  1. Thread: Filter Dryers

    by KB Cool
    Replies
    16
    Views
    602

    I've never seen one on a goodman from the...

    I've never seen one on a goodman from the factory. Sounds like somebody messed up.
  2. Thread: Filter Dryers

    by KB Cool
    Replies
    16
    Views
    602

    Was it a york? They put them in the discharge...

    Was it a york? They put them in the discharge line right before the RV.
  3. Thread: High pressure

    by KB Cool
    Replies
    29
    Views
    958

    If condensor is clean. Spray some water on the...

    If condensor is clean. Spray some water on the condensor to allow it to run and bring the indoor load down. I have to do that out here sometimes when it's 115 out and 98 inside. Just too much load...
  4. Replies
    11
    Views
    285

    Should be a tech book in the back somewhere. Is...

    Should be a tech book in the back somewhere. Is the evap fan running?
  5. Maybe if he actually had a 12 ton unit instead of...

    Maybe if he actually had a 12 ton unit instead of a 10 ton it would work better.:grin2: OP do you have your racks set up properly intakes all aligned in front and exhausting out back? Unit return...
  6. Replies
    9
    Views
    431

    Sounds like the stat is configured for heat pump....

    Sounds like the stat is configured for heat pump. Turn it to cool and the OWB terminal energizes. :grin2:
  7. Just curious, why is 70 too warm for a data...

    Just curious, why is 70 too warm for a data center. My home PC runs fine when it's 78 in my house. What's the difference?
  8. Replies
    19
    Views
    737

    I wouldn't let that guy in the first video touch...

    I wouldn't let that guy in the first video touch my A/C with a 10 foot pole. :eek: I like my run caps mounted!
  9. Replies
    24
    Views
    660

    Viper's great and all but it wont do Sh!t on the...

    Viper's great and all but it wont do Sh!t on the real nasty ones.
  10. Replies
    11
    Views
    470

    I had one too. I replaced the board and the pin...

    I had one too. I replaced the board and the pin connector just in case. Problem went away.
  11. Replies
    24
    Views
    660

    This one here i just hosed it, time clock...

    This one here i just hosed it, time clock included. :grin2: It was the only way!
  12. Replies
    24
    Views
    660

    Uprights with the compressor on top sucks...

    Uprights with the compressor on top sucks rinsing, i usually just move any electronics out of the way and throw some towels down. Also have them unload the food and warn them about drips. The ones...
  13. Thread: Reasons R>HVAC

    by KB Cool
    Replies
    35
    Views
    2,158

    Good, i hate working on those Piece of Sh!ts! lol

    Good, i hate working on those Piece of Sh!ts! lol
  14. Replies
    39
    Views
    1,188

    What did the gas smell like? R-22, 410a, nitrogen...

    What did the gas smell like? R-22, 410a, nitrogen or what.................? :grin2:
  15. Replies
    23
    Views
    951

    The dye's fine it's the leak seal that ruins the...

    The dye's fine it's the leak seal that ruins the entire system.:eek:
  16. Thread: Runs good

    by KB Cool
    Replies
    79
    Views
    4,155

    I've seen that a couple times. One had a plugged...

    I've seen that a couple times. One had a plugged suction line dryer. The other a kink in the lineset. That one we tapped the indoor coil suction line and i think the pressure was at least 20 lbs...
  17. I know! I would like to hear from the original...

    I know! I would like to hear from the original poster to see if his customer declined his estimate to repair or replace and called another company to get it repaired for 40% less. Major wire repair...
  18. Nobody's flat out told him he's a rip-off. But,...

    Nobody's flat out told him he's a rip-off. But, on a repair like that with multiple items that need replaced. You gotta discount it some because your already there and into it. That board wouldn't...
  19. Replies
    58
    Views
    3,395

    Some of them have a LP switch. But, i doubt the...

    Some of them have a LP switch. But, i doubt the one you installed has one. But, even if it does it can still short cycle to death! :grin2:
  20. Replies
    58
    Views
    3,395

    You gotta at least build into your price a...

    You gotta at least build into your price a unfortunate call back. What happen if that goodman springs a leak and runs for 3 days because the lady's out of town and trashes the compressor. Now you...
  21. Replies
    58
    Views
    3,395

    I'm sure your prices will go up as you get more...

    I'm sure your prices will go up as you get more experience. It's a natural progression! :grin2:
  22. Replies
    193
    Views
    41,315

    He's afraid you might pay his license plate and...

    He's afraid you might pay his license plate and registration fee! :grin2:
  23. Replies
    26
    Views
    1,215

    No, they leave the evap fans running 24/7 to help...

    No, they leave the evap fans running 24/7 to help with icing. I've never seen it done any other way. I was thinking you were going to wire the clock to the 120v building outlet and then wire the unit...
  24. Replies
    26
    Views
    1,215

    No, it's done that way to keep the coil free of...

    No, it's done that way to keep the coil free of ice during the off cycle!
  25. Replies
    26
    Views
    1,215

    Isn't it better to have the evap fan running...

