09-15-2012, 09:50 PM
Thread: Tea Kettle in a Trailer... Oh what fun.
by steamdrm- Replies
- 7
- Views
- 1,687
Looks like a Powerhouse rental trailer.
Looks like a Powerhouse rental trailer.
-
08-21-2012, 08:29 PM
Thread: Condensate Carryover
by steamdrm- Replies
- 14
- Views
- 1,263
Good evening all. It appears the culprit is an...
Good evening all. It appears the culprit is an intermitantly operating barometric bypass damper.Thanks for the comments & suggestions. Hopefully the problem is solved. Will replace the damper next...
-
08-15-2012, 07:58 PM
Thread: Condensate Carryover
by steamdrm- Replies
- 14
- Views
- 1,263
It does re-enter close to the return plenum....
It does re-enter close to the return plenum. thanks on the plexiglass tip.
-
08-15-2012, 07:57 PM
Thread: Condensate Carryover
by steamdrm- Replies
- 14
- Views
- 1,263
This is an air handler manufactured by "The First...
This is an air handler manufactured by "The First Company" that has an evap. coil upstream, or on the suction side of the fan, with a hydronic hot water heating coil on the pressure, or discharge...
-
08-15-2012, 01:23 PM
Thread: Condensate Carryover
by steamdrm- Replies
- 14
- Views
- 1,263
We took readings on the A/H return inlet, and the...
We took readings on the A/H return inlet, and the A/H outlet.
-
08-15-2012, 06:26 AM
Thread: Condensate Carryover
by steamdrm- Replies
- 14
- Views
- 1,263
No open air returns, but it does have a prior...
No open air returns, but it does have a prior existing Carrier barometric bypass damper off the supply duct. The damper shaft indicator shows closed, but it could be leaking through.
-
08-15-2012, 06:23 AM
Thread: Condensate Carryover
by steamdrm- Replies
- 14
- Views
- 1,263
The condensate line is in fact properly trapped....
The condensate line is in fact properly trapped. The coil is mounted below the fan and the fan velocity appears to be "sucking" or lifting the condensate off of the coil.
-
08-14-2012, 08:03 PM
Thread: Condensate Carryover
by steamdrm- Replies
- 14
- Views
- 1,263
Condensate Carryover
Good evening,
I replaced an existing 4 ton air/air heat pump with a 4 ton straight cool/ hot water hydronic coil air handler.
The new air handler sucks or pulls the condensation off of the...
Results 1 to 8 of 9