  1. Replies
    5
    Views
    727

    There not cheap but work well. ...

    There not cheap but work well.

    http://www.vansteenburghengr.com/_index.php
  2. Replies
    27
    Views
    3,914

    The hook came with the DigiCools. I used a Dremel...

    The hook came with the DigiCools. I used a Dremel and a small level to get the sensors level. Not sure if the AK case is different or not. I also have several cases that I got from Lockhart years ago...
  3. Replies
    105
    Views
    8,038

    I did the same to the Titans I have. You had...

    I did the same to the Titans I have. You had asked me before about how the JB manifold was working and like I said I have had no problems with it. If Lockhart had a 4 valve out then that is what I...
  4. Replies
    27
    Views
    3,914

    Yes I am and have been working good. I have had...

    Yes I am and have been working good. I have had no issues with any of the valves leaking like gravity above stated.
  5. Replies
    23
    Views
    3,296

    Its actually 37 degrees but I am talking quality...

    Its actually 37 degrees but I am talking quality of the fitting. Any decent hydraulic or fitting supply store or whatever is around you will have those fittings.
  6. Replies
    23
    Views
    3,296

    Not all of those connectors are created equal. Go...

    Not all of those connectors are created equal. Go to a hydraulic supply store and get a set of higher quality fittings. If the ones you have are cheap chinaman made crap fittings which I suspect they...
  7. Thread: bluvac

    by Reeferman
    Replies
    21
    Views
    3,217

    I have never heard Jim Bergmann ever say that.

    I have never heard Jim Bergmann ever say that.
  8. Replies
    13
    Views
    1,675

    Like I said do yourself a favour and take some...

    Like I said do yourself a favour and take some time to go through the threads on all of the digital gauges. You are going to find that the Digi Cool has had issues with the temperature sense wiring...
  9. Replies
    13
    Views
    1,675

    You been on here since 2008 and just asking about...

    You been on here since 2008 and just asking about them now? Do yourself a favour and search through the archives
  10. Thread: Clamp meters

    by Reeferman
    Replies
    12
    Views
    1,665

    Fluke 336,376,381.

    Fluke 336,376,381.
  11. It don't matter which one you use. Be the same as...

    It don't matter which one you use. Be the same as pissing in the Atlantic Ocean as to making any difference.
  12. Replies
    31
    Views
    6,473

    And for those times that a torch can't be used....

    And for those times that a torch can't be used. Works great.

    http://www.theinductor.com/index.php?m=41
  13. http://www.vansteenburghengr.com/_index.php ...

    http://www.vansteenburghengr.com/_index.php

    Not sure if the school budget will allow for it though. Go to product link and see if any will come close. Their units do much more than just a one time...
  14. Replies
    7
    Views
    1,714

    I made this one for my 1100 before Digicool had...

    I made this one for my 1100 before Digicool had any clamps.Heated a 7/8" copper pipe and melted the jaws to conform to it. Glued the sensor on and have been using it since. You need to let the clamp...
  15. Replies
    35
    Views
    6,130

    Have a 2000 and a 4000 both have out lasted...

    Have a 2000 and a 4000 both have out lasted anyother that I have tried. Had to replace valve head and piston cup on them but they have moved a lot of refrigerant.
  16. Replies
    35
    Views
    6,130

    This is the one I use but there are others. ...

    This is the one I use but there are others.

    http://i125.photobucket.com/albums/p45/r404a/DSC02321.jpg
  17. We have a couple of the XLT units and work fine....

    We have a couple of the XLT units and work fine. The largest amounts I remove are 28 to 30 lbs of 404 or 22 from multitemp reefers and takes less than an hour to 10" vacuum. I have a couple of...
  18. Thread: torch set

    by Reeferman
    Replies
    9
    Views
    1,600

    You got a picture of what you did?

    You got a picture of what you did?
  19. Replies
    6
    Views
    1,652

    I believe it was invented by Myron Stein Owner of...

    I believe it was invented by Myron Stein Owner of AirSept for fixing aluminum ac lines that cost big bucks to replace. It works really well as I have used them.
  20. Replies
    2
    Views
    787

    Throw them away and buy new ones. Better yet buy...

    Throw them away and buy new ones. Better yet buy hoses that do not have the ball valves on the end and buy the ball valves separate. That way if you have an issue with the hose or valve you don't...
  21. Replies
    10
    Views
    754

    They have a very good fit and also have o-rings...

    They have a very good fit and also have o-rings that can be replaced if there get loose. We can thank the EPA under the SNAP regulations for all the bull crap that has and is coming to the automotive...
  22. Replies
    10
    Views
    754

    Make sure you get ones with control valves. I...

    Make sure you get ones with control valves. I have tried many brands and the Yellow Jackets such as these are the best I have found. Get the ones that have the 1/4" male flare.
    ...
  23. Replies
    24
    Views
    2,917

    http://www.trutechtools.com/Digi-CoolRSA

    http://www.trutechtools.com/Digi-CoolRSA
  24. Replies
    13
    Views
    2,776

    Expect to pay about three times the price for a...

