Search:

Type: Posts; User: VintageStefurak

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    43
    Views
    1,835

    The liquid line wasn't hot. I make it a habit of...

    The liquid line wasn't hot. I make it a habit of touching the lines so I remember..

    I didn't expect this to go three pages. A lot of information that I will apply to my next job. Also the Nitro...
  2. Replies
    43
    Views
    1,835

    Return and the plenum.

    Return and the plenum.
  3. Replies
    43
    Views
    1,835

    I'd get fired on the spot lol. I gotta crash like...

    I'd get fired on the spot lol. I gotta crash like y'all should too!
  4. Makes sense. Probably lot less water going down...

    Makes sense. Probably lot less water going down the condensate drain too lol

    I guess you install an accessory like a dehumidifier with a higher seer rating?
  5. Not an expert but efficiency means less...

    Not an expert but efficiency means less electricity costs. The units will run less times.
  6. Replies
    43
    Views
    1,835

    Bazooka They sent me to a lot of fin jobs out...

    Bazooka

    They sent me to a lot of fin jobs out of trade school lol. It's a Rheem and the fins are perfect. If it was a unit with a filmsy "fence" around it. It gets destroyed by the hail. Bunch of...
  7. Replies
    43
    Views
    1,835

    hvacrmedic. You are right.

    hvacrmedic. You are right.
  8. Replies
    43
    Views
    1,835

    I did open up the evaporator coil. Looked Ok to...

    I did open up the evaporator coil. Looked Ok to me. I didn't take it out tho. Because that's an other hour brazing it back in.
  9. Replies
    43
    Views
    1,835

    The Condenser fan blew in the right direction. It...

    The Condenser fan blew in the right direction. It was obvious as you can feel it. It was cool when I stood by it. When I got out of the shade I immediately started sweating like a pig lol
  10. Replies
    43
    Views
    1,835

    Yes, that's easy to tell bro. It was spinning in...

    Yes, that's easy to tell bro. It was spinning in the right direction. It was cool when I was standing by it.. Going out of the shade and I was sweating like a mofo.
  11. Replies
    43
    Views
    1,835

    I think he don't mind it failing so we get a new...

    I think he don't mind it failing so we get a new install?
  12. Replies
    43
    Views
    1,835

    I do have a fluke that can take Temps but I left...

    I do have a fluke that can take Temps but I left it in my personal truck truck thinking I I almost never use it. It's more weldy than the clamp on. I'll bring it around every time from now on.

    I...
  13. Replies
    43
    Views
    1,835

    I said that I cleaned the coils and the fan was...

    I said that I cleaned the coils and the fan was blowing very strongly through the vents and at the outdoor coil. That's isn't the problem.
  14. Replies
    43
    Views
    1,835

    We're only running two techs. Me being one LOL...

    We're only running two techs. Me being one LOL The other is a 20 yr veteran. Couldn't tell me the problem. The owner is an instructor at a trade school where he hired me from. He said that at this...
  15. Replies
    43
    Views
    1,835

    Unit running 400 head pressure

    I have been doing installs for a bit now. Just starting to do some service calls.
    I had a call on Monday for a customer complaing that the house wouldn't get below 74 degrees.
    The Suction...
  16. Replies
    18
    Views
    884

    Floated the idea to the boss. Resounding No.

    Floated the idea to the boss. Resounding No.
  17. Replies
    6
    Views
    290

    I will get back there and get the appropriate...

    I will get back there and get the appropriate info. Clearly this is a defrosting issue. What's the best way to fix the unit without losing the items in the fridge/Freezer The client is on government...
  18. Replies
    6
    Views
    290

    The weird thing is that I didn't see a defrost...

    The weird thing is that I didn't see a defrost drain going out? I usually work on mostly res/comm units and as you all know we have condensations drain going out. But not with this fridge or is that...
  19. Replies
    6
    Views
    290

    Fridge not cooling

    I got a call about a charity work on a fridge. (Free work for a mentally disabled individual in a home). I've never worked on appliances but I understand how it works obviously. The access panel for...
  20. True story!

    True story!
  21. Replies
    225
    Views
    46,675

    Sticky: Poll: Rheem/Rudd

    Rheem/Rudd
  22. Replies
    13
    Views
    701

    I'm being told by my employer that it would be...

    I'm being told by my employer that it would be preferable to have separate gages for 22 and 410. I had an extra gage and I'm just going to go ahead and do what he says. Personally, I think one is...
  23. Replies
    7
    Views
    1,094

    I don't know if that's allowed on the forum? *I...

    I don't know if that's allowed on the forum? *I hope not* What's your contact information? I can be reached at Stefurak4@gmail.com I have a resume readily available.
  24. Replies
    7
    Views
    1,094

    Thank you, Sir. I will be applying.

    Thank you, Sir. I will be applying.
  25. Replies
    7
    Views
    1,094

    Fresh out of trade school

    I just graduated from a trade school with A.O.S degrees in HVAC and Building Maintenance. I've only had the pleasure of working with extremely small heating/cooling company on a part time basis for...