Search:

Type: Posts; User: joebear

Page 1 of 7 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    10
    Views
    751

    discharge r22

    discharge r22
  2. Replies
    10
    Views
    751

    im having similar issue with the thermistors,...

    im having similar issue with the thermistors, screen reading higher than gauge pressure,trimmed down but still 50 psi high,even with new thermistors
  3. Replies
    20
    Views
    1,228

    I agree on spider web inside pilot tube, only way...

    I agree on spider web inside pilot tube, only way to clean out is like said previously scrub out with light gauge wire
  4. Replies
    20
    Views
    1,869

    gas pressure 13" input, is this lp gas? if so...

    gas pressure 13" input, is this lp gas? if so outlet pressure should be aroung 10"
  5. Thread: Air compresdor

    by joebear
    Replies
    5
    Views
    623

    use nitrogen or co2 tanks

    use nitrogen or co2 tanks
  6. Thread: New tool

    by joebear
    Replies
    23
    Views
    2,104

    I got the flir tg165 from united refr. I love it...

    I got the flir tg165 from united refr. I love it for the price. I wish I could have spent more to get e series
  7. Replies
    18
    Views
    752

    I got it, called tech support and had to put in...

    I got it, called tech support and had to put in range and few other things
  8. Replies
    18
    Views
    752

    thank you guys, going to try to set up pid...

    thank you guys, going to try to set up pid parameters
  9. Replies
    18
    Views
    752

    looking over manual again on pid

    looking over manual again on pid
  10. Replies
    18
    Views
    752

    cant the vfd be programmed for maintaining proper...

    cant the vfd be programmed for maintaining proper static
  11. Replies
    18
    Views
    752

    vav unit running 3" w.c. with dampers wide open,...

    vav unit running 3" w.c. with dampers wide open, need to run at 1.5" w.c., that's not the problem, I cant figure out how to set vfd up to control static, literature is hard to understand
  12. Replies
    18
    Views
    752

    Schneider altivar atv212hd15n4

    Schneider altivar atv212hd15n4
  13. Replies
    18
    Views
    752

    old rtu adding vfd

    got an old trane 40t rtu, doing away with inlet guide vanes, installing vfd [shenider] and pressure transducer. how do I tell the vfd the amount of w.c. static I want to maintain, having trouble...
  14. Replies
    2
    Views
    641

    thank you tech23

    thank you tech23
  15. Replies
    2
    Views
    641

    carrier 38yda060

    carrier 38yda060 with fault code 2 blinks, fault code legend on door is faded what is 2 blinks
  16. Replies
    2
    Views
    446

    check for bad condenser motor or capacitor

    check for bad condenser motor or capacitor
  17. Thread: Stumped

    by joebear
    Replies
    22
    Views
    2,268

    no, it was a first for me

    no, it was a first for me
  18. Thread: Stumped

    by joebear
    Replies
    22
    Views
    2,268

    had a split heat pump with similar situation,...

    had a split heat pump with similar situation, after changing txv,and rev.valve it ended up being scroll compressor bad,scrolls leaking by
  19. cost,cheaper for tandem

    cost,cheaper for tandem
  20. Replies
    2
    Views
    968

    thank you so much dandyme

    thank you so much dandyme
  21. Replies
    2
    Views
    968

    48LDT006610da w/d

    hey I really need a wiring diagram for carrier 48ldt006610 just the gas heat side, thx
  22. spider web in manifold and or orifices

    spider web in manifold and or orifices
  23. Thread: pressure test

    by joebear
    Replies
    18
    Views
    3,648

    thanks for the reponse

    thanks for the reponse
  24. Thread: pressure test

    by joebear
    Replies
    18
    Views
    3,648

    pressure test

    repaired leak in 10 ton rtu,left 200 psi nitrogen,temp. at that time was 48 deg. going back tomorrow temp.supose to be in the teens, a little r22 was left in with nitrogen,will my pressures be lower...
  25. hey thx looks like jade may be easy retro

    hey thx looks like jade may be easy retro
  26. so silkbus sensor for my enthapy and different...

    so silkbus sensor for my enthapy and different one for mixed air?
  27. whats the silkbus sensor

    whats the silkbus sensor
  28. I need to retrofit econmiozer on a 10ton carrier,...