    Expect to pay about three times the price for a pure sine wave inverter but you will have no more problems. A decent 1000 watt continuous will take about $400.00. Depending on what you want it to do...
  25. Replies
    319
    Views
    25,653

    Now that is #%^*ing funny.

    Now that is #%^*ing funny.
  26. Replies
    17
    Views
    5,384

    You have either 37 or 45 degree flares. I am...

    You have either 37 or 45 degree flares. I am assuming that what they mean by single or double lap is a single or double lipped flare. With the higher pressure of 410 a single flare would probably not...
  27. Replies
    170
    Views
    20,952

    Damn just too quick!!!

    Damn just too quick!!!
  28. Replies
    170
    Views
    20,952

    Damn lover you're just too quick for me.

    Damn lover you're just too quick for me.
  29. Replies
    170
    Views
    20,952

    -Given HVAC-TALKS status as a learning site for...

    -Given HVAC-TALKS status as a learning site for the advancement of further educating the trade of hvac, members can often find themselves in arcane discussions on various subjects.

    - This whole...
  30. Replies
    170
    Views
    20,952

    Please give an example in a sentence of the...

    Please give an example in a sentence of the context you wish to express. I eagerly await.
  31. Replies
    170
    Views
    20,952

    Quote: Originally Posted by hvaclover...

    Quote:
    Originally Posted by hvaclover http://hvac-talk.com/vbb/images/buttons/viewpost.gif
    Look up arcana and then you will understand why you won't get it.


    What do tarot cards have to do...
  32. Replies
    170
    Views
    20,952

    What do tarot cards have to do with having a...

    What do tarot cards have to do with having a micron gauge in a set of digital manifolds??
  33. Replies
    170
    Views
    20,952

    What won't I get?

    What won't I get?
  34. Replies
    170
    Views
    20,952

    So what is the value? Just askin.

    So what is the value? Just askin.
  35. Replies
    170
    Views
    20,952

    So what's the point of having one in a digital...

    So what's the point of having one in a digital manifold then?
  36. Replies
    319
    Views
    25,653

    Be careful there iceman as you may have yours...

    Be careful there iceman as you may have yours deleted like mine did:censored: good grieve
  37. Replies
    36
    Views
    2,998

    A gay sponge that lives in the sea. ...

    A gay sponge that lives in the sea.

    http://i125.photobucket.com/albums/p45/r404a/cf6c5b4b.jpg

    http://i125.photobucket.com/albums/p45/r404a/911a0db1.jpg
  38. Replies
    6
    Views
    1,170

    Any hydraulic hose shop will have them and should...

    Any hydraulic hose shop will have them and should have different styles of them. Some will have the smaller ones and some will have the larger ones.
    You can also use straight fittings and do this....
  39. Replies
    55
    Views
    4,297

    Those are a bastardized version.

    Those are a bastardized version.
  40. Replies
    3
    Views
    743

    It has no effect on then what so ever. I have...

    It has no effect on then what so ever. I have several sets and one is used for mobile a/c only which pretty much every oem uses dye in their vehicles. Also the slight hg and psi readings like you had...
  41. Replies
    6
    Views
    916

    Hmm I don't know what to say about that as I have...

    Hmm I don't know what to say about that as I have not seen this. I have several other Fluke meters and scopes and have not noticed any of this on them.
  42. Replies
    6
    Views
    916

    I have had a 179 for several years. Not sure what...

    I have had a 179 for several years. Not sure what you mean by the display as I have never had a Fieldpiece and probably never will. The 179 has been dropped,in rain,snow,mud,oil,grease and never had...
  43. Replies
    14
    Views
    2,742

    See if it fits on to either the low or high side...

    See if it fits on to either the low or high side of a auto 134a system service valve port.
  44. Replies
    14
    Views
    2,742

    That service valve sure looks like a Eaton big...

    That service valve sure looks like a Eaton big bore 134a a\c service valve that Freightliner uses. I can't see it that well in the picture but if it is then you can buy the valve core tool for it.
  45. Replies
    5
    Views
    1,147

    If you are going to stick with analogs I really...

    If you are going to stick with analogs I really suggest you replace them if they have been knocked around like that.
  46. Replies
    27
    Views
    3,914

    So far these are working much better than I...

    So far these are working much better than I thought they would. Had to adjust charge on a unit and the control for refrigerant is really good. Never thought I would say this about a JB manifold. Time...
  47. Replies
    27
    Views
    3,914

    On the other case.

    On the other case.
  48. Replies
    27
    Views
    3,914

    Couple of things with this manifold that are...

    Couple of things with this manifold that are going to be an issue. The hose holders that seem to be a good idea I am not sure if they are going to be able to take the weight of the hoses I use. Also...
  49. Replies
    27
    Views
    3,914

    I won't know until I go back to work and hook it...

    I won't know until I go back to work and hook it up to a reefer.
  50. Replies
    27
    Views
    3,914

    Just had to move the sensors with a little...

    Just had to move the sensors with a little modification of the rear case.