    In the property sheet of the History Points list...

    In the property sheet of the History Points list there is a slot called "time window" where you can tell it how many hours in the past to display.
  2. Thread: Trane Tracer TU

    by wojami
    Replies
    1
    Views
    476

    Trane Tracer TU

    Anyone know where to buy Trane's Tracer TU software other than the local trane office?
  3. Replies
    5
    Views
    985

    You cannot just swap out controllers without re...

    You cannot just swap out controllers without re assigning the neuron ids in tracer summit. When you see values on the graphic it will still be from the old controller.

    Do you have rover software...
  4. Replies
    26
    Views
    7,625

    There is a new beta ui out that does not use...

    There is a new beta ui out that does not use java. It is alot faster since it caches data but like I said it is beta until after the first of the year or later. It does have several bugs but it...
  5. Replies
    43
    Views
    10,294

    It seems to me if we are talking "Bacnet" that we...

    It seems to me if we are talking "Bacnet" that we already have the "barcode" that you are referring to in MAC addresses/ IP addresses. Each device is already unique, it would be a matter of plotting...
  6. Thread: Tracer SC

    by wojami
    Replies
    8
    Views
    1,315

    I dont not know exactly, I dont think there is a...

    I dont not know exactly, I dont think there is a set number. Alot depends on how loaded up it is devices, programming, graphics. From what I read it says it can store 40 million points with 15 min...
  7. Thread: Tracer SC

    by wojami
    Replies
    8
    Views
    1,315

    Current version of Tracer SC , 5 concurrent...

    Current version of Tracer SC , 5 concurrent users. Tracer ES depends on the version of SQL you have. If SQL Express, 30 concurrent users. If full licensed SQL, 100 concurrent users.
  8. Replies
    5
    Views
    489

    You should only control a point or variable once....

    You should only control a point or variable once. In situations like this I usually use local(*L0 -*L7 or real variables(R0-*R3) . You can use up to four real and 8 local in each program, they only...
  9. Replies
    7
    Views
    1,606

    I don't think it is the controllers that are the...

    I don't think it is the controllers that are the problem. It's the tu software/sc that is extremely slow. If you do a spy to analyze the link it is actually passing info very fast.
  10. Replies
    7
    Views
    1,324

    Shoot me an email and I will send you a file so...

    Shoot me an email and I will send you a file so you wont have to type that in every time. Email is on profile.
  11. Replies
    7
    Views
    1,324

    Sorry, the lon"x" should be whatever number your...

    Sorry, the lon"x" should be whatever number your echelon adapter uses. Mine is 1 but it could be different. It should be the same as whatever lon software you use. If you use rover it will be the...
  12. Replies
    7
    Views
    1,324

    I'm thinking 1.08 or 2.08 off the top of my head...

    I'm thinking 1.08 or 2.08 off the top of my head I will have to look. Mine always did that before, I would open Cmd and point it to the nodeutil.exe file and then -d Lon x to use my echelon adapter....
  13. Replies
    7
    Views
    1,324

    My nodeutil works fine on windows 7 with the...

    My nodeutil works fine on windows 7 with the echelon adapter. Hyperterminal is not included on windows 7. But you can copy the files off of a xp computer and it will work.
  14. Replies
    2
    Views
    494

    I usually get that winsock error when there are...

    I usually get that winsock error when there are duplicate ip addresses.
  15. Replies
    6
    Views
    551

    Go to belimo's website, their product guide as...

    Go to belimo's website, their product guide as alot of useful info. Valves, actuators, as well as wiring diagrams for all the different applications.
  16. Replies
    6
    Views
    1,227

    I have always used bcu config utility, it is...

    I have always used bcu config utility, it is located in the tracer summit bin folder
  17. Replies
    6
    Views
    1,258

    I did write some of the points from a jace, and...

    I did write some of the points from a jace, and it was a KCC unit. But, I would be very hesitant to take a program and have someone just dump it in. A lot of things could have changed and if the...
  18. Replies
    6
    Views
    1,258

    If these are the units I'm thinking of they are...

    If these are the units I'm thinking of they are made and programmed for trane. Everything is setup/controlled from the operator display . Features are turned on/off and set points are changed there...
  19. There is no master user/password since by default...

    There is no master user/password since by default security isn't set up. You will have to get it somehow. I don't know of a back door but their could be one but it might require trane tech support.
  20. Replies
    22
    Views
    3,348

    The drawback to the ES lite/express is the...

    The drawback to the ES lite/express is the memory. You are limited to 4 gb I believe. If you are going to do alot of trending it could be a problem. You are also limited to 5 bcu's/ sc's. Good fit...
  21. Replies
    12
    Views
    2,144

    I have a site site with some ahir handlers with...

    I have a site site with some ahir handlers with chw preheat oa/ra that the pid just locks up periodically and takes hours to days to go back to normal. If they are at version 5.1 you can map a bv...
  22. Replies
    4
    Views
    534

    You can use a bcu to communicate with vav I's....

    You can use a bcu to communicate with vav I's. Not sure what your wanting to communicate with. The bcu has to be at a high enough image and have a high enough service pack to do this.
  23. Replies
    4
    Views
    698

    It seems I am doing it fairly close to the same...

    It seems I am doing it fairly close to the same way. Your fight discharge air control with dx is tough. Its always interesting to see others methods. I have added both on and off delays as well as...
  24. Replies
    12
    Views
    2,144

    Hopefully the adaptive tuning has improved or...

    Hopefully the adaptive tuning has improved or been removed on the FEC controllers. It is anything but adaptive.
  25. Replies
    2
    Views
    469

    I have always had the best luck with modbus...