    I need to retrofit econmiozer on a 10ton carrier, want sensors do I need with the jade
  29. Replies
    25
    Views
    4,283

    any comments on the new h10pro model from...

    any comments on the new h10pro model from bacharach
  30. Replies
    2
    Views
    832

    carrier edge tstat e1 error code

    carrier dual fuel package 48xt0360903, changed 3 edge tstats in 3 years, anybody know of any problems
  31. Replies
    54
    Views
    10,676

    united ref.,nrp,beacon,whatever, has sold us out...

    united ref.,nrp,beacon,whatever, has sold us out to the Chinese,all this junk is junk!
  32. Replies
    54
    Views
    10,676

    while im here united ref.,nrp,beacon, what ever...

    while im here united ref.,nrp,beacon, what ever has sold us out to china,they should be ashamed for what they have done
  33. Replies
    54
    Views
    10,676

    yellow jacket only, nrp is china junk

    yellow jacket only, nrp is china junk
  34. Replies
    6
    Views
    1,236

    I love my testo 557's, I don't know why you guys...

    I love my testo 557's, I don't know why you guys hate testo so much
  35. Replies
    5
    Views
    848

    take backside panel off and you got it,unless...

    take backside panel off and you got it,unless shaft is whiddled down
  36. Replies
    36
    Views
    5,859

    when I started this thread I had in mind but...

    when I started this thread I had in mind but didn't say it right, analog meters



    when I started this thread my mind was on analog meters mostly, simpson 260, amprobe rs3, and analog temperature...
  37. Replies
    36
    Views
    5,859

    exactly, when we retire its all gone,they wont...

    exactly, when we retire its all gone,they wont know. im doing it for myself like a retrospect of my career
  38. are you sure this coil dosent have multiple...

    are you sure this coil dosent have multiple orifices feeding it,trane has problems with these clogging
  39. Replies
    36
    Views
    5,859

    go back to analog for a week

    just for fun why don't we all go back to analog gauges,amprobe,multimeter,and temperature meter for a week. I work with several young guys that never seen a real amprobe before. yall probably will...
  40. Replies
    76
    Views
    8,334

    what tricks do you guys have for replacing heat...

    what tricks do you guys have for replacing heat exchangers on larger tonnage sunlines like 15 tons
  41. Replies
    1
    Views
    734

    york prestige rtu

    has anyone installed the new York prestige exact fit rtu yet? any good or bad features?
  42. Thread: pneumatics

    by joebear
    Replies
    12
    Views
    1,569

    ok thanks,im in va. and most older buildings are...

    ok thanks,im in va. and most older buildings are designed to fail to heat,but I have seen 3 somewhat newer buildings fail to cool,never seen or heard of that
  43. Thread: pneumatics

    by joebear
    Replies
    12
    Views
    1,569

    pneumatics

    will somebody explain how most pneumatic blbgs fail to heat but some fail to cool
  44. Replies
    76
    Views
    8,334

    one trick I have done on the larger sunlines to...

    one trick I have done on the larger sunlines to get the heat exchanger out is to use a hydraulic portapower to spread the sheet metal walls apart so you can lift exchanger out
  45. Replies
    11
    Views
    2,412

    stay away from uei,i have heard bad things,i have...

    stay away from uei,i have heard bad things,i have the Bacharach insight and I like it a lot,easy to use
  46. Replies
    24
    Views
    3,518

    r.e. michels has them on sale with clamps for...

    r.e. michels has them on sale with clamps for $298.00
  47. Replies
    8
    Views
    1,641

    guess its time for the sman5

    guess its time for the sman5
  48. Replies
    12
    Views
    1,723

    check smoke detector and all pressure switch...

    check smoke detector and all pressure switch wires for rub thru to copper
  49. Replies
    6
    Views
    818

    York is the worst by far

    York is the worst by far
  50. Replies
    56
    Views
    10,050

    im going to digicool ak900 and bluvac!!!!!!!!!!

    im going to digicool ak900 and bluvac!!!!!!!!!!
Results 1 to 50 of 332