  1. Replies
    36
    Views
    1,670

    When crazy unexplainable things happen I look at...

    When crazy unexplainable things happen I look at the software embedded in a board cause all the mechanical operational parts I can prove work.
  2. Replies
    20
    Views
    1,221

    All of you are correct but we sleep 1/3 of the...

    All of you are correct but we sleep 1/3 of the time. So 33 % of the time we won't smell it and die if it's within our living space. Being alert and smelling is one thing being asleep and breathing it...
  3. Replies
    8
    Views
    573

    No never do this. The amp draw can vary based on...

    No never do this. The amp draw can vary based on many different operating conditions. You will be led down a very confusing road. Take poole headed mikey's suggestions and run with it. He is shooting...
  4. Replies
    8
    Views
    642

    yes it can you have the cooling ability.

    yes it can you have the cooling ability.
  5. No about everyone has forgotten to do that. If...

    No about everyone has forgotten to do that. If you have a problem address it otherwise you are ok.
  6. Replies
    14
    Views
    956

    A unit with no return? Doesn't sound good,...

    A unit with no return? Doesn't sound good, especially down there. Exactly how did the installer plan to dehumidify the space air? I've only seen it once and it was from a company known to do shady...
  7. Replies
    18
    Views
    2,181

    If the temp at the roll out switch isn't high...

    If the temp at the roll out switch isn't high enough to open it, change out the roll out switch. If your indoor blower runs like it should after heating stops place a piece of thread or anything...
  8. Replies
    26
    Views
    1,177

    If wired correctly a bad stat or w and y stat...

    If wired correctly a bad stat or w and y stat wires touching 24vac.
  9. Replies
    31
    Views
    1,631

    I would put it back as it was designed to...

    I would put it back as it was designed to operate. But that's just me. Some of my harder work came after I took the easy way too.
  10. Replies
    18
    Views
    855

    Thank You hvac69.

    Thank You hvac69.
  11. Replies
    18
    Views
    855

    I got you now. After removing the harness that...

    I got you now. After removing the harness that connects the J6 slot on the RTRM board to the J2 slot on the communication board I connect the J1 harness connector on the communication board to the...
  12. Replies
    18
    Views
    855

    The top left connection on the RTRM board is J6....

    The top left connection on the RTRM board is J6. Are you saying once I disconnect the harness that connects J6 on the RTRM board to J1 on the communication board i need to connect the wiring harness...
  13. Replies
    18
    Views
    855

    That's isn't possible. The harness on the...

    That's isn't possible. The harness on the communication board is connected to J1 it connects to the RTRM board at J6. If I remove the harness there will be nothing on J1 or J6. Check out my pic's....
  14. Replies
    18
    Views
    855

    635651635661

    635651635661
  15. Replies
    18
    Views
    855

    There's two I think they go to section J6. I'll...

    There's two I think they go to section J6. I'll look tomorrow if it stops raining and snap a couple of pic's.
  16. Replies
    18
    Views
    855

    HVAC69: There are two wiring harness's from the...

    HVAC69: There are two wiring harness's from the communication board to the RTRM board. Once I remove both wiring harness's that connect the two boards together which wiring harness connects to the...
  17. Replies
    18
    Views
    855

    I do not see how that is possible. If the...

    I do not see how that is possible. If the communication board remains connected then it will receive it's instructions to cycle on and off from Trane tracer summit software. I don't want that. I want...
  18. Replies
    18
    Views
    855

    The communication board mounted behind the RTRM...

    The communication board mounted behind the RTRM board has two wiring harness's connected to the RTRM board. I remove both connection at the RTRM board
    and connect my '3' wire Trane stat wires to...
  19. Replies
    18
    Views
    855

    I looked but never located what you stated. Do...

    I looked but never located what you stated. Do you have a link to it ? I imagine I would wire the three wire stat to the terminal strip and disconnect the wiring harness that connects the...
  20. Replies
    18
    Views
    855

    Taking off communications

    On a Trane Precedent RTU unit model YSC036E3RLA12000000000000. if I need to control the
    unit from the thermostat in the room instead of from communications, how do I do this?
    I suspect I unplug the...
  21. Thread: Cloudy ice

    by Ricky Dale
    Replies
    24
    Views
    2,884

    Flush your lines, have a good new filter and...

    Flush your lines, have a good new filter and clean your machine well. make sure your water isn't very cloudy before it enters the filter. A filter can only remove so much.
  22. Replies
    9
    Views
    2,102

    Possibly a short in the board from a poor design....

    Possibly a short in the board from a poor design. Unplug power to the board then apply power and see if it blows the fuse then. Or unplug all your control voltage leads and plug them in one at a time...
  23. Replies
    8
    Views
    1,350

    The few I've worked on the eye gets dirty and...

    The few I've worked on the eye gets dirty and can't send a beam across the top of the bin so it thinks the ice bin is full and blocking the beam.
  24. Replies
    3
    Views
    741

    Yes no luck on their site, I'll put the email...

    Yes no luck on their site, I'll put the email address in now. Thanks
  25. No. I know the Trane 1147 stat/sensor measures...

    No. I know the Trane 1147 stat/sensor measures the space temp in ohm's as well as the thumbwheel setting. What i'm asking is once the 517 board receives the ohm reading from the stat/sensor what...
  26. zone sensor temp/ 517 board conversion method.

    I have a question concerning Trane's 1147 zone temperature sensor. What's value reading does the sensor transmit to the 517 board for the 517 board to convert to a temperature so it can tell if the...
  27. Replies
    3
    Views
    741

    schmatic needed

    I get asked to work on an ice machine from time to time. it isn't my chosen interest but I would like know and clearly understand the sequence of operation
    of operation. We have Scotsman ice...