    I have always had the best luck with modbus registrys by going to the manufacturers site. This si usually open info.
  26. Replies
    4
    Views
    698

    Dx control strategies

    I recently retrofitted a couple of York vav rooftops with 3compressors oa/ra dampers using discharge air control. Curious what strategies everyone else uses in similar applications. Always tough to...
  27. Replies
    22
    Views
    3,348

    Tracer Es version 3 is now out which has alot of...

    Tracer Es version 3 is now out which has alot of improvements but if you are trying to do any type of non trane integration that isn't thru the bcu I would go another route. Tridium is always a solid...
  28. Replies
    13
    Views
    1,702

    Doesn't seem to be doing much adapting

    Doesn't seem to be doing much adapting
  29. Replies
    13
    Views
    1,702

    Love it I actually reset the controller and it...

    Love it

    I actually reset the controller and it started controlling normally. They are not resetting them every day, but this happens frequently. I wish this was the only site I know of that has...
  30. Replies
    13
    Views
    1,702

    Ok thanks for the tips, but I have to play devils...

    Ok thanks for the tips, but I have to play devils advocate here. It seems to me that you shouldn't have to reset it periodically. The customer has basically gold me that they have come out and...
  31. Replies
    13
    Views
    1,702

    JCI FEC Adaptive control

    I have a FEC controller that is taking a fery long time to ramp up. Chilled water valve is taking hours to open up and will not make discharge air setpoint. I am wondering if it due to the adaptive...
  32. Replies
    4
    Views
    749

    Its actually really easy once you figure it out....

    Its actually really easy once you figure it out. I have a "how to" I made with screenshots on how to do this. Shoot me a email and I can send it to you.
  33. Thread: Trane

    by wojami
    Replies
    11
    Views
    1,131

    That is correct, you will not see them in rover. ...

    That is correct, you will not see them in rover. They are actually isolated comm 3 and I believe everything is set on a TCM via dip switches on the board.
  34. Thread: LynxSpring Jace

    by wojami
    Replies
    3
    Views
    746

    Its no different than any other jace in my...

    Its no different than any other jace in my opinion. We have used them many times and I have always used regular workbench. You dont have to have anything proprietary.
  35. Thread: Trane UCM

    by wojami
    Replies
    1
    Views
    897

    If it is comm 5 it will hae a neuron ID, usually...

    If it is comm 5 it will hae a neuron ID, usually has a sticker that has it also. If it is comm4 or below it will have dip switches for setting the address.
  36. Replies
    11
    Views
    1,256

    You have to create a tgp program and use network...

    You have to create a tgp program and use network inputs and outputs to see them. Local binary and analog variables reside in the MP580 only. Example discharge air temp would be written to nvotemp01....
  37. Replies
    6
    Views
    2,051

    The first thing that you need to determine is if...

    The first thing that you need to determine is if the vav boxes are a member or area and Vas. If they are not they will not go to max heat during morning or daytime warmup. It is normal for the rtu...
  38. Thread: niagara ax

    by wojami
    Replies
    1
    Views
    565

    niagara ax

    Whats the best way to tie a jace with a soft jace. I already have some graphics and programming in ths jace but I was thinking the soft jace should be the supervisor. Any ideas?
  39. Replies
    1
    Views
    614

    jace io question

    I have a jace with a io on it I am controlling a ahu. I am having trouble getting my analog outputs to work which I am sure is a scaling problem. Not sure I have them set up correctly.
    I also have...
  40. Replies
    16
    Views
    2,037

    I guess its just different than I am used to. ...

    I guess its just different than I am used to. Typically I have a forced rotate, lead lag enable/disable point, a fail for each pump and rotate based on a time. I actually like the rotate based on...
  41. Replies
    16
    Views
    2,037

    The only thing I wish the leadlagruntime had was...

    The only thing I wish the leadlagruntime had was a forced rotate so you could force it manually.
  42. Replies
    3
    Views
    1,101

    I have done a couple of these and if I were you I...

    I have done a couple of these and if I were you I would give it a year or two. It has some serious bugs that I am not sold are resolved yet. And they just released chiller plant control so I cant...
  43. Replies
    16
    Views
    2,037

    AX Pump Lead/Lag program

    Does anyone have a pump lead/lag program for AX that they could send me?
  44. Replies
    7
    Views
    868

    I could be wrong but if the unit is 10 years old...

    I could be wrong but if the unit is 10 years old it may not accept a comm 5 LCI. It may have to be a comm 4 card. Its possible the RTM could be updated but it would be worth doublechecking before...
  45. Replies
    7
    Views
    1,145

    If your rover is up to date you can now change...

    If your rover is up to date you can now change dsn's in passive mode.
    The latest version is v7.1 sp7.
    It is very dangerous to go in the active mode on a already configured link. I would suggest...
  46. Replies
    15
    Views
    1,517

    If the site has Tracer Summit you could do summit...

    If the site has Tracer Summit you could do summit passthru and access all of the same things without needing the cable to connect. Not as fast but the same thing.
  47. In case anyone wants to know you use sitebook to...

    In case anyone wants to know you use sitebook to create the device and then cms.exe to change the IP information.
  48. Replies
    4
    Views
    1,558

    You will need to use hyperterminal if it is a...

    You will need to use hyperterminal if it is a older varitrac. Set it up as 9600 baud, 8 data bits, parity None, stop bits 1,flwo control Xon/Xoff . You should be able to configure everything this...
  49. Ned to set IP addresses on two York RTUs with bacnet/ip cards

    I need to set up the ip addresses on two units that have bacnet/ip boards on them but I can remember how or what to use. I was thinking it was sitebook or project builder. ANy help?
  50. Replies
    8
    Views
    846

    Thanks alot. I now realize what I was doing...

    Thanks alot. I now realize what I was doing wrong.
Results 1 to 50 of 68
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event