  1. Replies
    12
    Views
    492

    Are you saying "king Valves" or plain service...

    Are you saying "king Valves" or plain service valves ?
    We use leak lock for kings, the non-hardening type.
    If its the regular, I have closed the valve and added some oil, then open and close...
  2. We have had several (5) compressors fail in these...

    We have had several (5) compressors fail in these units, the two stage Bristol design is very poor.
    All were verified mechanical failure.
    Our company is recommending full unit replacement just...
  3. Replies
    19
    Views
    1,811

    wow, I was thinking the same thing, my Beers...

    wow, I was thinking the same thing, my Beers warm !
    Won't that capacitor stay too warm, ie: not cool off during normal operation.
    Seems like the Rheem capacitors that hang in the air stay cooler...
  4. I have seen some quickie acid test deals at the...

    I have seen some quickie acid test deals at the supply house for very cheap, would be worth a $10 dollar test for some peace of mind. Just a thought.
    luck, dan
  5. Replies
    38
    Views
    1,396

    We do not get paid for travel to first call or...

    We do not get paid for travel to first call or home at night, with the exception of time over 45 min.
    and that's paid at regular or 1.5 rate if applicable.
    On emergency service we get paid port to...
  6. Replies
    15
    Views
    763

    I have the Fluke 52 series = it has treated me...

    I have the Fluke 52 series = it has treated me very well for 5+ years now.
    luck, dan
  7. Replies
    2
    Views
    250

    The ignition module usually has a wire terminal...

    The ignition module usually has a wire terminal labeled "burner ground",
    that's the one you jump into with you meter.
    luck, dan
  8. Replies
    2
    Views
    99

    You are not Kidding, we have about had "it". The...

    You are not Kidding, we have about had "it".
    The sun was shining today though.
    luck, dan
  9. Replies
    34
    Views
    1,623

    If you are installing the Eternal water heater, I...

    If you are installing the Eternal water heater, I believe you want a combustion analyzer = that's the best way to adjust the gas valve.
    luck, dan
  10. I would get it inspected by the installing...

    I would get it inspected by the installing contractor, the banging could be from thermal expansion or some failure.
    It would be nice for you to time the cycle = burner, noise, blower activation,...
  11. Well, my training from the manufactures rep. was...

    Well, my training from the manufactures rep. was that the eff. is the same at each stage and it's all about comfort.
    Long run times a whatever stage will heat the house with uniform temperature....
  12. Replies
    11
    Views
    528

    Overall the Pulse was a unique design that has...

    Overall the Pulse was a unique design that has performed well.
    Pressure testing yearly would be my recommendation.
    CO alarms of a low level type are appropriate for everyone.
    You are at the edge...
  13. If its a Infinity system with an Infinity...

    If its a Infinity system with an Infinity control, I'd be very upset, sounds like a design/software defect.
    They do make a wifi Infinity or several Honeywell with wifi that would do air-to-air HP, a...
  14. Replies
    6
    Views
    361

    We replace the whole assemble if noise is a...

    We replace the whole assemble if noise is a concern.
    luck, dan
  15. Did you ever see if fail yourself ? Have you...

    Did you ever see if fail yourself ?
    Have you ever seen the furnace without power and not tripped ?
    The rollout tripped is a warning sign of a bigger issue, I would get a tune-up done and look for...
  16. A home that big will have a lot of ductwork, I'd...

    A home that big will have a lot of ductwork, I'd suspect you need the house balanced to get a more uniform temperature in every room on the first stage heating.
    luck, dan
  17. Change the batteries in the thermostat and turn...

    Change the batteries in the thermostat and turn down the humidistat = see what happens.
    luck, dan
  18. what model of furnace and is there any warranty...

    what model of furnace and is there any warranty available on the HX ?
    what's the repair cost for the HX and the inducer assembly ?
    Some of us tech's want the best for the client,
    sometimes the...
  19. is this an 80% or 90% efficient ? luck, dan

    is this an 80% or 90% efficient ?
    luck, dan
  20. super stor , very good warranty and quality...

    super stor , very good warranty and quality product.
    luck, dan
  21. Replies
    9
    Views
    752

    Don't get fooled by any mech failer of the...

    Don't get fooled by any mech failer of the pressure switch tubing, had one that tricked me because of the tension on the tubing to the pressure switch would open the hole and the testing with the...
  22. if the t-stat is off the wall and you get the...

    if the t-stat is off the wall and you get the funny low voltage on the white wire, how could it be the thermostat issue ?
  23. Replies
    9
    Views
    567

    I've found down sizing the capacitor helps the...

    I've found down sizing the capacitor helps the "cavatitating sound".
    Please put hardware cloth over the openings, never know when a little kid shows up.
    Luck dan
  24. Replies
    4
    Views
    450

    Start Capacitor w/o Resistor

    Ordered some start capacitors from AmRad and they showed up without the resistor, seems funny ?
    Called the supply house we ordered from, he calls the Global rep = whom says " not really needed ",...
  25. what is the dats set at ? please add a 5 min...

    what is the dats set at ?
    please add a 5 min delay to the outdoor condenser to stop short cycling
    skinny the 2 floor damper open just a touch
    the heating season may be ok, beacause the heat rises...