  1. Thread: Metasys Comm

    by Refugio
    Replies
    1
    Views
    642

    Metasys Comm

    Excuse me if my english is not pretty clear...
    we have in mi job yesterday a black out and now...I turn on the metasys
    program cause the pc went out with the black out...
    but i noticed that there...
  2. Replies
    10
    Views
    1,167

    This rooftop does not use Klixon It is sending...

    This rooftop does not use Klixon
    It is sending a signal of 24 volts from a relay call K4 till a Contactor which is activating the second cond motor but the contactor is ok and theres ever voltage...
  3. Replies
    10
    Views
    1,167

    I have some units YCD and TCD and they have the...

    I have some units YCD and TCD and they have the second condensor fan off and the first one with a fan cycling control.. I have in this particular unit low head but It seems that the problem should...
  4. Replies
    10
    Views
    1,167

    Ill change the OAT sensor and see what result...

    Ill change the OAT sensor and see what result but i cooled this sensor before and turned the compressors off before that stopped the fan that i think that should be control thru the K4 relay...
  5. Replies
    10
    Views
    1,167

    Thank you Id seen in the manual but i got...

    Thank you
    Id seen in the manual but i got problems with icing in the evaporators and I saw at the morning that this particular rooftop unit at 10C or so.. it has that condenser fan motor working...
  6. Replies
    10
    Views
    1,167

    Trane RTU second stage cycle

    I want that somebody explain me....
    how a trane rooftop like YCD241....controls into the second stage the fan cycling..is output voltage travels thru the K4 from the relliatel to a contactor
    where...
  7. Replies
    11
    Views
    2,281

    whats the recommendation for a trane rooftop...

    whats the recommendation for a trane rooftop unit to be recycling a fan motor
    is it 95 / 65
  8. Replies
    11
    Views
    1,424

    Thanks Ill do it like that

    Thanks
    Ill do it like that
  9. Replies
    11
    Views
    1,424

    Thank you I guess thats the better way.

    Thank you
    I guess thats the better way.
  10. Replies
    11
    Views
    1,424

    the air stream leaving the dryer is too high i...

    the air stream leaving the dryer is too high i got an alarm coming from that point
    the pressure seems to be ok, the air is coming from a compressor, the whole
    system feeds actuators, air guns and...
  11. Replies
    11
    Views
    1,424

    Refrigerated air dryer

    I need to know whats going on into a Hankinson Dryer
    its boiling point is 38 F with R-134a I set the low pressure as what is said in the datasheet (31 psig) but the air temperature is out of...