  1. Replies
    19
    Views
    1,305

    If your wife is unhappy then is is an urgent...

    If your wife is unhappy then is is an urgent situation. Call and pay for a second opinion. The price of the service call is a small price to pay to bring harmony back into your house;)
  2. Replies
    11
    Views
    860

    Nice

    Nice
  3. Replies
    11
    Views
    860

    Call your contractor and ask him these questions....

    Call your contractor and ask him these questions. Where do yo live that you only need 5 kw of aux. heat?
  4. Replies
    42
    Views
    4,399

    I use the Testo one. I have no complaints with...

    I use the Testo one. I have no complaints with it. I dont remember how much it was I bought it at Johnstone. It has found many bad heat exchangers the best part is that you can easily show the...
  5. Replies
    11
    Views
    866

    Most likely 1 30 amp is the heat pump. the other...

    Most likely 1 30 amp is the heat pump. the other 2 30 is 1 element the 60 2 elements, blower and controls. man I hope I'm not giving away any secret info and they come and take away my birthday.
  6. Replies
    37
    Views
    7,611

    Yes they are changing it to 134a which qualifies...

    Yes they are changing it to 134a which qualifies it as a reformulation so there is no more generics.(well at least for another 3 years)
  7. Replies
    37
    Views
    7,611

    I huff it daily. The propellant in asthma...

    I huff it daily. The propellant in asthma inhalers is refrigerant look on the label dichlorodifluoromethane.
  8. Replies
    4
    Views
    1,683

    Moving the blower up to "Full Blast" will not...

    Moving the blower up to "Full Blast" will not solve anything with your cold room upstairs. Let me guess you want to have the furnace blow real hard and shut off a bunch of the registers. Maybe that...
  9. Replies
    11
    Views
    3,382

    Well if its built like the old GE's it very well...

    Well if its built like the old GE's it very well could make it that 30 years. I just changed out a working 31 y.o. GE heat pump this week.
  10. Replies
    4
    Views
    1,555

    Variable speed motors

    What Meter/analyzer are you using to diagnose Variable speed motors?
  11. Replies
    6
    Views
    518

    That would be 54 not 57. Im not getting down on...

    That would be 54 not 57. Im not getting down on the Messiah just thought it was funny.
  12. Replies
    6
    Views
    518

    How many states?

    I thought this was funny

    http://www.reuters.com/news/video?videoId=82127
  13. As designed 70%, what it is running at now ?...

    As designed 70%, what it is running at now ? maybe 60%
    as for a quote call out some local contractors in your area.
  14. .

    .
  15. Replies
    28
    Views
    3,839

    I would have said the ductwork oil canning, but...

    I would have said the ductwork oil canning, but you say its not blower related. Time to call out a pro.
  16. What info do you want? correct model#...

    What info do you want? correct model# BLU108F936B1. input:108,000 btus, Blower 3 tons. it's about 23 years old and probably ready to be replaced(yesterday).
  17. Thread: On Call

    by buttwheat
    Replies
    32
    Views
    3,339

    Please keep them coming. My boss has started to...

    Please keep them coming. My boss has started to whine about paying a min. of 2 hrs on a call out, So I need so ammo to come back at him on what other company's do.:)
  18. Thread: On Call

    by buttwheat
    Replies
    32
    Views
    3,339

    On Call

    So how does your company compensate you for being on call?
    My company does not pay you any extra for being on call. They do pay a min. of 2 hours if I get called out. But no on call bonus or...
  19. Replies
    17
    Views
    1,638

    With the IAQ stat and outdoor sensor you will not...

    With the IAQ stat and outdoor sensor you will not need an antique duel fuel kit.
    Any competent technician can easily hook this up for you.
  20. Replies
    14
    Views
    2,040

    and also the XL14 is no longer produced.

    and also the XL14 is no longer produced.
  21. Replies
    14
    Views
    2,040

    Just installed one last thursday. the new XR14 c...

    Just installed one last thursday. the new XR14 c model not the old a model.
    Either it was a VS or it was so under powered it took a while to get up to speed.
  22. Replies
    14
    Views
    2,040

    Yes no more 2 speed motors they are variable...

    Yes no more 2 speed motors they are variable speed now on the 14 seer units.
  23. Replies
    7
    Views
    2,363

    Unless you weight it in there is no reliable way...

    Unless you weight it in there is no reliable way to charge in cold weather. Get it close and come back when it is over 65 out.
  24. Replies
    21
    Views
    2,435

    The fist sound you hear is the inducer, the...

    The fist sound you hear is the inducer, the dragon clearing his throat is the burners. You don't hear that after the blower kicks on is because the blower drowns out the burner sound. Going to a 90%...
  25. Replies
    8
    Views
    770

    X2 I still work on alot of 30+ year old GE's...

