Search:

Type: Posts; User: vaultein

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    17
    Views
    493

    Compact Laptop or Tablet

    Anyone have experience using compact laptops or tablets for service work?
    Needs to be able to handle any program and interface, including virtual machine for the older stuff.

    My laptop is great...
  2. Iv'e seen then get brittle in hot area's. What I...

    Iv'e seen then get brittle in hot area's. What I meant was, they can take a beating. Iv'e seen them get soaked and come back to life.
  3. Replies
    3
    Views
    281

    Had the same issue. Replaced the timezone .jar...

    Had the same issue. Replaced the timezone .jar file from 6.1 in the "lib" folder. solved the issue.
  4. That was my original thought, but these are old...

    That was my original thought, but these are old units and not practical to do this in a cost effective way.
  5. Thank you. Existing units and controls, so...

    Thank you.
    Existing units and controls, so replacing valves won't work.
    Is there anything other that a DPT that I can use?
  6. Chilled Water Coil Performance Monitoring Help

    What would be the best way to monitor the performance of a chilled water coil on a AHU?
  7. The DX9100 is a workhorse and does not lockup,...

    The DX9100 is a workhorse and does not lockup, flake or die, for the most part.
    Its strengths, in my opinion is:
    Reliable. Once set up properly, you would not have to touch it again.
    Some people...
  8. Replies
    0
    Views
    176

    Wireless Humidistat

    Hi,

    Does anyone know of a wireless humidistat??

    Thanks
  9. Replies
    6
    Views
    434

    Good idea, I'll give that a shot when on site...

    Good idea, I'll give that a shot when on site next.

    Thanks
  10. Thread: Smart Watches

    by vaultein
    Replies
    22
    Views
    1,100

    With the flip of your wrist, you can decide to...

    With the flip of your wrist, you can decide to pickup or not. And if your hands are occupied, you can answer on the watch, using the built in mic/speaker.

    The screen is surprisingly easy to view...
  11. Replies
    6
    Views
    434

    The P= -9999 and the I= .8 The highest I can go...

    The P= -9999 and the I= .8
    The highest I can go without downloading is +/-9999, through DX Commissioning Tool.
    The highest CFM would be around 15,000.
  12. Thread: Smart Watches

    by vaultein
    Replies
    22
    Views
    1,100

    I have the Apple watch. I love that I don't have...

    I have the Apple watch. I love that I don't have to take out my phone (for the most part) while working in the field. I can review and answer emails, texts and answer the phone, if need be. It is a...
  13. Replies
    6
    Views
    434

    DX-9100 PID Air Flow Tuning

    Hi,

    I am trying to tune a PID on a DX-9100 that has a CFM setpoint of 11,000 and can't seem to nail it.
    Does anyone have ballpark figures for the PB and IT? I managed to get the hunting down to...
  14. Replies
    17
    Views
    1,458

    I've seen where they are like a 1/4 the size,...

    I've seen where they are like a 1/4 the size, that caused weird comm issues.
  15. Replies
    8
    Views
    569

    What are you controlling with a 0-10VAC signal?

    What are you controlling with a 0-10VAC signal?
  16. Replies
    2
    Views
    380

    FX - Graphics Slide-Show

    Happy Friday,

    Is there a way to set up a graphics page that can switch pages automatically?
    Meaning, lets say I put up a big screen and want all my units to be displayed, one at a time, for 15...
  17. Replies
    17
    Views
    1,458

    Did you recently upgrade the .Jar files? I...

    Did you recently upgrade the .Jar files?

    I have found when updating, some .Jar files get corrupted and need to be added manually.
    The way to check is, go into your "File Transfer Client", open up...
  18. Just a thought on two AO's for one actuator......

    Just a thought on two AO's for one actuator...
    You can wire one of the AO's to an AI, Isolate the 2 AO's via a relay.
    If the AI doesn't match the AO, make the relay and switch the signals.

    And...
  19. I have not used the AX version, but using...

    I have not used the AX version, but using Workbench, it's relatively easy.
    -Add a device to the N2 network.
    -In the Nav drop down menu (top right), go to Import Manager.
    -Double click on the...
  20. Replies
    11
    Views
    855

    Electronic Work Orders

    Managers/Techs,

    What do you use for electronic work orders?
    Our company is looking to get rid of the paper work orders and go digital..
    Looking for ideas on devices and software.

    Thanks,
  21. Replies
    18
    Views
    1,401

    AX should work the same as FX, in terms of...

    AX should work the same as FX, in terms of integrating a DX9100.
    I never had an issue commanding DO's.
    One note though, if you override a DO through the Jace, you will not be able to override it...
  22. Replies
    9
    Views
    790

    Is there any data sheet on how to determine the...

    Is there any data sheet on how to determine the type of sensing element it is?
  23. Replies
    13
    Views
    914

    JCI version of Viconics....

    JCI version of Viconics.
    http://www.industrialcontrolsonline.com/node/2773
  24. Replies
    0
    Views
    279

    Rickard MCU2 Help

    Hi,

    Has anyone worked with the Rickard MCU2 Bacnet integrator?
    where do I get a hold of the MLM Tools?

    Thanks
  25. Exactly what I was looking for. Thank you!

    Exactly what I was looking for.
    Thank you!
  26. Configuring multiple Slots/Flags at once.

    Hi,

    I remember coming across this before, but I cannot find it for the life of mine.

