  1. Replies
    4
    Views
    393

    Check how much builder will charge then check a...

    Check how much builder will charge then check a local contractor. In my experience builders will tack on additional $$. Local climate is also important.
  2. Why is there a zoning board with only one stat...

    Why is there a zoning board with only one stat hooked to it?
  3. Thread: York piston

    by skapusci
    Replies
    9
    Views
    594

    Also, coils come with a piston.

    Also, coils come with a piston.
  4. Thread: York piston

    by skapusci
    Replies
    9
    Views
    594

    The condenser paper work will tell me if the...

    The condenser paper work will tell me if the piston is right or the coil paper work? btw these are just coils on furnaces. No air handlers.
  5. Thread: York piston

    by skapusci
    Replies
    9
    Views
    594

    York piston

    The piston that comes with the york condenser. Is it necessary to install with the unit or is it only for certain occasions. Coil is matching.
  6. Sticky: I started in the HVAC field when I was 19. My...

    I started in the HVAC field when I was 19. My friends dad owned a residential HVAC company, and he hired a group of house for the summer to help with installs. I was kept on for the next four years...
  7. Replies
    27
    Views
    1,229

    Honeywell Pro4000 come with jumper. Dont know why...

    Honeywell Pro4000 come with jumper. Dont know why it wasnt in there.
  8. Replies
    27
    Views
    1,229

    This wasnt internet bought or "some buddies"...

    This wasnt internet bought or "some buddies" installing. The installers typically only install ductwork, but were used for an a/C install due to the amount of them that day.
  9. Replies
    25
    Views
    3,764

    beautiful steaks

    beautiful steaks
  10. Thread: Soaking wet

    by skapusci
    Replies
    22
    Views
    2,033

    Is it possible to condition the space? Add a...

    Is it possible to condition the space? Add a supply and return in the sealed crawl space?
  11. Replies
    7
    Views
    857

    Don't try eating them

    Don't try eating them
  12. Replies
    13
    Views
    1,268

    We do an hourly rate after first hour. A charge...

    We do an hourly rate after first hour. A charge for showing up. Charge for parts and refrigerant per pound.
  13. If there is a window in the garage a window unit...

    If there is a window in the garage a window unit may help the situation after fixing some of the leakage problems.
  14. Replies
    84
    Views
    5,183

    Talk to your boss about it. You may find out it...

    Talk to your boss about it. You may find out it is the norm throughout the company. It is sad to say, but I have seen companies like that before.
  15. Replies
    27
    Views
    1,229

    It was no jumper on stat between RC and RH

    It was no jumper on stat between RC and RH
  16. Replies
    27
    Views
    1,229

    * jumper was not in stat *

    * jumper was not in stat *
  17. Replies
    27
    Views
    1,229

    Installers. Boss told me it was because the...

    Installers. Boss told me it was because the jumper was in the thermostat for RH and RC
  18. Replies
    27
    Views
    1,229

    Blower did not come on. Condenser did not come...

    Blower did not come on. Condenser did not come on. Connections were correct.
  19. Replies
    27
    Views
    1,229

    on a the furnace control board that is true

    on a the furnace control board that is true
  20. Replies
    27
    Views
    1,229

    on a the furnace control board that is true

    on a the furnace control board that is true
  21. Replies
    27
    Views
    1,229

    No y2 on condensing unit. Straight cool only Y...

    No y2 on condensing unit. Straight cool only Y and common. Condensing unit did not come on, so I assume no 24v?
  22. Thread: Low charge?

    by skapusci
    Replies
    10
    Views
    750

    try soapy water before other guy comes out. Also...

    try soapy water before other guy comes out. Also look for oil.
  23. Replies
    27
    Views
    1,229

    Trane Furnace NOthing when Call for cool

    Recently coworkers installed a 4 ton york straight cool condenser and 4 ton coil on Trane furnace. Furnace control board was set uo for two stage cooling. Had 1 heat 1 cool honeywell pro 4000 stat....