Search:

Type: Posts; User: mardoman

Page 1 of 5 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    16
    Views
    4,042

    Thanks for your replies. As I stated I've got...

    Thanks for your replies.

    As I stated I've got a 18 year old restaurant with 18 year old equipment and they keep increasing the load by increasing sales and adding more appliances.

    I would love...
  2. Thread: Leaking Trane

    by mardoman
    Replies
    6
    Views
    1,240

    Thanks Guys. That repair coupling may do it. The...

    Thanks Guys.
    That repair coupling may do it. The aluminum tubing is chaffed on the bottom row of the condenser. It was caused by the suction line coming from the reversing valve. The 3/8 insultube...
  3. Replies
    16
    Views
    4,042

    I appreciate your input guys but I'm still not...

    I appreciate your input guys but I'm still not getting it :confused:

    Maybe I should start by giving you my situation.

    Small southern coastal town. Growing population. Lots of tourists....
  4. Thread: Leaking Trane

    by mardoman
    Replies
    6
    Views
    1,240

    Leaking Trane

    My customer has a TWA 048 Heat pump that has a leak on the aluminum condenser tubing.
    I've never been able to solder or epoxy aluminum tubing. Does Trane have a factory repair kit? Do any Trane...
  5. Replies
    16
    Views
    4,042

    Thanks for your replies. I'm confused...

    Thanks for your replies.
    I'm confused :confused: Maybe you all can explain it so I may understand this.

    one ton = 12000 btu......... is there a difference between High temp and A/C based on the...
  6. Replies
    16
    Views
    4,042

    BRE2-0750-TFC replacement

    What is the most correct replacement scroll compressor for a BRE-2-0750-TFC.

    Two of my local wholesalers and Copeland advise using a ZB58KC-TF5.
    After looking at the performance charts for both I...
  7. Replies
    15
    Views
    1,532

    K Fridge I hear ya brother, I agree. The dude at...

    K Fridge I hear ya brother, I agree. The dude at Copeland was adamant about opening the TXV all the way. I backed it off 2 turns on my final adjustment.

    The dudes at Copeland had to leave early...
  8. Replies
    15
    Views
    1,532

    I agree with you Markettech. Today the box...

    I agree with you Markettech.

    Today the box was at + 40 when I did the restart.
    This box has lots of bread in it and that seems to really impose a heavy load on the system. Another thing that...
  9. Replies
    15
    Views
    1,532

    Superheat...Bingo! You guys are correct............

    Superheat...Bingo! You guys are correct......... yea, way too high. This was on a warm start-up.

    Consulted with Copeland.... I mean Emerson Climate Technologies. They were very helpful. They first...
  10. Replies
    15
    Views
    1,532

    Can of Whoopa$$

    A Walk-in Freezer I installed back in '99 quit on me about 3 weeks ago on a Saturday nite. The remote can compressor was running, but the suction was high @ 50 psig and the head @ 150 psig and it...
  11. Replies
    64
    Views
    5,123

    I have never been a fan of nugget ice on a...

    I have never been a fan of nugget ice on a fountain/dispenser.
    They are ALWAYS going to freeze up, or rather, the ice WILL fuse together in the hopper.
    ............But we have 10 stores with the...
  12. Replies
    12
    Views
    1,047

    Ice, Petrified gray door gaskets? I try to...

    Ice,

    Petrified gray door gaskets? I try to remove the door and use the restaurants' can wash area and clean the entire door assembly with hot water.
    The restaurants around here are supposed to...
  13. Replies
    18
    Views
    1,780

    Guys, I always thought the finish timer is (...

    Guys,

    I always thought the finish timer is ( was ) a 10 minute timer.....7 minutes freeze, 3 minute harvest for example. I must need a new watch.

    A bad compressor????:rolleyes: WTF? It is...
  14. Replies
    16
    Views
    2,090

    Dice, I believe the older Tranes' require a...

    Dice,

    I believe the older Tranes' require a thermostat interface board ( $ 150.00 )
    in order to hook up a standard thermostat ( $ 40.00 ).

    That OEM programable zone sensor (T-stat) is $$$ ....
  15. Replies
    18
    Views
    1,780

    Coolerfixer, You haven't missed anything....

    Coolerfixer,

    You haven't missed anything. These older Scotsmans don't make as thick of a cube as the current CM3.

    The headmaster seems to be lame. The head pressure needs to be at 240 psig....
  16. Replies
    6
    Views
    721

    I need some help here on the coast. You may be...

    I need some help here on the coast. You may be interested.
    Please check out my post from 12-13-06
  17. Replies
    9
    Views
    2,340

    I'm on the coast and have a position you guys may...

    I'm on the coast and have a position you guys may be interested in.
    Please see my post from 12-14-06
  18. Gee, I thought my chicken salad comment was...

    Gee, I thought my chicken salad comment was harsh.:D
  19. Replies
    21
    Views
    1,496

    I may have seen this before. I have...

    I may have seen this before. I have CRS.:confused: It may be your thermisters telling you ya got low discharge temp. Maybe a leak. Look at TXV cap tube chaffing on a refrigerent line behind...
  20. Replies
    5
    Views
    1,876

    If I recall this correctley an island hood open...

    If I recall this correctley an island hood open on all four sides requires 150 cfm per sq.ft.
    A hood against a wall require 100 cfm per sq.ft.( open on three sides ).
    Using your size : 17 x 4 = 68...
  21. Bless your heart! I guess things must be slow in...

    Bless your heart! I guess things must be slow in the great White North... eh?

    I had to service the same model unit yesterday, same pressures.
    All I had to do was degrease & rinse the condenser.
    ...
  22. Replies
    0
    Views
    444

    WI Combo and a Custard Machine for Sale

    Please look at my thread in the junkyard forum for details :)

    Merry Christmas
  23. Replies
    1
    Views
    866

    Custard Machine for Sale

    Ross 3 Barrell with remote C-Units (3)
    1998 model 208/230v/3
    Tecumseh hermetic 208/230v/3 ; R404 w/ U.L. outdoor housings


    Equipment in V.G. condition
    Available now in Wilmington, NC 28405...
  24. Replies
    0
    Views
    610

    WI Combo for sale

    Masterbilt Cooler/Freezer Combo
    12' x 27' x 7.5' Floorless; Outdoor w/Durolast
    Galvalume, Int. & Ext. 12' Partition
    Installed 4-00
    2-36 x 78 doors with peep holes, 14" x 14"; Left hand hinged
    ...
  25. Replies
    7
    Views
    1,752

    Wiz, I've only got 28 pages of paper. Call them...

    Wiz,
    I've only got 28 pages of paper. Call them for e-mail.
    The control board is covered in the manual.
    The restaurant that uses this, don't program, they just hit quick chill.

    What I've...
Results 1 to 25 of 124
Page 1 of 5 1 2 3 4