Search:

Type: Posts; User: itsiceman

Page 1 of 20 1 2 3 4

Search: Search took 0.06 seconds.

  1. Replies
    25
    Views
    1,646

    On the back flap where the bottom of the shoulder...

    On the back flap where the bottom of the shoulder strap connects tore out the zipper where these ones only have one pass on the zipper. The front where there is much less stress IMO has two passes...
  2. Replies
    25
    Views
    1,646

    thanks Front flap and back flap?

    thanks
    Front flap and back flap?
  3. Replies
    781
    Views
    54,715

    Is the temp split trend SADB-RADB or something...

    Is the temp split trend SADB-RADB or something else?
  4. Replies
    54
    Views
    2,743

    You can use a SMAN as a stand alone gauge. ...

    You can use a SMAN as a stand alone gauge.
    Looks like Sponge Bob walking a tight rope on his wiener lol
    ...
  5. Replies
    54
    Views
    2,743

    Will see if the POE eats the vinyl I didn't...

    Will see if the POE eats the vinyl
    I didn't think to test it that before hand ;(
  6. Replies
    54
    Views
    2,743

    JB Platinum pumps don't have those issues. As...

    JB Platinum pumps don't have those issues.
    As far as how it worked it seemed to be good. Took a little time to put the oil back where it belonged lol
    The evac on the POE system went more like MO...
  7. Replies
    781
    Views
    54,715

    A UEi SSM1 has a list price of 225 (one pressure...

    A UEi SSM1 has a list price of 225
    (one pressure one temperature)
  8. Replies
    54
    Views
    2,743

    The clear hose was very nice today. Had a unit...

    The clear hose was very nice today.
    Had a unit that had a crack in a discharge and evidently the liquid line and condenser was full of oil and since the tube was large diameter there wasn't enough...
  9. Replies
    25
    Views
    1,646

    I've had a VETO for quite a few years. Got one...

    I've had a VETO for quite a few years. Got one around the same time I joined this site after seeing one in a thread.
    I know how tough they are and I've never had this issue with any one of the...
  10. Replies
    25
    Views
    1,646

    Mason will you check how your zippers are sewn...

    Mason will you check how your zippers are sewn in? Do you have one pass or two passes holding them in?
  11. Replies
    25
    Views
    1,646

    Ok so I'm on my third Tech Pac :( Should I move...

    Ok so I'm on my third Tech Pac :(
    Should I move into this new one that has the exact same stitching on the zipper and hope they continue this cycle of warranty nonsense for 4+ years or sell this...
  12. Replies
    54
    Views
    2,743

    The screen is far away That's 20.9 microns not...

    The screen is far away
    That's 20.9 microns not 209 :)
  13. Replies
    54
    Views
    2,743

    How is 3/4" too big when it comes to vacuum?...

    How is 3/4" too big when it comes to vacuum?
    Will see how it works out this week but this vinyl is so much easier to work with than the 1/2" Appion hose I have.
    I might end up going back to my...
  14. Replies
    54
    Views
    2,743

    I tried your idea. This is 3/4" ID and 1"...

    I tried your idea.
    This is 3/4" ID and 1" Sharkbite fittings and clamps from HD
    It collapsed the hose so that's what the wire is for.
    ...
  15. Replies
    9
    Views
    226

    Hey, there are all the contest threads Some...

    Hey, there are all the contest threads
    Some funny posts in there LOL :)
  16. I'm not so sure it's surface tention. In the...

    I'm not so sure it's surface tention. In the video it appears the gas bubbles form at the very bottom.
  17. Replies
    22
    Views
    752

    BluVac tells you when it needs to be cleaned or...

    BluVac tells you when it needs to be cleaned or calibrated.
  18. I have made soda at home but who cares? So how...

    I have made soda at home but who cares?
    So how much N2 per oz can POE hold at equilibrium in a dry condensing unit or replacement compressor that's been through shipping and sitting at the supply...
  19. I took a closer look and the zipper that pulled...

    I took a closer look and the zipper that pulled out and it had less stitching than the other side. Looks like they sew them in with two passes and the one that tore out only had one pass.
  20. I'm going to try what you posted about the cheap...

    I'm going to try what you posted about the cheap vinal hose.
    I think that was a good idea.
    Gonna get some 3/4"
  21. Replies
    22
    Views
    752

    fluctuating up and down on a blank off, a rise to...

    fluctuating up and down on a blank off, a rise to around 2200 and holds or rise to HI Pressure?
    If there is a leak you will rise till the gauge reads HI pressure
    If you hold some mid level there is...
  22. Parker? Don't they sell driers? Hummmm........ :)

    Parker? Don't they sell driers? Hummmm........ :)
  23. I've read that many times. The can't and not...

    I've read that many times.
    The can't and not comes from the same camp that used 1/4" hoses and service manifold for everything. Many old practices are becoming new again to many.
    To answer your...
  24. For those who haven't seen POE degassing here is...

    For those who haven't seen POE degassing here is a look.
    This was after a major initial degassing
    POE will settle down and slowly degas under vacuum alone. From watching oil sight glasses this is...
  25. I looked up what you said and no mention of a...

    I looked up what you said and no mention of a chemical reaction and couldn't find anything with how you described the very last bit of moisture in POE

    Chemical reaction