  1. Tech Support # Refrigeration Specialties

    Anyone have a contact person and telephone number for tech support? I have a question about an old industrial style hot gas bypass valve on an air conditioning system. If I could figure out how to...
  2. Replies
    2
    Views
    296

    That's great thank you

    That's great thank you
  3. Replies
    2
    Views
    296

    Refrigerant Pipe Sizing Software

    Is there a good, reliable, refrigerant pipe sizing software program out there?
  4. Replies
    0
    Views
    231

    Rooftop HVAC Unit Damper Retrofit

    Does anyone have experience retrofitting packaged HVAC unit standard dampers to low-leakage dampers? I've attached a picture of the unit, and I'm looking to install Tamco 9000 to replace existing...
  5. Replies
    2
    Views
    362

    Thanks very much

    Thanks very much
  6. Replies
    2
    Views
    362

    Flexible Venting Option 9"?

    Anyone aware of a flexible liner in 9"? Looking to vent Lochinvar FBN2500 through existing chimney.
    Thanks,
  7. Replies
    33
    Views
    3,441

    Insurance job

    Insurance job
  8. Yes, headmaster working fine.

    Yes, headmaster working fine.
  9. Not a restaurant, outdoor box in Eastern Canada...

    Not a restaurant, outdoor box in Eastern Canada so it's a pretty cold climate this time of year. I was having the issue in the dead of winter as well when RH is at it's lowest....
  10. The termination sensor is in the space that's...

    The termination sensor is in the space that's icing up (front) it's a klixon type that is mounted to the cabinet with the sensor sticking out into the space between fans and front of coil - where can...
  11. I will check out all door seals as well however...

    I will check out all door seals as well however this problem has been happening in the winter (now) which in Canada, the RH is low and humidity/frost is usually not an issue this time of year...
    ...
  12. I have checked the drain line heater, and yes it...

    I have checked the drain line heater, and yes it is trapped, no ice or water accumulating in the pan, seems to be clearing nicely.

    I will check for leakages in the in the cabinet, a local...
  13. have you had to move defrost termination from...

    have you had to move defrost termination from it's OEM location before? (because this is a new coil)
  14. Evaporator Coil Frosting Around Front Behind Fans

    I have an evaporator coil that is frosting up around the front of the coil in behind the fans. It is frosting up bad, thick frost that builds up in behind the fans all the way across. It's a small...
  15. Replies
    32
    Views
    4,178

    huh?

    huh?
  16. Replies
    32
    Views
    4,178

    slctech: thanks for the post, very interesting.

    slctech: thanks for the post, very interesting.
  17. Replies
    32
    Views
    4,178

    I could send you a picture of the nameplate, it...

    I could send you a picture of the nameplate, it definitely reads 407c
  18. Replies
    32
    Views
    4,178

    Must charge 407c as a liquid.

    Must charge 407c as a liquid.
  19. Replies
    32
    Views
    4,178

    yes i have, the nameplate says 407c

    yes i have, the nameplate says 407c
  20. Replies
    32
    Views
    4,178

    i didn't take heat measurements on all circuits,...

    i didn't take heat measurements on all circuits, but the one i checked had over 40 degrees of subcooling and 30 degrees of compressor superheat. the head pressure was high when these measurements...
  21. Replies
    32
    Views
    4,178

    the coils do not split, but i do know what you...

    the coils do not split, but i do know what you guys are referring to, i've cleaned those types of coils as well. i have cleaned those coils twice with the blue nu-calgon, very strong acid foaming...
  22. Replies
    32
    Views
    4,178

    no it was built 407c

    no it was built 407c
  23. Replies
    32
    Views
    4,178

    Trane Intellipak - High Pressure

    Looking for some advice. Trane intellipak's, two 40 ton and two 50 tons serving the building. R-407C. All units are having high-pressure trips causing the "compressor trip" diagnostic. I've been...
  24. Replies
    12
    Views
    1,678

    What service apps are you using with the Galaxy?

    What service apps are you using with the Galaxy?
  25. Replies
    12
    Views
    1,678

    What brand is it that you use?

    What brand is it that you use?