    Isn't it better to have the evap fan running during defrost?
  26. Replies
    26
    Views
    1,215

    Never done it that way. I've always powered up...

    Never done it that way. I've always powered up the clock and then ran the tstat through the normally closed contacts. That way you can choose what time a day to defrost like when the health inspector...
  27. Replies
    12
    Views
    2,590

    I guess the guy wanted to fix the leak then and...

    I guess the guy wanted to fix the leak then and now. Instead of buying a new accumulator. :confused:
    I'm sure it's rotted out on the bottom.
  28. Replies
    49
    Views
    9,162

    Come on guys when are you going to stop placing...

    Come on guys when are you going to stop placing blame on the tech and blame it on the motor manufacturer terrible design instead. I mean serious, do we really need a shaft that long and the two "run"...
  29. Replies
    42
    Views
    8,323

    Or a noise and vibration complaint!

    Or a noise and vibration complaint!
  30. Replies
    9
    Views
    806

    Being in industrial maintenance. You should have...

    Being in industrial maintenance. You should have noticed the problems yourself before it led to compressor failure! :grin2:
  31. Replies
    7
    Views
    658

    Next time put your gauges on it!

    Next time put your gauges on it!
  32. Replies
    50
    Views
    3,213

    My guess is the primary line voltage is hanging...

    My guess is the primary line voltage is hanging on by a thread as soon as he powered up the board it dropped out. Burnt to crisp wire nut in the junction box? Seen it many times with no load you can...
  33. Replies
    224
    Views
    12,424

    The guy can always call the manufacturers tech...

    The guy can always call the manufacturers tech support for help! I did it the other day when i had a exv not opening! Couldn't call the boss because he aint gonna know either! :grin2:
  34. Replies
    9
    Views
    677

    I highly doubt he has aux heat in phoenix. Very...

    I highly doubt he has aux heat in phoenix. Very few systems here do! Sounds to me like he caught it in defrost!
  35. Replies
    224
    Views
    12,424

    Those units don't have a O to power. Just a B....

    Those units don't have a O to power. Just a B. :grin2:
  36. Replies
    17
    Views
    1,180

    http://hvacissues.com/motors-and-ohms-law/

    http://hvacissues.com/motors-and-ohms-law/
  37. Replies
    19
    Views
    1,089

    Have them inject a dye capsule into your system....

    Have them inject a dye capsule into your system. Much more cost effective and simpler way to find a pesky leak.
  38. Replies
    13
    Views
    1,072

    Yeah, those things are nice. I got 2 arcadia...

    Yeah, those things are nice. I got 2 arcadia glass doors, a big bay window, and a regular window all facing west and the afternoon heat just pours in. One of those would be perfect over my masters...
  39. Replies
    13
    Views
    1,072

    I gotta get me some of those rolling...

    I gotta get me some of those rolling shutters.:grin2:
  40. Replies
    6
    Views
    520

    I've seen those! Where do you mount the thing and...

    I've seen those! Where do you mount the thing and is it easily replaceable?
  41. Replies
    32
    Views
    1,887

    I guess your lucky! The 2 scroll's that i saw...

    I guess your lucky! The 2 scroll's that i saw that were ruined by super seal would not kickover with a 521! Maybe i should have tried a hammer. Also, if the customer calls and said he now wants to...
  42. Replies
    32
    Views
    1,887

    Just curious! Were these recips or scrolls? I've...

    Just curious! Were these recips or scrolls? I've seen the junk running in recips for years. Although still leaking refrigerant but, compressor never locked.
  43. Replies
    60
    Views
    3,130

    Amazing how the Silver King rep didn't know the...

    Amazing how the Silver King rep didn't know the equipment he represents! That sucks!
  44. Replies
    60
    Views
    3,130

    Use andy schoen's cap tube program instead of...

    Use andy schoen's cap tube program instead of silverkings. It'll work! And use a 032 dryer. And make sure you don't have any desiccant beads floating around.
  45. Replies
    32
    Views
    1,887

    It is what it is! Keep replacing the coils! I'm...

    It is what it is! Keep replacing the coils! I'm not a fan of the stuff after seeing 2 newer scroll compressors lock up shortly after some idiot adds the stuff! Customer would have been better off...
  46. Replies
    32
    Views
    1,887

    Why ruin the entire system including the line set...

    Why ruin the entire system including the line set when all you need is a new evap coil? :eek:
  47. Replies
    22
    Views
    1,302

    Headmaster?

    Headmaster?
  48. Thread: Puzzled

    by KB Cool
    Replies
    22
    Views
    1,801

    Put a hard start on it!

    Put a hard start on it!
  49. Replies
    60
    Views
    3,130

    Throw a tap on the liquid and one on the...

    Throw a tap on the liquid and one on the discharge. That'll at least help you rule out the condensor being the culprit.
  50. No you can use the hopscotch method by starting...

    No you can use the hopscotch method by starting on the same line.