Search:

Type: Posts; User: FieldGen3

Search: Search took 0.00 seconds.

  1. Replies
    0
    Views
    133

    True TR2RRT-2S-2S

    Looking for a wiring diagram. Anybody have one?
  2. Replies
    3
    Views
    240

    Thanks for the suggestion. Yea I have been to...

    Thanks for the suggestion. Yea I have been to Alto shaam site and even called them to ask what they use. The tech support lady couldn't give me an exact part number but we were on the same page as...
  3. Replies
    3
    Views
    240

    Hose help please

    Hey guys, I need help finding a flexible water supply hose for a new Alto-Shaam CTP7-20E install. My lines will be 3/4" copper and the fitting on the machine is 3/4" MGHT stainless. Manufacturer...
  4. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    1,489

    Agreed... Been running a few days now with no...

    Agreed... Been running a few days now with no problems.
  5. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    1,489

    Update: based on the feedback I think this unit...

    Update: based on the feedback I think this unit was some sort of custom install. There are quick connects to separate the drop in cold pan (I called it a cold rail before) Yes the cold pan was...
  6. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    1,489

    This unit has a cold rail.

    This unit has a cold rail.
  7. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    1,489

    Heck if I know, but I'm guessing it is still at...

    Heck if I know, but I'm guessing it is still at the factory
  8. Thread: WTF Randell

    by FieldGen3
    Replies
    28
    Views
    1,489

    WTF Randell

    Salad bar cooler no worky. "Oh you're here to fix that thing? I've worked here for two years and it's never worked." Out of gas, schrader bubbles, tighten, vac and charge. It worky now. Only now it...
  9. Replies
    2
    Views
    668

    The temp control is definitely a knob and yes it...

    The temp control is definitely a knob and yes it is soldered directly to the control panel board. I think you answered my question I was just hoping it was a $20 chip vs a $2k+ board.
  10. Replies
    2
    Views
    668

    First time on Groen CC20-E

    We have a Groen Model# CC20-E Serial# C8948MS with an unresponsive cook temp control. I ran the diagnostics and when I get to the part where I have to turn the temp control knob one click at a time...
  11. Replies
    9
    Views
    771

    We have six like units in service. Typically if...

    We have six like units in service. Typically if one goes down and needs an extensive repair we swap the head out with a spare for as little down time as possible. Considering the parts removed I'm...
  12. Replies
    9
    Views
    771

    It would be rebuilt as a spare and it would...

    It would be rebuilt as a spare and it would definitely get new refrigerant when it is put back into service, but I would have a harder time ensuring multiple drier changes once it was. Maybe I can...
  13. Replies
    9
    Views
    771

    Resurrecting Ice-o-Matic

    We have an old ice-o-matic that was abandoned sitting in the back of our shop. I think it's an ICE1007HR, 404a, 208 3PH. It's been sitting there for 6+ months with the evaporator, txv and drier...
  14. Replies
    32
    Views
    2,860

    If a puller isn't available and turning the shaft...

    If a puller isn't available and turning the shaft doesn't free it, I try pushing the blade towards the motor and then sanding the area was the hub met the shaft.
  15. Replies
    23
    Views
    1,866

    Has anybody had luck using an ETC in this...

    Has anybody had luck using an ETC in this application? Jamb the sensor in the coil, set-point 18, diff 19. You might be able to experiment with the set-points and find a sweet spot.
  16. Replies
    12
    Views
    989

    Doesn't it suck in a bunch of air while you do...

    Doesn't it suck in a bunch of air while you do that? Even if you run the vacuum longer after the switch why not avoid introducing non-condensables by making the switch while still positive? Or you...
  17. Replies
    12
    Views
    989

    How are you removing your liquid line hose while...

    How are you removing your liquid line hose while the unit is under vacuum?
  18. Thread: condenser

    by FieldGen3
    Replies
    2
    Views
    527

    http://www.cpsproducts.com/images/products/xs/MT69...

    http://www.cpsproducts.com/images/products/xs/MT69_CPS-molecular-transformator-recovery_31.jpg

    Made me think of this... But google disagrees
  19. Replies
    133
    Views
    8,888

    Thanks for all the feedback. I agree that...

    Thanks for all the feedback. I agree that subcooling as a charging method on systems with a receiver is useless.
  20. Replies
    4
    Views
    1,797

    I need a rig that can fit in the bottom section...

    I need a rig that can fit in the bottom section of a rack and hoist out a 2 hp semi with only 2 foot clearance or less.
  21. Replies
    133
    Views
    8,888

    Thanks, I'll stop worrying about it.

    Thanks, I'll stop worrying about it.
  22. Replies
    133
    Views
    8,888

    Yea I feel good about that system it just made me...

    Yea I feel good about that system it just made me think in general that water cooled condensers could easily be overcharged. I guess it doesn't really matter as long as the receiver can hold it?
  23. Replies
    133
    Views
    8,888

    How can I tell if walk in is over charged?

    So I had to change a LLSV the other day. Pump the unit down, changed the valve, pulled vacuum, opened the king valve and started checking a few things out. Glass was clear, superheat was 3, so I...
  24. Replies
    5
    Views
    580

    I'm only guessing at what you are describing but...

    I'm only guessing at what you are describing but in general cable ties just keep bundles of wire neatly out of the way. As long as they aren't going to get damaged by a fan or a flame I wouldn't...
  25. Replies
    3
    Views
    450

    So far I've been lucky that my facility mostly...

    So far I've been lucky that my facility mostly uses the same drive for everything. I have a cheat sheet of the parameters and control wire terminations. On the high voltage side I've had bad...
  26. Replies
    5
    Views
    580

    I wouldn't worry about it as long as the wires...

    I wouldn't worry about it as long as the wires are out of the way.
  27. Replies
    5
    Views
    580

    Push mount cable ties

    Push mount cable ties
  28. Replies
    8
    Views
    2,313

    Good to know. Are you satisfied with the gauges...

    Good to know. Are you satisfied with the gauges otherwise?
  29. Replies
    8
    Views
    2,313

    Thanks for the reply. The picture of those gauges...

    Thanks for the reply. The picture of those gauges makes them look a little more durable than others. Should I not worry so much about them bouncing around in the truck? I am thinking of getting two...
  30. Replies
    8
    Views
    2,313

    Boots for 3-1/2" liquid filled gauges

    Looking into getting the 3-1/2" liquid filled gauges (YJ part #'s 49513 & 49514). Will the 3-1/8" gauge boots (49190) fit these?
  31. I have a couple questions about these steps: 1....

    I have a couple questions about these steps:
    1. After draining the oiling and replacing the plug, does running the pump for 3 to 4 seconds without oil in it risk damaging the pump?
    2. How does the...
  32. Replies
    18
    Views
    4,789

    Thanks for the explination. It's starting to make...

    Thanks for the explination. It's starting to make a lot more sense.
  33. Replies
    18
    Views
    4,789

    Refrigerant Delta T Across Evaporator

    I saw a journeyman take the temperature rise of the refrigerant across the evaporator of a walk in cooler. First temp was taken between the outlet of the txv and the distributor, second temp was...
  34. Thread: vacum setup

    by FieldGen3
    Replies
    102
    Views
    16,562

    Can someone explain the best way to break the...

    Can someone explain the best way to break the vacuum in these setups? My concern is damaging the micron gauge during a triple evac or charging. It doesn't look like you can isolate just the gauge if...