Search:

Type: Posts; User: crab master

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. Replies
    13
    Views
    500

    Turns out the modbus card was bad, but now that I...

    Turns out the modbus card was bad, but now that I have a new one it isn't working either.

    Uniflair is owned by APC/Schneider now so they have better documentation on their site -...
  2. Replies
    6
    Views
    900

    http://www.bapihvac.com/content/uploads/2011/01/14...

    http://www.bapihvac.com/content/uploads/2011/01/14646_ins_BA_EA1.pdf

    http://www.bapihvac.com/
  3. Replies
    38
    Views
    1,884

    One I didn't program, then it's someone else's...

    One I didn't program, then it's someone else's problem. :grin2:

    For ones I've worked with so far I like the TAC Xenta 700 series the most (LON), but I don't like the proprietary...
  4. Replies
    12
    Views
    1,132

    Rolo would disagree. Also I don't think Siemans...

    Rolo would disagree. Also I don't think Siemans can talk proprietary comms.

    Welcome to the site.
  5. Replies
    20
    Views
    577

    I must of gotten a hell of a deal on my...

    I must of gotten a hell of a deal on my touchscreens. Oh there the same as grgjohno mentioned.
  6. Briefing the document and going back to the OP,...

    Briefing the document and going back to the OP, IMO the most versatile setup would be CO2 and IAQ or just VOC.

    http://www.greystoneenergy.com/webcura/files/245717_air300_spec.pdf...
  7. Interesting concept. Wouldn't the supply air be...

    Interesting concept. Wouldn't the supply air be just as mixed as the return air and even more so once you mix in outside air? Possibly with VAV's closing down/going to a minimum position there may...
  8. Replies
    48
    Views
    3,268

    FWIW - I just got done installing a wireless...

    FWIW - I just got done installing a wireless network about a month ago and I am pretty happy with the results so far. Granted only doing temperature monitoring at this point, but it was nice how...
  9. Replies
    6
    Views
    527

    I'd suggest a small UPS or other power...

    I'd suggest a small UPS or other power conditioning/protection device. I'd assume the UPS solved ac-inc/Mike's issue as the last time he was on the site was a day after he posted in this thread....
  10. Replies
    12
    Views
    405

    As stated previously it may make more sense to go...

    As stated previously it may make more sense to go with a gateway if the brand of equipment has such. We've done a number with Cat, Detroit Diesel, others and with a gateway you can get so much more...
  11. Replies
    15
    Views
    606

    If I remember right you also really liked this -...

    If I remember right you also really liked this - http://www.opensystemsproducts.com/MODERN/Itemdesc.asp?ic=NRC1C-01&eq=&Tp=

    I'd appreciate a PM as well.
  12. Replies
    2
    Views
    219

    I used to have greater respect for Belimo until...

    I used to have greater respect for Belimo until they sold us a bunch, like over 150 actuators, that were labeled wrong by the factory. We installed every single one of them and didn't realize they...
  13. Have you emailed their tech support/looked on...

    Have you emailed their tech support/looked on their forums? http://csimn.com/CSI_pages/tour6.html

    I haven't worked with that controller, but emailing tech support they were generally back to me...
  14. Replies
    4
    Views
    250

    It would take at least a couple 511's. To follw...

    It would take at least a couple 511's. To follw rules more like 6, but if done with care one could do 2-3.
  15. These were pretty easy to run -...

    These were pretty easy to run - http://us.idec.com/Catalog/ProductSeries.aspx?SeriesName=IDEC_SmartRelay&FamilyName=Programmable_Relays
    Don't recall cost but it seemed reasonable. I see they have...
  16. Replies
    4
    Views
    250

    I don't know Trend, but I would think it would be...

    I don't know Trend, but I would think it would be more cost effective to just have the customer buy the TAC Vista Workstation license and just add to that. Granted you said the client doesn't want...
  17. Replies
    2
    Views
    263

    The first one, less to wire. :grin2: Either...

    The first one, less to wire. :grin2:

    Either would be fine, it's just the 2nd one it is hard to see the details. Also I'd recommend using either larger dots on wires that are going to the same...
  18. Replies
    12
    Views
    345

    We use the APC BMS - Battery Monitoring System. ...

    We use the APC BMS - Battery Monitoring System. We've had some problems with false alarms on Thermal Runaways, but I believe I heard it was due to poor connections and some crimp issues on certain...
  19. Pretty decent overall but I gotta say I hate it...

    Pretty decent overall but I gotta say I hate it when people get their greasy fingers all over in the sticky electrical tape. It just makes it come unraveled that much faster. Pull out an inch,...
  20. Replies
    13
    Views
    500

    Definitely plugged in to serial port, same...

    Definitely plugged in to serial port, same location as our Stulz units, only those have lon cards. I don't know the part number off hand on the modbus card.
    Stulz units also have Carel...
  21. Replies
    2
    Views
    204

    What about a simple pressure transmitter? No...

    What about a simple pressure transmitter?

    No sure if they are looking for minor breaks, but a major break you'd have a pressure loss.
  22. Replies
    13
    Views
    500

    Well no go on this, got a scanner and nothing...

    Well no go on this, got a scanner and nothing matched up. At first I though I was able to match up the # of starts, which isn't even in the list, but when I went back later to recheck they no longer...
  23. Replies
    6
    Views
    604

    I hope to make it next year and hopefully see...

    I hope to make it next year and hopefully see everyone then, unless in a training class somewhere.

    I checked out the DG stuff a few years back, but that was as far as I got.
  24. Replies
    48
    Views
    3,268

    The USB thought is a good idea, I may look into...

    The USB thought is a good idea, I may look into this closer, but we also need something we can read live data from at the time as well.
  25. Replies
    48
    Views
    3,268

    Bringing this back up as I am looking to...

    Bringing this back up as I am looking to implement a wireless solution for recording load data prior to the control system being built. Basically building and unit operation prior to TI.
    Just need...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4