    How do you batch edit slots on multiple points.
    For example, ZN-SP - Remove "Override, Auto" flags on...
  27. Replies
    25
    Views
    6,541

    Thanks, Kontrol. I was able to discover the...

    Thanks, Kontrol.
    I was able to discover the Bacnet/MSTP to IP router. However, I could not figure out how to discover the points on the PCG, on the other end of the router. Only one point that...
  28. Replies
    25
    Views
    6,541

    Reading the above had me thinking... Would it...

    Reading the above had me thinking...

    Would it be possible to go from a Bacnet controller, thru a BBMD, directly to Niagara Workbench Supervisor, using Bacnet/IP? There by eliminating the need for...
  29. Replies
    4
    Views
    389

    On top of what s2sam said... What Bacnet...

    On top of what s2sam said...
    What Bacnet controllers are you using?
  30. Replies
    9
    Views
    680

    You're better off installing batteries. Don't...

    You're better off installing batteries. Don't know how much surge protector would help.
  31. Replies
    9
    Views
    680

    I do not believe there was an issue with the...

    I do not believe there was an issue with the batteries.
    They built the FXx0E with on board ram that was supposed to eliminate the need for a battery.
    However, that idea was proven to be a real...
  32. Replies
    9
    Views
    680

    Ok. Yes they are correct. There is an issue with...

    Ok.
    Yes they are correct. There is an issue with the FX60E's that were sent without batteries.
    That's why they send them with batteries now.

    Whoops...
  33. Replies
    18
    Views
    1,232

    Using a Diode, you will cut the 24VAC to 12VDC,...

    Using a Diode, you will cut the 24VAC to 12VDC, unless it is 24VDC already.
  34. Replies
    2
    Views
    455

    Yes. Thank you!

    Yes.
    Thank you!
  35. Replies
    9
    Views
    680

    Dumb question; have you tried resetting the FX60?...

    Dumb question; have you tried resetting the FX60? you may need to disconnect the battery to force it to reset.
  36. Replies
    2
    Views
    455

    UNT Network Zone Temp

    Hi,

    Using Workbench, I am trying to share the zone temperature from one controller to another.
    Is there a way to override the AI or make some sort of network point??

    Thanks
  37. Replies
    8
    Views
    859

    Don't know exactly what you refer to as the...

    Don't know exactly what you refer to as the "link".

    Here are the general guidelines for an N2 network.

    Maximum devices per comm port = 50 devices.
    Maximum wire length = 5000 Ft.

    The Jace...
  38. Replies
    3
    Views
    674

    VPN

    VPN
  39. Replies
    14
    Views
    1,424

    I'm using VMWare. Works great.

    I'm using VMWare. Works great.
  40. Replies
    14
    Views
    1,424

    Oh ok. I just had to upgrade my laptop to...

    Oh ok.
    I just had to upgrade my laptop to Windows 7 due to the latest release of PCT. Had to install the XP virtual machine to run all my legacy software... it is a real pain to get all the comm...
  41. Replies
    14
    Views
    1,424

    I have both and found that the BASRTP-B is...

    I have both and found that the BASRTP-B is substantially slower than the Bluetooth router.
    If you are having issues with your Bluetooth on your computer, I suggest get an external USB Bluetooth...
  42. Replies
    18
    Views
    3,802

    Are you looking to log in to a Jace or a server...

    Are you looking to log in to a Jace or a server station on a computer?
  43. Replies
    13
    Views
    1,484

    One more note I may add. I have had sites where...

    One more note I may add. I have had sites where the loading bar got stuck. The way I got around it was by deleting the "Niagara" folder from your user folder (C:/Users/(your user name)/Niagara.
    this...
  44. Replies
    14
    Views
    2,312

    I ran into a job where they ran Lon wire for N2,...

    I ran into a job where they ran Lon wire for N2, and it works, somewhat.
    Meaning, it communicates okay, with minor glitches. We are sharing OA temp on it and it messes up the control sequence when...
  45. Replies
    33
    Views
    4,597

    Being the "magician" in the eyes of the costumer....

    Being the "magician" in the eyes of the costumer. At least in service, when you make it all work...
  46. Replies
    7
    Views
    815

    As per spec, I used a RS-232 to RS-245 converter....

    As per spec, I used a RS-232 to RS-245 converter. It sits on a separate bus then the boilers.
  47. Replies
    7
    Views
    815

    Thanks for your reply. I was able to send a...

    Thanks for your reply.
    I was able to send a ping to the ACS, however it did not reply.
    The question I have now is that the ACS is a master and controls two boilers. The jace is set up as a master...
  48. Replies
    7
    Views
    815

    Configuring Aerco Modbus on a Jace.

    I am trying to interface with a Aerco ACS Boiler control panel to a FX30, using Modbus.
    Does anyone have a cutsheet or can step me thru on how to set up the controller perameters in workbench.
    ...
  49. Replies
    16
    Views
    2,366

    Where I am, the techs are union. Jci here is...

    Where I am, the techs are union. Jci here is union as well. Other then that most are not. It became to expensive to be union.
  50. Replies
    12
    Views
    1,084

    This is great! Thank you! Question though, would...

    This is great! Thank you!
    Question though, would this effect a point that has a schedule linked to it? or is this strictly on a "click" override?
Results 1 to 50 of 131
Page 1 of 3 1 2 3