    X2 I still work on alot of 30+ year old GE's tuff old units
  26. Replies
    3
    Views
    580

    What he is telling you is true, but that doesn't...

    What he is telling you is true, but that doesn't mean its correct.
  27. No you dont have to change the heat exchanger....

    No you dont have to change the heat exchanger. Pretty easy for a pro to do. pretty easy for a home owner to blow up his house to save a couple of bucks.
  28. Lining it cuts down on noise and makes the duct...

    Lining it cuts down on noise and makes the duct smaller in air volume
  29. Replies
    84
    Views
    5,819

    I hope the internet can come and repair it under...

    I hope the internet can come and repair it under warranty when it breaks.
  30. Replies
    9
    Views
    669

    Older houses where all like that. with that set...

    Older houses where all like that. with that set up it tends to feel drafty with all the heat on the interior walls and all the heat loss on the outside walls. Does your house feel drafty? if not...
  31. Thread: Old Furnace

    by buttwheat
    Replies
    10
    Views
    663

    When was the last time you had a pressure test on...

    When was the last time you had a pressure test on the heat exchanger? It may be time for that new unit now.
  32. Replies
    51
    Views
    3,633

    Should be a minimal amount. Its a Trane and...

    Should be a minimal amount. Its a Trane and should be able to pump down 95% of the refrigerant.
  33. Replies
    10
    Views
    938

    Have you tried the Lenox snipes?

    Have you tried the Lenox snipes?
  34. Replies
    52
    Views
    12,591

    I had a whole line set that looked like that....

    I had a whole line set that looked like that. Another company called me out, No a/c and they just installed 2 days ago. Guess what it had no refrigerant in it. I ripped out the whole line set and...
  35. Replies
    341
    Views
    43,678

    The only drawback I see with the union is that....

    The only drawback I see with the union is that. That dumbass lazy ass guy that you are working with is getting paid the same as you. Pay is based on your experience not your performance. Well I guess...
  36. Thread: Test

    by buttwheat
    Replies
    2
    Views
    627

    What did you say?

    What did you say?
  37. Replies
    25
    Views
    4,229

    Agreed most likely an electrical issue like to...

    Agreed most likely an electrical issue like to small of a circuit ran to heatpump.
  38. Replies
    37
    Views
    5,286

    Nice I had no idea you could do that.

    Nice I had no idea you could do that.
  39. yes you should be ok with the Honeywell.

    yes you should be ok with the Honeywell.
  40. Replies
    20
    Views
    2,629

    Wow great its fixed. Bearings are a far cry away...

    Wow great its fixed. Bearings are a far cry away from controls.
  41. Replies
    8
    Views
    1,346

    That control has no clue if the ignitor works or...

    That control has no clue if the ignitor works or not, Yes it will open the gas valve but will shut down the gas valve in a couple of seconds if no flame is present. If Im thinking of the correct...
  42. Replies
    10
    Views
    1,129

    Could be a lot of different things effecting it....

    Could be a lot of different things effecting it. Have a professional come take a look at it because it is really hard to tell from here whats wrong.
  43. Replies
    14
    Views
    1,099

    I once watched a video (back in the 80s) put out...

    I once watched a video (back in the 80s) put out by GE about the effects that start capacitors have on motor windings. Ever since then I have been hesitant to use them. except when a non bleed txv...
  44. Replies
    20
    Views
    2,629

    Well it used to be a UEM according to the model...

    Well it used to be a UEM according to the model number. may have been rewired. good luck
  45. Replies
    20
    Views
    2,629

    Have your landloard make sure the tech that comes...

    Have your landloard make sure the tech that comes out has Wesco UEM experience. Most people dont under stand that it is a 24 volt DC control system.
  46. If it is a trane XL1200 heatpump from the late...

    If it is a trane XL1200 heatpump from the late 80s or early 90s and 2 1/2 - 4 ton with an Alco ( blue one) valve it's the valve hanging up. They had a lot of problems with that.
  47. Replies
    20
    Views
    2,629

    What reset button? The one by all the thermostat...

    What reset button? The one by all the thermostat wire connections? that would tell me that the blower motor didn't start or stopped when it shouldn't have. you said you had the blower motor replaced....
  48. Replies
    25
    Views
    2,444

    They do now available at your favorite home...

    They do now available at your favorite home improvement store :mad: for cheaper than I sell the Honeywell for.
    To the Op if you have any concern about ozone its a great idea.
  49. Replies
    20
    Views
    2,629

    If it is the fan switch that turns on and off the...

    If it is the fan switch that turns on and off the blower motor by temperature they don't make a direct replacement anymore. The one in your furnace has a 24 volt DC. heater in it the replacement will...
  50. Replies
    30
    Views
    1,576

    If a 90% is running at 67% the exhaust temps. are...

    If a 90% is running at 67% the exhaust temps. are going to be a little more then slightly elevated. it would turn the pvc in to a limp noodle.