Search:
Type: Posts; User: atozsvc
Search: Search took 0.01 seconds.
-
05-03-2012, 01:28 AM
Thread: My new Testo 550
by atozsvc- Replies
- 44
- Views
- 2,400
I have the testo 550 and the displays is not...
I have the testo 550 and the displays is not completly. And I wqas brought it on line.Want it service under warrenty.Where I have to sent .Hope someone can help me here.mr.Dan Wong.Thankyou.Can I...
-
11-02-2010, 02:03 AM
Thread: commercial bradford waterheater
by atozsvc- Replies
- 8
- Views
- 1,195
Right that is the control modual, have to by pass...
Right that is the control modual, have to by pass the y and back wiring at the plug which at the buttery motor plug.THX ALL
-
10-30-2010, 04:20 AM
Thread: commercial bradford waterheater
by atozsvc- Replies
- 8
- Views
- 1,195
They said it is the control broad
They said it is the control broad
-
10-28-2010, 12:57 PM
Thread: commercial bradford waterheater
by atozsvc- Replies
- 8
- Views
- 1,195
THX
THX
-
10-26-2010, 02:12 AM
Thread: commercial bradford waterheater
by atozsvc- Replies
- 8
- Views
- 1,195
Called factory pro already. Life is meaningless...
Called factory pro already.
Life is meaningless without learning.This site is help each other. -
10-25-2010, 12:09 AM
Thread: commercial bradford waterheater
by atozsvc- Replies
- 8
- Views
- 1,195
commercial bradford waterheater
bradford commercial water heater m#L100d1993n. The top butterfly not open so there is no hot water.The spark modual is good when I by-passed the wiring.But it can not control the temp.Just over...
-
10-11-2010, 12:54 AM
Thread: I wanna be the best
by atozsvc- Replies
- 12
- Views
- 738
Thank you Iemeister ,Rocket and others
Thank you Iemeister ,Rocket and others
-
10-11-2010, 12:43 AM
Thread: walkin freezer
by atozsvc- Replies
- 12
- Views
- 1,143
THX for your years help
THX for your years help
-
10-09-2010, 03:06 AM
Thread: walkin freezer
by atozsvc- Replies
- 12
- Views
- 1,143
How I check the efficiency of the this hermatic...
How I check the efficiency of the this hermatic compressor,normally I use the front seat method to test compressor.THX
-
10-08-2010, 11:32 PM
Thread: walkin freezer
by atozsvc- Replies
- 12
- Views
- 1,143
Icemeister and friends Your right the valve is...
Icemeister and friends
Your right the valve is kt 43 rzp compressor# ava2490 zxt r404a.
Start 9 am this morning,till 12 noon try to adjust the exp. Up date is weather 80 sunny discharge #225... -
10-08-2010, 03:38 AM
Thread: walkin freezer
by atozsvc- Replies
- 12
- Views
- 1,143
walkin freezer
Walkin have not work over yr.The freezer fan motor turn on when it is start,the fan terminator should be defective.Run over an hour,inside temp about 50 degree.
Evaporator coil just frost at frout... -
10-08-2010, 12:41 AM
Thread: Manufacturer Rant
by atozsvc- Replies
- 22
- Views
- 1,114
wrong page
wrong page
-
10-08-2010, 12:39 AM
Thread: Manufacturer Rant
by atozsvc- Replies
- 22
- Views
- 1,114
walkin freezer tubing
Walkin over yr not been used.Start it this afternoon. The fan turn on when it start, the fan terminator should be defective.Anyway wait for over an hour. The walkin not cold enough only about 50...
-
10-08-2010, 12:14 AM
Thread: uhhh haaa chain of events
by atozsvc- Replies
- 2
- Views
- 446
wal mart
ecklfmkf tyesting
-
06-21-2010, 08:59 PM
Thread: whirlpool gd5shaxlq02 ice maker
by atozsvc- Replies
- 1
- Views
- 532
bk-live wt-neutral br-water valve gr-ground
bk-live
wt-neutral
br-water valve
gr-ground -
04-29-2010, 01:35 AM
Thread: icemeisters birthday
by atozsvc- Replies
- 23
- Views
- 699
Happy another good year
Happy another good year
-
03-18-2010, 01:11 AM
Thread: walkin cooler
by atozsvc- Replies
- 18
- Views
- 938
Try the kickstart it may release it
Try the kickstart it may release it
-
03-18-2010, 12:35 AM
Thread: Evaporator fan blowing water
by atozsvc- Replies
- 15
- Views
- 1,468
Hot day around 75 degree.r 404 suction at...
Hot day around 75 degree.r 404 suction at compressor temp.6 '' 44 degree 52#pressure it should be 27 superheat.At 36 cooler'
The left side fan and the middle fan plate rusty and blowing water. -
05-06-2009, 01:57 AM
Thread: Blodget oven help..
by atozsvc- Replies
- 5
- Views
- 836
A good idea,wrap it in the hand.Thanks
A good idea,wrap it in the hand.Thanks
-
05-06-2009, 01:54 AM
Thread: american standard package
by atozsvc- Replies
- 0
- Views
- 246
american standard package
M#ycc048f3mobc.Looking for the control broad #tnc1634, is it no longer aviable?
-
05-06-2009, 01:45 AM
Thread: Coffin/island freezer icing up
by atozsvc- Replies
- 11
- Views
- 1,370
Is the feezer's fan should be running during...
Is the feezer's fan should be running during defrost,can someone tell me this that is the way .
-
04-28-2009, 08:40 PM
Thread: Happy B Day icemeister
by atozsvc- Replies
- 10
- Views
- 380
GOOD LUCK GOOD HEALTH AND GOD BLESS YOU.
GOOD LUCK GOOD HEALTH AND GOD BLESS YOU.
-
04-28-2009, 08:38 PM
Thread: Knee surgery and HVAC techs
by atozsvc- Replies
- 20
- Views
- 1,034
I fell from 17 feet and brok my pateller.I took...
I fell from 17 feet and brok my pateller.I took off 6-7 month for recover
-
04-27-2009, 10:29 PM
Thread: Happy B Day icemeister
by atozsvc- Replies
- 10
- Views
- 380
HAPPY BIRTHDAY
HAPPY BIRTHDAY
-
04-23-2009, 10:07 PM
Thread: GE M# GSS25LGMAWW
by atozsvc- Replies
- 7
- Views
- 466
appliance parts store.Welcome any time.
appliance parts store.Welcome any time.
Results 1 to 25 of 166