  1. I use a pan under the unit with a cut-off switch...

    I use a pan under the unit with a cut-off switch too. It sounds like your drain may have been clogged from the older unit and not the new one. I've had this happen once before. Changed out the...
  2. Replies
    6
    Views
    589

    The louvered cabinet by far is better. It...

    The louvered cabinet by far is better. It protects the coil from anything. If the cost is close, that should be the deciding factor. JMO
  3. Replies
    9
    Views
    1,284

    Go with the Trane. You will have less problems...

    Go with the Trane. You will have less problems and it will last a lot longer for you too.
  4. Replies
    6
    Views
    851

    Sorry to inform you sir (or madam) but if your...

    Sorry to inform you sir (or madam) but if your Gooooman unit hasn't been serviced in a few years, now is the perfect time. I have found that most if not all Goooman package unit heat exchangers...
  5. Replies
    86
    Views
    9,132

    Just be quick about it!!!:)

    Just be quick about it!!!:)
  6. Replies
    16
    Views
    2,875

    It appears that the spiral duct is not reduced...

    It appears that the spiral duct is not reduced after the registers. This will cause low static and make the supply air extremely slow, cold and cause unwanted condensation.

    It's hard to tell...
  7. Thread: Capacitors

    by superd77
    Replies
    10
    Views
    980

    Just like checking a 9v battery. If it don't...

    Just like checking a 9v battery. If it don't tingle a little it's bad!!
  8. Replies
    12
    Views
    881

    I'm thinking he's restricted at the new drier. ...

    I'm thinking he's restricted at the new drier. Not sure. He's going back this afternoon, maybe he left something out.
  9. Replies
    12
    Views
    881

    Do you think a bi-flow would blow the desiccant...

    Do you think a bi-flow would blow the desiccant out?? I think they have screens to prevent just that??? IDK??
  10. Replies
    18
    Views
    1,929

    The extra water in the pan won't go away. The...

    The extra water in the pan won't go away. The pan is designed to hold some water even after the unit shuts off.

    First things first, open all the vents. Just cause you close some don't mean...
  11. Replies
    12
    Views
    881

    He said he put the filter in the discharge line. ...

    He said he put the filter in the discharge line. About a foot away from the compressor. Mufflers in the discharge is what you've been seeing. Not driers!
  12. Replies
    12
    Views
    881

    He definitely said discharge line.

    He definitely said discharge line.
  13. Replies
    12
    Views
    881

    Freezing package unit

    Goodman 5 ton package str-8 air. My colleague changed the compressor out. (pins broke off in molded plug). He said he put a drier in the " discharge" line between the coil and compressor. Now he...
  14. Replies
    18
    Views
    1,929

    The drain needs to have a ptrap installed. The...

    The drain needs to have a ptrap installed. The negative pressure on the drain will cause the air handler to hold water in and when it shuts off the water will rush down the drain. Sometimes...
  15. Replies
    5
    Views
    758

    Love my sman3 gauges!!!

    Love my sman3 gauges!!!
  16. Replies
    35
    Views
    3,806

    Milwaukee is my choice. The M12 line is awesome!...

    Milwaukee is my choice. The M12 line is awesome! A charged battery lasts for a couple weeks and the drill itself has a battery life display. Makita don't have that.
  17. Thread: R-410 issues?

    by superd77
    Replies
    10
    Views
    852

    So you got your universal EPA card.... And no one...

    So you got your universal EPA card.... And no one there or around you mentioned anything about 410-22 conversion??? Sorry, but this trade can't be taught from the yard sale. You need actual training...
  18. Replies
    17
    Views
    2,159

    So you must be an engineer? Lol

    So you must be an engineer? Lol
  19. Replies
    17
    Views
    2,159

    So why did your neighbor put in the last one?? ...

    So why did your neighbor put in the last one??

    Universal tech in what??
  20. Replies
    13
    Views
    2,039

    Yes, all of the units with small slabs in them...

    Yes, all of the units with small slabs in them have been leaking. And I haven't been able to get any labor or refer from them either.
  21. Replies
    13
    Views
    2,039

    Yep!

    Yep!
  22. Replies
    9
    Views
    707

    I can see the unit short cycling at 50 degrees. ...

    I can see the unit short cycling at 50 degrees. If its 50 in the house, then that's the temp of the air blowing over the heat exchanger. This low of a temp is likely to cool the chamber down...
  23. A zone system would work fine. When only one zone...

    A zone system would work fine. When only one zone calls the excess air recirculates through the bypass. This will cause the supply air to drop even lower and help the one zone to satisfy faster. ...
  24. Replies
    44
    Views
    3,297

    Ditto!!! The sman3 is my first set. No...

    Ditto!!! The sman3 is my first set. No complaints.....yet. :)
  25. Thread: It's A Trap!!

    by superd77
    Replies
    27
    Views
    2,668

    They are used to evaporate condensate since they...

    They are used to evaporate condensate since they usually don't have open drains
Results 1 to 25 of 500