated for 410a pressures.

  16. #35
    Join Date
    Jul 2018
    Location
    Phoenix
    Posts
    12
    Post Likes
    This makes no since but I’m probably dumb then why does ball valves help from refrigerant spray when disconnecting your hoses when all it does is restrict gas from going into your hose when the spray occurs from the service valve

  17. #36
    Join Date
    Jul 2018
    Location
    Phoenix
    Posts
    12
    Post Likes
    So basically your saying ball valves are good but also saying you still have to remove the hoses quick because gas will spray out so why when people want a answer to reducing the spray upon disconnecting your hoses ball valves are the way to go.

  18. #37
    Join Date
    Dec 2005
    Posts
    7,904
    Post Likes
    Quote Originally Posted by Tomoson View Post
    This makes no since but I’m probably dumb then why does ball valves help from refrigerant spray when disconnecting your hoses when all it does is restrict gas from going into your hose when the spray occurs from the service valve
    Closing the ball valve keeps all the refrigerant that's in the hose from spraying out. I don't think the service valve is where you get much if any spray.

  19. Likes Fender60 liked this post.
  20. #38
    Join Date
    Mar 2018
    Location
    Sumter, SC
    Posts
    788
    Post Likes
    I am just a student at a local tech school, so my "experience" is non-existent compared to the pros here. However, we do have a plethora of gauges and hoses we use. On my own I have come to the conclusion that the hoses with ball valves are excellent and far out perform the hoses with low loss fittings we have. Just my $0.02

+ Reply to Thread
Page 2 of 2 FirstFirst 12

Quick Reply Quick Reply

Register Now

Please enter the name by which you would like to log-in and be known on this site.

Please enter a password for your user account. Note that passwords are case-sensitive.

Please enter a valid email address for yourself.

Log-in

Posting Permissions

  • You may post new threads
  • You may post replies
  • You may not post attachments
  • You may not edit your posts
  •