my mother just had this unit installed and she had no clue till 4 days after install filter rack comes crashing down... Come to find out they have it secured to air handler with tape ???
Is this a normal practice???? lots of dollars later and there is a rack attached by tape !!! would we allow this in any other service industry..
example surround sound wires held with thumb tack
when i spoke to the manager he stated this was a normal practice and argued that this is how it is done
now as you should be able to see in the pics there is plenty of room to fit a bracket to hold the rack to the handler why use tape?
any input would be greatly appreciatedAttachment 7494
Attachment 7495
Attachment 7496
Attachment 7497
Attachment 7498
Attachment 7499
Attachment 7500
Last edited by secureone; 05-29-2008 at 04:29 PM.
Last edited by secureone; 05-29-2008 at 03:29 PM. Reason: pics all over
Site rules don't allow the posting of dollar amounts. You should edit that out.
Normal procedure is not to connect a filter rack to a unit with only tape.
Question: Where is this air handler located in the house? From the pictures it looks to be just hanging from a wall somewhere with no return air ductwork connected to it.
Use the biggest hammer you like, pounding a square peg into a round hole does not equal a proper fit.
The tape is NOT suppose to support the air filter brackett.
The flanges on teh brackett are for using screws to mount the brackett to the unit.
They should either use a different brackett with your air handler, or use support bracketts to fasten that brackett to your air handler.
Guessing no permit was pulled for that install.
call the hack back.......
i have a supervisor coming on tues but think it is the same guy that told me its a normal practice ..
i just feel like smacking these people in the back of the head with a wrench because they think the consumer is a moron
i could attach that rack permanently with a 3 dollar trip to home depot
once again thanks for the input just wanted to make sure redneck rigging wasn't part of an industry standard
<removed company name>
Last edited by jrbenny; 06-01-2008 at 03:32 PM.
Is that a condo type unit? Why not use a front pull unit with the built in filter rack?
nope 2 story town home Attachment 7506
Am I the only one thinking low bid?
Use the biggest hammer you like, pounding a square peg into a round hole does not equal a proper fit.
hope they used more than tape to hold up the unit..
ok got off phone with rheem who states for installation of external filter rack secure rack to unit and seal with duct tape ...
keyword secure they figured seal and secure with tape would be fine!!!
I wasn't clear [that happens sometimes]. I meant that the unit is not hooked up to return duct and is just pulling the return from a closet, as shown from your picture.
I was curious as to why the contractor didn't use a front pull through type unit where the filter rack is built into the unit. That would have cut down on work and you could squeeze a small water heater underneath there if you needed to [that's the typical set up I see down here in townhomes& condos].
I can't quickly find any pictures online of what I'm talking about but I know Bryant makes one and pretty sure Rheem does too.
Another question, how come he fabricated a filter rack and didn't use one of the ones from Rheem that attach to the unit at the bottom? It's only 1.5 inches thick, if that, and it's just as good.
Maybe it's easier to judge in hindsight.
There is nothing wrong with using tape to secure the two together as long as the weight of the unit is pushing down on the filter rack against another hard surface. In your application, they needed to use a few screws and tape to hold it up. Since they went to the trouble (I hope) of securing the unit to a wall, it would have taken another 5 minutes to drive a few screws between the rack and air handler. You also need to make sure that where the plenum penetrates into the attic or between floors that it is sealed very well, as well as the entire closet, otherwise you will be pulling in attic air and whatever else surrounds it.
I hope that drain has a trap in it somewhere.
I never let schooling interfere with my education... Mark Twain
That is what I was just going to say, I would be more worried about a "p" trap being installed than that ez base filter rack. I have installed them with NO TAPE, just screw to floor of platform; run bead of silicone around top and sit air handler on top of rack.Tape is tacky, silicone or mastic if you want sealed. and Make sure that it also has wet-switch underneath the platform, if your drain stops up and leaks water, being on second floor it could do some real damage.
Inspection, make well have caught some of these issues.
'Life begins with the journey each day'
Well , I'll email them and ask them to post your name on the internet and see where it leads to . I'm saying give them a chance to make it right . And if they won't / can't do that then, bad mouth them . Being a contractor , I tend to side with like people. They could be low lifes or hacks . We don't know.
how bout this . If the supervisor would have ONCE apologized and stated he would correct the issue and customer satisfaction is a priority then I wouldn't have even posted this so.....
now if when they finally come out to resolve issue, if they do resolve it in a professional manner and apologize I will post it in the thread therefore people can make their own decision on if they select this company or not..
No matter what they do , pleasing you will be next to impossible . I'll email them Monday and see what the deal is . Then post your name as a customer to steer clear of .