    3 contractors sized it when I got independant...

    3 contractors sized it when I got independant quotes. You saying all three fudged the numbers?

    Also the previous furnace was an 85k, but yet another contractor. AND the original furnace was 80k....
  2. Replies
    31
    Views
    5,321

    Hence, I ask and want to know how they work. But...

    Hence, I ask and want to know how they work. But I don't want to shorten the lifespan of my furnace due to excessive cycles. The quest continues.

    Not intimidated at all and not afraid to...
  3. Replies
    31
    Views
    5,321

    Average temp for this time of year is 20 - 25....

    Average temp for this time of year is 20 - 25. Min temps are in the middle teens. It was warmer this morning, around 30.

    1600 sq foot ranch built in the 60s with average insulation for the...
  4. Replies
    31
    Views
    5,321

    So your saying the display on the thermostat is...

    So your saying the display on the thermostat is incorrect. The temperature it displays is right at setpoint, granted it could be a few tenths low. According to you, it could be less. Not...
  5. Replies
    31
    Views
    5,321

    Definitely not over sized. My Robertshaw/Invensys...

    Definitely not over sized. My Robertshaw/Invensys Insight 2-stage thermostat works it just fine. My thoughts are that it just has a very small dead-band since it tries to maintain a constant temp...
  6. Thread: Tridium Time

    by y2kjackal
    Replies
    6
    Views
    703

    In your local library\tridiumx\lib\muxDemux,...

    In your local library\tridiumx\lib\muxDemux, there is a program object called DateTimeDiscreteComponents. It is an SNS file that you copy and paste into your logic bundle. Is this the info you are...
  7. As Softtail said, Fit Ops is the rep for...

    As Softtail said, Fit Ops is the rep for Invensys/TAC in the Pittsburgh area. When Invensys sold off all of their branch offices, the Pgh office was sold to LW Straw in Johnstown. LW Straw then sold...
  8. Replies
    31
    Views
    5,321

    Color me as another confused one for CPH....

    Color me as another confused one for CPH. :confused: I always thought it was Cycles Per Hour. In the cooling portion of the setup manual, it calls it that. Or is it different for cooling? :confused:...
  9. Replies
    23
    Views
    1,936

    I know I probably missed some suggestions and/or...

    I know I probably missed some suggestions and/or comments, but something else to look into if not already suggested. Check with the humidifier manufacturer and see if they have some info on the...
  10. Replies
    13
    Views
    2,323

    Be aware that the Patton Model 285 may need some...

    Be aware that the Patton Model 285 may need some tweaks to get it to work properly. They do have a Model 285-BC that works better with less fuss. Also watch out for the red and green wires flipping...
  11. Thread: signal

    by y2kjackal
    Replies
    14
    Views
    1,945

    Cheapest and easiest way would be what cntrlman...

    Cheapest and easiest way would be what cntrlman suggested. A PC anywhere type setup. If Signal is on XP already and you have XP or 2000, remote desktop is free (I think).
  12. Replies
    11
    Views
    1,496

    I would think the licensing scheme used by...

    I would think the licensing scheme used by Tridium in R2 would not allow another Integrator (Invensys rep or not) to work with the JACE. So an Invensys office or rep may not be able to instal the...
  13. Replies
    6
    Views
    1,002

    I'd be curious to find out more about an OPC...

    I'd be curious to find out more about an OPC server for Network 8000. If you relocate it, let me know.
  14. Replies
    4
    Views
    1,133

    You can use LonMaker to commission these, but you...

    You can use LonMaker to commission these, but you need Workplace Tech to program them. Depending on the revision of firmware in the controller and WP Tech, you might be able to upload the program....
  15. Replies
    13
    Views
    2,366

    Sometimes the local controls companies put on...

    Sometimes the local controls companies put on classes, too. Check in with the Johnson, Honeywell, Siemens, and Invensys controls office (or rep) and see if they offer classes.
  16. Replies
    8
    Views
    1,401

    Does it have a timer for this or is the design...

    Does it have a timer for this or is the design such that an off cycle functions as the defrost? If on a timer or limit, could the defrost element be burnt out?

    What about being level. If the water...
  17. Replies
    2
    Views
    589

    3 ton fan motors are a breeze. Just connect wires...

    3 ton fan motors are a breeze. Just connect wires start fan, place blades on fan, and insert into slot where the fan goes. You may need to check rotation. That is best done with the fingers on your...
  18. Replies
    23
    Views
    1,429

    Just my two cents here. Does the building have...

    Just my two cents here. Does the building have general exhaust? The system design may take in account that a certain amount of general exhaust, toilet fans, equipment room exhaust, etc. be running....
  19. Thread: Relays

    by y2kjackal
    Replies
    2
    Views
    581

    Double post? See other relay post.

    Double post? See other relay post.
  20. Thread: Relays

    by y2kjackal
    Replies
    3
    Views
    608

    Most relays will have a marking on the relay...

    Most relays will have a marking on the relay which shows which pins or blades are contacts (Common, Normally Closed, or Normally open)and which are coil as a diagram. You could use a meter and check...
  21. Replies
    21
    Views
    9,554

    I feel for you zandman. Trying to find all the...

    I feel for you zandman. Trying to find all the cut wires can be a chore.

    Like Control Man said the MZIIs can be programmed to run like a satellite from the GCM or as a logical controller. Most of...
  22. Replies
    6
    Views
    733

    If anyone knows of a 24 VAC one, could you post...

    If anyone knows of a 24 VAC one, could you post info?
  23. Replies
    10
    Views
    1,259

    Not exactly sure what you are asking and I don't...

    Not exactly sure what you are asking and I don't know anything about the MP580.

    But, LNS is echelon's LON network management scheme. Not sure what LNS exactly stands for, but must be something to...
  24. Replies
    21
    Views
    9,554

    zandman, It is possible to communicate with...

    zandman,
    It is possible to communicate with other microzones using a connection at the thermostat. Problem is, the ASD bus needs to be run to the stat. You will also need a RS-232 to RS-485...
  25. Replies
    21
    Views
    9,554

    Zandman, Barbara has not worked for the company...

    Zandman,
    Barbara has not worked for the company since they quit selling lanterns and coolers. /kidding mode = off

    Do a search of this forum and you will see a thread or two about passwords for...
Results 1 to 25 of 40
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event