  1. Replies
    10
    Views
    881

    replace valves,leak lock will hold until next guy...

    replace valves,leak lock will hold until next guy comes along and removes caps and doesnt reapply leak lock.
  2. ive never seen a condenser freeze while in...

    ive never seen a condenser freeze while in cooling mode,your evap. coil is what freezes and your suction line will freeze back to the condenser.several things can cuase this.
  3. Replies
    14
    Views
    5,323

    you're unit is working like its supposed to put...

    you're unit is working like its supposed to put those gauges on ebay!
  4. Replies
    19
    Views
    3,021

    definitely talk to owner,wouldnt settle for...

    definitely talk to owner,wouldnt settle for repair they would have to buy me a new one.
  5. Replies
    12
    Views
    1,145

    no problems with mastercool.

    no problems with mastercool.
  6. their definitely blowing smoke about the...

    their definitely blowing smoke about the "lifetime" warranty,thanks for the heads up.hope you get your problem figured out.
  7. Replies
    2
    Views
    537

    definitely need more than 400 sq. inches of...

    definitely need more than 400 sq. inches of return for 3 ton system.
  8. Replies
    5
    Views
    796

    the tighter the system the better.not something...

    the tighter the system the better.not something thats hard to do
  9. try replacing the fan?

    try replacing the fan?
  10. thats odd about the warranty,amana salesman at...

    thats odd about the warranty,amana salesman at our shop just last week he said they were giving lifetime warranty and would replace entire unit and pay labor to changeout.
  11. Replies
    4
    Views
    552

    get you a P.T. chart and learn how temperature...

    get you a P.T. chart and learn how temperature effects pressures thats a good start.each refrigerant will have a different pressure temp relationship
  12. Replies
    7
    Views
    834

    Tempature Drop Across Coil

    Tempature Drop Across Coil
  13. Replies
    29
    Views
    2,780

    the oxygen in the line causes the oxidation the...

    the oxygen in the line causes the oxidation the nitrogen is a dead gas and displaces the oxygen no air no oxidation means less problems down the road
  14. Replies
    32
    Views
    2,410

    This Guy Is Exactly Why We Have Diy Rules On This...

    This Guy Is Exactly Why We Have Diy Rules On This Site,get The Message?
  15. Amen Brother!!!!

    Amen Brother!!!!
  16. Replies
    23
    Views
    1,725

    didnt say anything about 4" said to multiply...

    didnt say anything about 4" said to multiply circumference of pipe times 4 then add 2" for lap and yes this will work for any size pipe.we wrap 14" pipe everyday and it works perfect,no rule of thumb...
  17. Replies
    23
    Views
    1,725

    we run alot of metal pipe we multiply size of...

    we run alot of metal pipe we multiply size of pipe times 4 then add 2" for lap 3.14 sounds tight if you smash insulation youre defeating the purpose.
  18. Replies
    30
    Views
    2,238

    some cheese with that whine,maybe a box of...

    some cheese with that whine,maybe a box of kleenex and a diaper
  19. Replies
    3
    Views
    1,538

    www.wrightsoft.com

    www.wrightsoft.com
  20. daiken

    daiken systems are designed to run up to three heads on one condensor.they they are low cfm systems designed to run all the time and maintain one temp regardless of outdoor temp.what you're wanting...
  21. liquid line is highside during heating and...

    liquid line is highside during heating and cooling, flow of refrigerant just changes directions.suction line becomes discharge line in heating mode.during cooling inside coil is evaporator outside...
  22. Thread: gasheat

    by mississippi
    Replies
    1
    Views
    321

    gasheat

    looking for literature for gas heat any suggestions,also dual fuel systems,thanks
  23. Replies
    25
    Views
    3,809

    A psc motor already has a start capacitor in...

    A psc motor already has a start capacitor in series with the start windings.by adding a potential relay you're not going to help yourself.if you suspect your compressor needs help starting yes a hsc...
  24. show me somewhere that 80% of homes being built...

    show me somewhere that 80% of homes being built aren't being built by some big developer, they build them as cheap as they can.for the other 20% they may get their hood ducted to the outside.guess it...
  25. you're right wasn't thinking about the high...

    you're right wasn't thinking about the high velocity,thanks